Dengue remains a major global public health concern, highlighting the need for rapid and sensitive methods for the early detection of dengue virus biomarkers. In the present study, a finite element model for the detection of dengue nonstructural protein 1 (NS1) using an interdigitated electrode (IDE)-based impedimetric biosensor was developed in COMSOL Multiphysics. The proposed sensor consists of gold IDEs coated with an antibody-based biorecognition layer and immersed in a conductive aqueous sample medium. Antibody-NS1 binding was modeled using the Langmuir adsorption isotherm. Frequency-domain simulations were used to examine the impedance response over a range of NS1 concentrations from 0 to 1000 ng/cm³. The results showed that the simulated impedance magnitude decreased with increasing NS1 concentration and excitation frequency. At 10 MHz, the normalized impedance response increased rapidly at low NS1 concentrations and gradually approached saturation at higher concentrations. A linear fit to three simulated concentration points (1-3 ng/cm³) yielded a normalized response slope of 0.9223%/(ng/cm³) (R² = 0.9963), providing a preliminary characterization of the model-predicted low-concentration response. These findings demonstrate the potential of computational modeling for characterizing the predicted electrical response of an IDE-based impedimetric NS1 biosensor, providing a basis for sensor optimization and future experimental validation. The reported sensitivity and concentration-dependent responses are simulation-based predictions and have not been experimentally validated.

Related

  1. Electrochemical detection of hepatitis B virus DNA: a biosensor based on MnO2/MWCNT/AgNPs composite material
    Yuzhen Zhu, Ying Huang, Nicole Jaffrezic-Renault +2
    PolyhedronPeer-reviewedLicence not statedGeneral chemistryHAL
  2. Miniaturized biosensor platforms for early detection of neurodegenerative diseases and their potential for clinical translation
    İnci Uludağ Anıl, Buse Sancaklı, Nicole Jaffrezic-Renault +2
    Discover ElectrochemistryPeer-reviewedCC BY-NC-ND 4.0Full textGeneral chemistryHAL
  3. An electrochemical biosensor based on antifouling conductive hydrogel for umami detection in complex fish matrices
    Mengjie Qin, Yuanyuan Luo, Feng Hong +6
    Food Chemistry: XPeer-reviewedCC BY-NC-ND 4.0Full textAnalytical chemistryPMC
  4. Cardiolipin-Based Electrochemical Biosensor for Non-treponemal Antibody Detection Using Screen-Printed Electrodes: A Proof-of-Concept Study
    Duane da Silva Moraes, Bruna Ferri Serafini, Felipe Longaray Kadel +5
    ACS OmegaPeer-reviewedCC BY 4.0Full textGeneral chemistryCrossrefPMC
  5. Portable and wireless microfluidic impedance sensor functionalized with MnCoPBA@MoS2 nanocomposite screen-printed gold electrodes for on-site bacteria detection
    Muhammad Anwar, Adil Khan, Saddique khalid +6
    Microchemical JournalPeer-reviewedLicence not stated6 citedAnalytical chemistryOpenAlex
BibTeX
@article{alzahrani2026comsolbased,
  title = {{COMSOL-Based Impedance and Sensitivity Analysis of an Interdigitated Electrode Biosensor for Dengue NS1 Detection.}},
  author = {Saleh I Alzahrani},
  journal = {Biosensors},
  year = {2026},
  month = nov,
  doi = {10.3390/bios16110621},
  url = {https://europepmc.org/article/MED/43082516},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - COMSOL-Based Impedance and Sensitivity Analysis of an Interdigitated Electrode Biosensor for Dengue NS1 Detection.
AU  - Saleh I Alzahrani
PY  - 2026
DA  - 2026/11/01
JO  - Biosensors
DO  - 10.3390/bios16110621
UR  - https://europepmc.org/article/MED/43082516
AB  - Dengue remains a major global public health concern, highlighting the need for rapid and sensitive methods for the early detection of dengue virus biomarkers. In the present study, a finite element model for the detection of dengue nonstructural protein 1 (NS1) using an interdigitated electrode (IDE)-based impedimetric biosensor was developed in COMSOL Multiphysics. The proposed sensor consists of gold IDEs coated with an antibody-based biorecognition layer and immersed in a conductive aqueous sample medium. Antibody-NS1 binding was modeled using the Langmuir adsorption isotherm. Frequency-domain simulations were used to examine the impedance response over a range of NS1 concentrations from 0 to 1000 ng/cm³. The results showed that the simulated impedance magnitude decreased with increasing NS1 concentration and excitation frequency. At 10 MHz, the normalized impedance response increased rapidly at low NS1 concentrations and gradually approached saturation at higher concentrations. A linear fit to three simulated concentration points (1-3 ng/cm³) yielded a normalized response slope of 0.9223%/(ng/cm³) (R² = 0.9963), providing a preliminary characterization of the model-predicted low-concentration response. These findings demonstrate the potential of computational modeling for characterizing the predicted electrical response of an IDE-based impedimetric NS1 biosensor, providing a basis for sensor optimization and future experimental validation. The reported sensitivity and concentration-dependent responses are simulation-based predictions and have not been experimentally validated.
SN  - 2079-6374
ER  -