Heavy Metal Toxicity Following Metal‐on‐Metal Knee Arthroplasty Revision Surgery: A Case Report
- 1Department of Orthopedics Trauma and Plastic Surgery University of Leipzig Leipzig Germany uni-leipzig.de
- 2Department of Internal Medicine III Division of Nephrology University of Leipzig Leipzig Germany uni-leipzig.de
- 3Department of Nuclear Medicine University of Leipzig Leipzig Germany uni-leipzig.de
Abstract
Metallosis is a rare complication; hence, previous investigations regarding this topic are restricted to case reports. Little has been published on metallosis following total knee arthroplasty (TKA). We report the case of a patient who experienced cobalt and chromium metallosis 14 years following TKA‐revision surgery. She developed a variety of symptoms that could indicate systemic clinical toxicity, including skin redness, headaches, irritability, cognitive decline, and sleep disturbances. Replacing the prosthesis, utilizing chelation therapy, and trials of double‐filtration plasmapheresis reduced the serum level of heavy metals upon regular laboratory follow‐ups, leading to a temporary relief of symptoms. The presence of confounding factors and other concomitant conditions makes the distinction between systemic metal exposure and suspected systemic clinical toxicity very challenging.
Related
- Case Report: Successful needle revision of an encapsulated bleb following PAUL glaucoma Implant surgery in a pediatric patient
- Primary Total Knee Arthroplasty Using Revision-Type Stems for Distal Femoral Bone Compromise Following Previous Fracture Fixation: A Report of Two Cases and Narrative Review
- Local Anesthetic Systemic Toxicity Following High-Volume Ropivacaine, Epinephrine, Clonidine, and Ketorolac (RECK) Infiltration During Total Knee Arthroplasty: A Case Report.
- Prognosis of 1st time revision due to pain following primary total hip arthroplasty - a nationwide cohort study from the Danish Hip Arthroplasty Register
- Independent Predictors of Major Wound Complications Requiring Revision Surgery Following Lumbar Spine Surgery: A Large Single-Center Cohort Study
BibTeX
@article{assaf2026heavy,
title = {{Heavy Metal Toxicity Following Metal‐on‐Metal Knee Arthroplasty Revision Surgery: A Case Report}},
author = {Mohamad Assaf and Alexander Merckens and Solveig Tiepolt and Tom Lindner and Andreas Roth},
journal = {Case Reports in Orthopedics},
year = {2026},
month = nov,
doi = {10.1155/cro/3777088},
url = {https://doi.org/10.1155/cro/3777088},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Heavy Metal Toxicity Following Metal‐on‐Metal Knee Arthroplasty Revision Surgery: A Case Report
AU - Mohamad Assaf
AU - Alexander Merckens
AU - Solveig Tiepolt
AU - Tom Lindner
AU - Andreas Roth
PY - 2026
DA - 2026/11/09
JO - Case Reports in Orthopedics
DO - 10.1155/cro/3777088
UR - https://doi.org/10.1155/cro/3777088
AB - Metallosis is a rare complication; hence, previous investigations regarding this topic are restricted to case reports. Little has been published on metallosis following total knee arthroplasty (TKA). We report the case of a patient who experienced cobalt and chromium metallosis 14 years following TKA‐revision surgery. She developed a variety of symptoms that could indicate systemic clinical toxicity, including skin redness, headaches, irritability, cognitive decline, and sleep disturbances. Replacing the prosthesis, utilizing chelation therapy, and trials of double‐filtration plasmapheresis reduced the serum level of heavy metals upon regular laboratory follow‐ups, leading to a temporary relief of symptoms. The presence of confounding factors and other concomitant conditions makes the distinction between systemic metal exposure and suspected systemic clinical toxicity very challenging.
SN - 2090-6749
SN - 2090-6757
ER -