Lightweight convolutional neural networks for detecting middle cerebral artery stenosis on TCD spectral images: discriminative performance, probability calibration and deployment value
- 1Central Hospital Affiliated to Shenyang Medical College
Abstract
Background: Transcranial Doppler (TCD) is a portable bedside tool for screening middle cerebral artery (MCA) stenosis, but its accuracy depends strongly on operator experience. Most reported deep-learning studies optimize one architecture and assess discrimination only, leaving open the architecture’s point-of-care cost and whether its output probability can be trusted.
Methods: In this retrospective single-center study, 1,835 TCD spectral images (1,641 development; 194 held-out) were analyzed per vessel-side image. Four backbones spanning a 7.7-fold parameter range—ResNet50, EfficientNet-B0, EfficientNetV2-S, MobileNetV3-Large—shared a head under unified fine-tuning. The candidate was chosen by a rule that fixes discrimination eligibility on development-cohort out-of-fold predictions and then ranks the eligible backbones by measured CPU cost, applied before any held-out-cohort scoring: lowest CPU latency among backbones whose development-cohort AUC was statistically indistinguishable from the best. Protocols used validation-only grid search; the loss was ablated; readiness was assessed via ECE, Brier, Murphy decomposition, Grad-CAM.
Results: All backbones showed statistically indistinguishable held-out discrimination (AUC 0.9995–0.9999; every paired bootstrap ΔAUC 95% CI included zero), while cost differed by an order of magnitude: MobileNetV3-Large used 7.7 × fewer parameters and 19 × fewer FLOPs than ResNet50, ran 1.6–9.5 × faster, and matched it within noise. The rule selected MobileNetV3-Large as primary (EfficientNet-B0 secondary); FLOPs did not predict CPU latency. Validation-only temperature scaling reduced ECE to 0.0102–0.0161; residual Brier was almost entirely reliability.
Conclusion: For TCD-based MCA stenosis detection, discrimination saturated across backbones spanning an order of magnitude in cost; in this single-center dataset, deployment cost therefore provided a pragmatic criterion for architecture selection rather than AUC. This single-center, single-device retrospective study does not establish external generalization; multicenter prospective validation formally remains required before clinical use.
Related
- Lightweight Calibration-Based Blood Pressure Tracking from Photoplethysmography Features for Smart Devices: Accuracy, Model Size and Recalibration Interval
- Lightweight convolutional neural network for UAV onboard visual anomaly detection and localization
- Evaluation of the pSOFA Score in a Pediatric Intensive Care Unit and Its Discriminative Performance Compared with PRISM 4 and PIM 3.
- Triglycerides, Total Cholesterol, and Body Weight Index Demonstrates High Discriminative Performance for Metabolic Syndrome: A Comparative Study with Established Cardiometabolic and Inflammatory Indices
- Discriminative Performance of Anthropometric and Body Composition Measures for Identifying CONUT-Defined Nutritional Risk in Hospitalized Older Adults: A Cross-Sectional Study
BibTeX
@article{zhao2026lightweight,
title = {{Lightweight convolutional neural networks for detecting middle cerebral artery stenosis on TCD spectral images: discriminative performance, probability calibration and deployment value}},
author = {Qian Zhao and Li Sun and Nannan Li and Xiaoping Zhang},
journal = {Frontiers in Neurology},
year = {2026},
month = nov,
doi = {10.3389/fneur.2026.1960825},
url = {https://www.frontiersin.org/articles/10.3389/fneur.2026.1960825/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Lightweight convolutional neural networks for detecting middle cerebral artery stenosis on TCD spectral images: discriminative performance, probability calibration and deployment value
AU - Qian Zhao
AU - Li Sun
AU - Nannan Li
AU - Xiaoping Zhang
PY - 2026
DA - 2026/11/26
JO - Frontiers in Neurology
DO - 10.3389/fneur.2026.1960825
UR - https://www.frontiersin.org/articles/10.3389/fneur.2026.1960825/full
AB - Background: Transcranial Doppler (TCD) is a portable bedside tool for screening middle cerebral artery (MCA) stenosis, but its accuracy depends strongly on operator experience. Most reported deep-learning studies optimize one architecture and assess discrimination only, leaving open the architecture’s point-of-care cost and whether its output probability can be trusted. Methods: In this retrospective single-center study, 1,835 TCD spectral images (1,641 development; 194 held-out) were analyzed per vessel-side image. Four backbones spanning a 7.7-fold parameter range—ResNet50, EfficientNet-B0, EfficientNetV2-S, MobileNetV3-Large—shared a head under unified fine-tuning. The candidate was chosen by a rule that fixes discrimination eligibility on development-cohort out-of-fold predictions and then ranks the eligible backbones by measured CPU cost, applied before any held-out-cohort scoring: lowest CPU latency among backbones whose development-cohort AUC was statistically indistinguishable from the best. Protocols used validation-only grid search; the loss was ablated; readiness was assessed via ECE, Brier, Murphy decomposition, Grad-CAM. Results: All backbones showed statistically indistinguishable held-out discrimination (AUC 0.9995–0.9999; every paired bootstrap ΔAUC 95% CI included zero), while cost differed by an order of magnitude: MobileNetV3-Large used 7.7 × fewer parameters and 19 × fewer FLOPs than ResNet50, ran 1.6–9.5 × faster, and matched it within noise. The rule selected MobileNetV3-Large as primary (EfficientNet-B0 secondary); FLOPs did not predict CPU latency. Validation-only temperature scaling reduced ECE to 0.0102–0.0161; residual Brier was almost entirely reliability. Conclusion: For TCD-based MCA stenosis detection, discrimination saturated across backbones spanning an order of magnitude in cost; in this single-center dataset, deployment cost therefore provided a pragmatic criterion for architecture selection rather than AUC. This single-center, single-device retrospective study does not establish external generalization; multicenter prospective validation formally remains required before clinical use.
SN - 1664-2295
ER -