A Robotic Tele-Laser System for Remote Visualization and Nd:YAG Laser Triggering: A Preclinical Feasibility Study

4 affiliations
  1. 1Zhongshan Ophthalmic Center, Sun Yat-sen University, WHO Collaborating Centre for Eye Care and Vision, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
  2. 2School of Medicine and Health, Technical University of Munich, Munich, Germany
  3. 3Hainan Eye Hospital and Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Haikou, China
  4. 4Department of Genetics and Biomedical Informatics, Zhongshan School of Medicine, Institute for Frontier Interdisciplinary Research in Health Sciences and Technology, Sun Yat-sen University, Guangzhou, China

Abstract

Purpose: To evaluate the technical feasibility and short-term procedural safety of a remotely operated robotic tele-laser platform for anterior-segment neodymium-doped yttrium aluminum garnet (Nd:YAG) laser delivery in rabbit models.

Methods: A remotely operated, robotic tele-laser platform integrating a customizable finger robot, stereoscopic visualization, and a Nd:YAG laser device was developed to enable ophthalmologists to remotely perform laser treatments. Twenty-four rabbits were allocated into two predefined experimental cohorts: a posterior capsular opacification (PCO) cohort (n = 12) and a laser peripheral iridotomy (LPI) cohort (n = 12). Within each cohort, animals were assigned into remotely operated and on-site subgroups. Outcome measures included technical completion, laser-delivery duration, laser parameters, engineering performance, and postoperative findings.

Results: All 24 procedures were technically completed. For capsulotomy, median laser-delivery duration was 285.0 seconds (interquartile range [IQR], 161.5–793.5) in the remotely operated group and 214.0 seconds (IQR, 173.25–441.0) in the on-site group (P = 0.589). Intraocular lens (IOL) pitting within the central 3-mm optical zone occurred in four of six eyes and in three of six eyes, respectively. For LPI, no statistically significant between-group differences were detected in laser-delivery duration, laser parameters, or change from baseline at postoperative day 1 in intraocular pressure (IOP). Mean targeting errors were 0.0380 ± 0.0174 mm in the remotely operated procedure and 0.0341 ± 0.0230 mm on site (P = 0.053). Mean glass-to-glass video latency and button-to-laser activation latency were 258.6 ± 10.2 ms and 522.7 ± 29.3 ms, respectively.

Conclusions: This controlled preclinical study demonstrates the feasibility of a remotely operated robotic tele-laser platform for anterior-segment laser delivery. The platform enabled remote completion of capsulotomy and LPI workflows under controlled experimental conditions and provides a foundation for further engineering and translational validation.

Translational Relevance: This study demonstrates the preliminary feasibility of a remotely operated robotic tele-laser platform in a preclinical animal model. This platform enables remote expert participation in laser treatment workflows and provides a foundation for future tele-laser applications. Further engineering optimization, safety validation, and clinical studies are required before translation into human ophthalmic practice.

