Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 54 min ago
Peer-reviewedCC BY-NCJournal of International Medical Research

Clinical performance of i-gel and classic laryngeal mask airway in different head positions in patients aged ≥75 years: A prospective randomized study

  1. 1Department of Anesthesiology and Reanimation, Sultan 2. Abdulhamid Han Training and Research Hospital,
  2. 2Department of Anesthesiology and Reanimation, ,

Abstract

Objective Supraglottic airway devices are alternatives to endotracheal intubation under general anesthesia. However, their performance in older patients remains understudied, particularly in different head positions. Methods This prospective randomized controlled study included 120 patients aged ≥75 years undergoing elective urologic surgery. Patients were randomly allocated into four groups based on the device type and head position during insertion: (a) i-gel with neutral head position; (b) i-gel with right head rotation; (c) classic laryngeal mask airway with neutral head position; and (d) classic laryngeal mask airway with right head rotation. The primary outcome was the insertion time. Secondary outcomes included insertion attempts, oropharyngeal leak pressure, and perioperative variables, which were assessed in patients with successful device placement. Results The overall insertion success rate was 94.2% (113/120). The i-gel was associated with a significantly shorter insertion time and higher oropharyngeal leak pressure than the classic laryngeal mask airway (both p = 0.001). Two-way factorial analysis revealed that device type significantly influenced insertion time and oropharyngeal leak pressure, whereas head position and device-by-head position interaction exerted no significant effects. No significant differences were observed in the number of insertion attempts, fiberoptic view scores, peak airway pressure, recovery times, hemodynamic variables, or perioperative and postoperative complications. Conclusions In patients aged ≥75 years undergoing elective surgery, the i-gel was associated with a shorter insertion time and higher oropharyngeal leak pressure than the classic laryngeal mask airway. Head position did not significantly influence insertion time, oropharyngeal leak pressure, or peak airway pressure. These findings suggest that airway device selection exerts a greater impact on supraglottic airway performance than head position, whereas the i-gel may offer practical advantages in selected clinical settings. Trial registration : ClinicalTrials.gov ( https://clinicaltrials.gov ), Identifier: NCT07027293, registered on 27 May 2025.

Related

  1. A prospective, randomized study comparing different therapeutic modalities for acute adenoviral conjunctivitis
    Anchal Thakur, Surya P Sharma, Poonam Chauhan +6
    Indian Journal of OphthalmologyPeer-reviewedCC BY-NC-SAFull textGeneral medicineDOAJ
  2. Acute effects of different percussive massage frequencies on shoulder proprioceptive recovery and upper-limb performance in male artistic gymnasts: a randomized crossover trial
    Hao Wang, Sihan Jiao, Maiwulanjiang Tuerhongjiang +2
    Frontiers in physiologyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMCEurope PMC
  3. Comparison of Two Polypropylene Meshes With Different Areal Densities in Open Lichtenstein Repair of Primary Inguinal Hernia: A Prospective, Quasi-Randomized Controlled Trial.
    Ekansh H Singh, Raj Kumar Singh, Ashish K Chaudhary +3
    CureusPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
  4. Effects of ultrasound-guided superior trunk block with different ropivacaine volumes on hemidiaphragmatic paralysis and analgesic efficacy in patients undergoing arthroscopic rotator cuff repair: a study protocol for a prospective randomized controlled trial {1a}
    Lei Cao, Tingyan Wang, Kepu Zhang +3
    TrialsPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  5. Feasibility of Laryngeal Mask Airway insertion during continuous chest compressions in neonatal resuscitation: a randomized crossover simulation study
    Cengizhan Yavuz, Emel Gündüz, Gözen Öksüz
    Frontiers in pediatricsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{yilmaz2026clinical,
  title = {{Clinical performance of i-gel and classic laryngeal mask airway in different head positions in patients aged ≥75 years: A prospective randomized study}},
  author = {Yadigar Yilmaz and Dondu Dilek Yamac and Ferda Yilmaz Inal and Suheyla Abitagaoglu},
  journal = {Journal of International Medical Research},
  year = {2026},
  month = nov,
  doi = {10.1177/03000605261505180},
  url = {https://doi.org/10.1177/03000605261505180},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Clinical performance of i-gel and classic laryngeal mask airway in different head positions in patients aged ≥75 years: A prospective randomized study
AU  - Yadigar Yilmaz
AU  - Dondu Dilek Yamac
AU  - Ferda Yilmaz Inal
AU  - Suheyla Abitagaoglu
PY  - 2026
DA  - 2026/11/10
JO  - Journal of International Medical Research
DO  - 10.1177/03000605261505180
UR  - https://doi.org/10.1177/03000605261505180
AB  - Objective Supraglottic airway devices are alternatives to endotracheal intubation under general anesthesia. However, their performance in older patients remains understudied, particularly in different head positions. Methods This prospective randomized controlled study included 120 patients aged ≥75 years undergoing elective urologic surgery. Patients were randomly allocated into four groups based on the device type and head position during insertion: (a) i-gel with neutral head position; (b) i-gel with right head rotation; (c) classic laryngeal mask airway with neutral head position; and (d) classic laryngeal mask airway with right head rotation. The primary outcome was the insertion time. Secondary outcomes included insertion attempts, oropharyngeal leak pressure, and perioperative variables, which were assessed in patients with successful device placement. Results The overall insertion success rate was 94.2% (113/120). The i-gel was associated with a significantly shorter insertion time and higher oropharyngeal leak pressure than the classic laryngeal mask airway (both p = 0.001). Two-way factorial analysis revealed that device type significantly influenced insertion time and oropharyngeal leak pressure, whereas head position and device-by-head position interaction exerted no significant effects. No significant differences were observed in the number of insertion attempts, fiberoptic view scores, peak airway pressure, recovery times, hemodynamic variables, or perioperative and postoperative complications. Conclusions In patients aged ≥75 years undergoing elective surgery, the i-gel was associated with a shorter insertion time and higher oropharyngeal leak pressure than the classic laryngeal mask airway. Head position did not significantly influence insertion time, oropharyngeal leak pressure, or peak airway pressure. These findings suggest that airway device selection exerts a greater impact on supraglottic airway performance than head position, whereas the i-gel may offer practical advantages in selected clinical settings. Trial registration : ClinicalTrials.gov ( https://clinicaltrials.gov ), Identifier: NCT07027293, registered on 27 May 2025.
SN  - 1473-2300
SN  - 0300-0605
ER  -