Validation of a Commercially Available Non-Woven Fabric Electrode for Mouse Electroretinography

  1. 1Kawasaki Medical School

Abstract

Purpose: To evaluate the performance and usability of a commercially available non-woven fabric electrode as a cost-effective and user-friendly alternative to standard corneal contact lens electrodes for recording murine electroretinograms. Methods: Using a paired design, full-field electroretinograms were recorded in the same mice using the commercially available non-woven fabric electrode and a conventional contact lens electrode. Key parameters evaluated included (1) stability of baseline noise, (2) dark-adapted intensity-response curves (0.01-100 cd{middle dot}s{middle dot}m-2), (3) light-adapted intensity-response curves (3-100 cd{middle dot}s{middle dot}m-2), (4) 20-Hz and 30-Hz flicker responses, (5) extended recordings targeting slow c-wave kinetics under dark-adapted conditions, and (6) inter-eye consistency via bilateral simultaneous recordings. Results: Eliminating the need for viscous lubricants, the non-woven fabric electrode simplified placement on the cornea, alignment, and re-application. It yielded a-wave and b-wave amplitudes and peak times comparable or superior to those obtained with standard contact lens electrodes. Notably, during prolonged recordings, the non-woven fabric electrode yielded significantly larger c-wave amplitudes while maintaining equivalent baseline noise stability. Bilateral simultaneous recordings demonstrated high inter-eye correlation and low variability of measurements between contralateral eyes. Conclusions: The non-woven fabric electrode provides high-quality, reproducible electroretinographic recordings comparable to (and for c-waves superior to) those obtained using standard corneal contact lens electrodes. This method facilitates standardized data acquisition and improves inter-laboratory reproducibility of murine electroretinography. Translational Relevance: By reducing financial and technical barriers, this non-woven fabric electrode offers an alternative to specialized recording setups, improving experimental throughput and efficiency in ophthalmic research.

Related

  1. Marked variation in the bacterial microbiota of commercially produced Greek kefir products revealed by full-length 16S rRNA gene sequencing
    Despina Vougiouklaki, Panagiotis Lamprou, Nikos Mouhtouris +7
    Frontiers in MicrobiologyPeer-reviewedCC BY 4.0Full textMicrobiologyCrossrefEurope PMC
  2. Evaluation of locally available poultry feed resources and their nutritional value in Tigray Region, Ethiopia
    Dawit Mamo Zegeye, Assen Ebrahim, Mewael Kiros Assefa
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textZoology & animal behaviourCrossref
  3. Batch Effect Correction to Enhance Utility of a Publicly Available ALS Proteomics Dataset
    G. Cooper, I. Oh, P. Payne +2
    bioRxivPreprintAll rights reservedFull textBioinformatics & computational biologybioRxiv
  4. Polystyrene-associated pulmonary fibrosis: a summary based on the available evidence and prospects
    Shifang Sang, Yushuai Liu, Hui Zhao +4
    Frontiers in immunologyPeer-reviewedCC BYFull textImmunologyEurope PMC
  5. Heterologous Expression and Characterization of a Novel Polygalacturonase (DdpgA) from Dickeya dadantii DCE-01 and Its Application in Bioscouring of Ramie Fabric
    Ke Shi, Qi Yang, Guoguo Xi +8
    PolymersPeer-reviewedCC BY 4.0Systems & synthetic biologyCrossref
BibTeX
@misc{ishizuka2026validation,
  title = {{Validation of a Commercially Available Non-Woven Fabric Electrode for Mouse Electroretinography}},
  author = {Y. Ishizuka and H. Kamao and J. Matsuda},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.07.757191},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.07.757191v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Validation of a Commercially Available Non-Woven Fabric Electrode for Mouse Electroretinography
AU  - Y. Ishizuka
AU  - H. Kamao
AU  - J. Matsuda
PY  - 2026
DA  - 2026/10/07
PB  - bioRxiv
DO  - 10.64898/2026.10.07.757191
UR  - https://www.biorxiv.org/content/10.64898/2026.10.07.757191v1
AB  - Purpose: To evaluate the performance and usability of a commercially available non-woven fabric electrode as a cost-effective and user-friendly alternative to standard corneal contact lens electrodes for recording murine electroretinograms. Methods: Using a paired design, full-field electroretinograms were recorded in the same mice using the commercially available non-woven fabric electrode and a conventional contact lens electrode. Key parameters evaluated included (1) stability of baseline noise, (2) dark-adapted intensity-response curves (0.01-100 cd{middle dot}s{middle dot}m-2), (3) light-adapted intensity-response curves (3-100 cd{middle dot}s{middle dot}m-2), (4) 20-Hz and 30-Hz flicker responses, (5) extended recordings targeting slow c-wave kinetics under dark-adapted conditions, and (6) inter-eye consistency via bilateral simultaneous recordings. Results: Eliminating the need for viscous lubricants, the non-woven fabric electrode simplified placement on the cornea, alignment, and re-application. It yielded a-wave and b-wave amplitudes and peak times comparable or superior to those obtained with standard contact lens electrodes. Notably, during prolonged recordings, the non-woven fabric electrode yielded significantly larger c-wave amplitudes while maintaining equivalent baseline noise stability. Bilateral simultaneous recordings demonstrated high inter-eye correlation and low variability of measurements between contralateral eyes. Conclusions: The non-woven fabric electrode provides high-quality, reproducible electroretinographic recordings comparable to (and for c-waves superior to) those obtained using standard corneal contact lens electrodes. This method facilitates standardized data acquisition and improves inter-laboratory reproducibility of murine electroretinography. Translational Relevance: By reducing financial and technical barriers, this non-woven fabric electrode offers an alternative to specialized recording setups, improving experimental throughput and efficiency in ophthalmic research.
ER  -