Related

  1. Single-port robotic totally extraperitoneal inguinal hernia repair using a floating docking technique with the da Vinci SP system: feasibility across a spectrum of hernia complexity
    Junhyung Park, Seong-Taek Oh, Jaeim Lee
    Journal of Abdominal Wall SurgeryPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  2. Intraoperative recall of surgeon-defined 3-dimensional planning during robotic pulmonary resection: A feasibility study
    Naoya Kawakita, Tomohiro Toko, Shiori Matsui +8
    JTCVS techniquesPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Feasibility of the Pleural Sliding Test for Detection and Management of Lung Adhesions During Robotic Cardiac Surgery
    Murat Bastopcu, Gökhan Arslanhan, Zeynep Sıla Özcan +5
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Bibliometric analysis and visualization of antidepressant-gut microbiota research : From preclinical exploration to clinical translation (2000–2026)
    Siliang Zeng, Wen Zheng, Dongfeng Wan +1
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  5. Feasibility of a Deep-Learning Model for Objective Visualization-Quality Assessment During Cholangioscopy-Guided Lithotripsy: A Proof-of-Concept Study.
    Hideki Kamada, Kiyoyuki Kobayashi, Hiroki Yamana +7
    DEN openPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{xu2026robotic,
  title = {{A Robotic Tele-Laser System for Remote Visualization and Nd:YAG Laser Triggering: A Preclinical Feasibility Study}},
  author = {Andi Xu and Yining Huang and Zhangkai Lian and Naiji Yu and Ruiyang Li and Yangfan Yang and Qiong Ke and Mohammad Ali Nasseri and Qianni Wu and Wenben Chen and Haotian Lin},
  journal = {Translational Vision Science \& Technology},
  year = {2026},
  month = oct,
  doi = {10.1167/tvst.15.10.40},
  url = {https://doi.org/10.1167/tvst.15.10.40},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - A Robotic Tele-Laser System for Remote Visualization and Nd:YAG Laser Triggering: A Preclinical Feasibility Study
AU  - Andi Xu
AU  - Yining Huang
AU  - Zhangkai Lian
AU  - Naiji Yu
AU  - Ruiyang Li
AU  - Yangfan Yang
AU  - Qiong Ke
AU  - Mohammad Ali Nasseri
AU  - Qianni Wu
AU  - Wenben Chen
AU  - Haotian Lin
PY  - 2026
DA  - 2026/10/26
JO  - Translational Vision Science & Technology
DO  - 10.1167/tvst.15.10.40
UR  - https://doi.org/10.1167/tvst.15.10.40
AB  - Purpose: To evaluate the technical feasibility and short-term procedural safety of a remotely operated robotic tele-laser platform for anterior-segment neodymium-doped yttrium aluminum garnet (Nd:YAG) laser delivery in rabbit models.  Methods: A remotely operated, robotic tele-laser platform integrating a customizable finger robot, stereoscopic visualization, and a Nd:YAG laser device was developed to enable ophthalmologists to remotely perform laser treatments. Twenty-four rabbits were allocated into two predefined experimental cohorts: a posterior capsular opacification (PCO) cohort (n = 12) and a laser peripheral iridotomy (LPI) cohort (n = 12). Within each cohort, animals were assigned into remotely operated and on-site subgroups. Outcome measures included technical completion, laser-delivery duration, laser parameters, engineering performance, and postoperative findings.  Results: All 24 procedures were technically completed. For capsulotomy, median laser-delivery duration was 285.0 seconds (interquartile range [IQR], 161.5–793.5) in the remotely operated group and 214.0 seconds (IQR, 173.25–441.0) in the on-site group (P = 0.589). Intraocular lens (IOL) pitting within the central 3-mm optical zone occurred in four of six eyes and in three of six eyes, respectively. For LPI, no statistically significant between-group differences were detected in laser-delivery duration, laser parameters, or change from baseline at postoperative day 1 in intraocular pressure (IOP). Mean targeting errors were 0.0380 ± 0.0174 mm in the remotely operated procedure and 0.0341 ± 0.0230 mm on site (P = 0.053). Mean glass-to-glass video latency and button-to-laser activation latency were 258.6 ± 10.2 ms and 522.7 ± 29.3 ms, respectively.  Conclusions: This controlled preclinical study demonstrates the feasibility of a remotely operated robotic tele-laser platform for anterior-segment laser delivery. The platform enabled remote completion of capsulotomy and LPI workflows under controlled experimental conditions and provides a foundation for further engineering and translational validation.  Translational Relevance: This study demonstrates the preliminary feasibility of a remotely operated robotic tele-laser platform in a preclinical animal model. This platform enables remote expert participation in laser treatment workflows and provides a foundation for future tele-laser applications. Further engineering optimization, safety validation, and clinical studies are required before translation into human ophthalmic practice.
SN  - 2164-2591
ER  -