Thomson Scattering Measurement of 1 keV Electron Temperature on Lawson Machine 26
Abstract
LM26 is a magnetized target fusion experiment built to demonstrate compressional heating of a plasma with a collapsing solid lithium liner. We report the design of a Thomson scattering diagnostic for LM26 and measurements from the LMC-12 compression shot where an electron temperature of 1090 ± 40 eV was measured with high confidence. The LM26 Thomson scattering diagnostic can measure temperature during compression at 8 times and 2 spatial points. Access limitations restricted the design to narrow f/30 views, and a forward scattering configuration with scattering angles < 20deg. The small solid angle of the scattered light view is largely compensated for by the 10 times increase in the density during compression to > 1020m−3. Measuring at a small scattering angle significantly narrows the Thomson spectral broadening of the laser line. The narrow spectrum (1030-1063 nm) is advantageous for the design of optical components and to minimize noise from plasma background light. UKAEA polychromators specialized for small broadening measurements were used to analyze the scattered light. Results are also presented for an uncompressed plasma preceding LMC-12. Stray light was not a significant source of error. This design provides a strong design basis for Thomson scattering systems on future LM26 configurations.
Related
- Temporal Weight-Position Mapping: time-resolved parameter dominance of electron dynamics in nonlinear Thomson scattering
- Comment on arXiv:2608.29450: "First Measurement of Solar Neutrinos through Elastic Neutrino-Electron Scattering at the keV Scale"
- Improvement of Electron Cyclotron Emission Radiometer Towards Real-Time Temperature Measurement in the WEST tokamak
- First Measurement of Solar Neutrinos through Elastic Neutrino-Electron Scattering at the keV Scale
- Photoionization rates of oxygen and nitrogen at 800 nm measured by Thomson coherent microwave scattering
BibTeX
@misc{carle2026thomson,
title = {{Thomson Scattering Measurement of 1 keV Electron Temperature on Lawson Machine 26}},
author = {P. Carle and S. Edwards and X. Feng and A. Froese and M. Greenwood and A. Lee and M. Reynolds and A. Rudy and J. Sanchez Rojo and M. Schellenberg-Beaver and R. Svihra and R. Tingley and R. Zindler and M. Maslov},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2610.11769},
eprint = {2610.11769},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2610.11769},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Thomson Scattering Measurement of 1 keV Electron Temperature on Lawson Machine 26
AU - P. Carle
AU - S. Edwards
AU - X. Feng
AU - A. Froese
AU - M. Greenwood
AU - A. Lee
AU - M. Reynolds
AU - A. Rudy
AU - J. Sanchez Rojo
AU - M. Schellenberg-Beaver
AU - R. Svihra
AU - R. Tingley
AU - R. Zindler
AU - M. Maslov
PY - 2026
DA - 2026/10/08
PB - arXiv
DO - 10.48550/arxiv.2610.11769
UR - https://arxiv.org/abs/2610.11769
AB - LM26 is a magnetized target fusion experiment built to demonstrate compressional heating of a plasma with a collapsing solid lithium liner. We report the design of a Thomson scattering diagnostic for LM26 and measurements from the LMC-12 compression shot where an electron temperature of 1090 ± 40 eV was measured with high confidence. The LM26 Thomson scattering diagnostic can measure temperature during compression at 8 times and 2 spatial points. Access limitations restricted the design to narrow f/30 views, and a forward scattering configuration with scattering angles < 20deg. The small solid angle of the scattered light view is largely compensated for by the 10 times increase in the density during compression to > 10^20m^−3. Measuring at a small scattering angle significantly narrows the Thomson spectral broadening of the laser line. The narrow spectrum (1030-1063 nm) is advantageous for the design of optical components and to minimize noise from plasma background light. UKAEA polychromators specialized for small broadening measurements were used to analyze the scattered light. Results are also presented for an uncompressed plasma preceding LMC-12. Stray light was not a significant source of error. This design provides a strong design basis for Thomson scattering systems on future LM26 configurations.
ER -