Skip to content
DraconiticResearch
Search Sources API
194,161 studies31 sourcesUpdated 41 min ago
PreprintCC BY 4.0arXiv

Photon Calibration Techniques for High Resolution Cryogenic Detectors

Abstract

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector's resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector's performance will violate these assumptions, biasing the calibration. Finally, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

Versions

Related

  1. Enhanced micrometre spatial resolution and usable photon flux for hybrid pixel detectors via deep-learning-based X-ray localization
    Xiangyu Xie, Anna Bergamaschi, Martin Brückner +30
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  2. Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment
    N Schermer, H Abele, G Angloher +57
    HALPreprintLicence not statedApplied physics & instrumentationHigh-energy & particle physicsHAL
  3. Diffusive Description of Superconducting Single-Photon Detectors Using Quantum Mechanics
    Krzysztof Pomorski, Eryk Halubek
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  4. Cryogenic Optoelectronic Characterization of InGaAsP LEDs for Low-Energy Detector Calibration
    Muad Ghaith, Wolfgang Rau, Philippe Di Stefano +4
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  5. Demonstration of a cryogenic, switchable electron source for low-temperature detector calibration
    D. A. Bennett, M. Borghesi, P. Campana +17
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
BibTeX
@misc{matava2026photon,
  title = {{Photon Calibration Techniques for High Resolution Cryogenic Detectors}},
  author = {William J. Matava and Michael R. Williams},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2605.24116},
  eprint = {2605.24116},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2605.24116},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Photon Calibration Techniques for High Resolution Cryogenic Detectors
AU  - William J. Matava
AU  - Michael R. Williams
PY  - 2026
DA  - 2026/10/29
PB  - arXiv
DO  - 10.48550/arxiv.2605.24116
UR  - https://arxiv.org/abs/2605.24116
AB  - Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector's resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector's performance will violate these assumptions, biasing the calibration. Finally, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.