Abstract
Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector's resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector's performance will violate these assumptions, biasing the calibration. Finally, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.
Versions
Related
- Enhanced micrometre spatial resolution and usable photon flux for hybrid pixel detectors via deep-learning-based X-ray localization
- Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment
- Diffusive Description of Superconducting Single-Photon Detectors Using Quantum Mechanics
- Cryogenic Optoelectronic Characterization of InGaAsP LEDs for Low-Energy Detector Calibration
- Demonstration of a cryogenic, switchable electron source for low-temperature detector calibration
BibTeX
@misc{matava2026photon,
title = {{Photon Calibration Techniques for High Resolution Cryogenic Detectors}},
author = {William J. Matava and Michael R. Williams},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2605.24116},
eprint = {2605.24116},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2605.24116},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Photon Calibration Techniques for High Resolution Cryogenic Detectors
AU - William J. Matava
AU - Michael R. Williams
PY - 2026
DA - 2026/10/29
PB - arXiv
DO - 10.48550/arxiv.2605.24116
UR - https://arxiv.org/abs/2605.24116
AB - Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector's resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector's performance will violate these assumptions, biasing the calibration. Finally, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.
ER -