Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated just now
Peer-reviewedCC BY 4.0Photoacoustics

Longitudinal evaluation of glucose detection accuracy by spectroscopic mid-infrared optoacoustic sensing in phantoms

  1. 1Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine and Health & School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
  2. 2Institute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany
  3. 3Munich Institute of Robotics and Machine Intelligence (MIRMI), Technical University of Munich, Munich, Germany

Abstract

Mid‑infrared Optoacoustic Spectroscopy (MiROS) has recently shown strong correlation with blood glucose in-vivo in mice, but MiROS’ long‑term performance following calibration and robustness to unseen background compositions remain unclear. We examined MiROS signal variation in relation to glucose concentrations in phantoms over periods exceeding one week, and assessed the effect of varying background constituents on glucose readings. With daily calibration, aqueous phantoms showed reproducible signals over 12 days, achieving a mean absolute error (MAE) of 9–12 mg/dL. Calibration using data from multiple prior days resulted in comparable accuracy (MAE: 12–13 mg/dL), indicating no deterioration despite increasing temporal separation between calibration and measurement. Additionally, MiROS remained robust to chemically diverse and previously unseen spectral backgrounds designed to emulate tissue variability, yielding glucose prediction errors of approximately 20 mg/dL. Collectively, these findings demonstrate the temporal stability and robustness of MiROS, supporting its further development as a platform for non-invasive glucose sensing.

Related

  1. Complementary Molecular and Spectroscopic Approaches for Meat Authentication: Real-Time PCR Detection of Porcine DNA and FT-NIR Analysis of Slaughter-Related Biochemical Changes
    Diyas Myrzakozha, Elmira Karlova, Saule Meldebekova +4
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationCrossrefEurope PMC
  2. Spectroscopic evaluation of the interaction of myoglobin with biomedically relevant compounds
    Alexandra Mânzat, Nicoleta Andrian, Cezara Zăgrean-Tuza +2
    Journal of Biological Inorganic ChemistryPeer-reviewedCC BY 4.0Full textGeneral biochemistryPMC
  3. Long-read sequencing enables high-accuracy mitochondrial heteroplasmy detection in Parkinson's disease.
    Theresa Lüth, Susen Schaake, Christoph Much +7
    BMC genomicsPeer-reviewedCC BYFull textMolecular biology & gene regulationEurope PMCCrossref
  4. Development and initial evaluation of a urine DNA methylation assay for pan-urinary cancer detection
    Haohao Li, Junyao Guo, Bo Hong +4
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textMolecular biology & gene regulationCrossref
  5. Analytical and Clinical Evaluation of the MeltArray Glioma Assay for Rapid Multiplex Detection of 18 Hotspot Mutations in FFPE Gliomas
    Boheng Xu, Wuhao Lin, Wei Ni +5
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0Full textGeneral biochemistryCrossrefEurope PMC
BibTeX
@article{prebeck2026longitudinal,
  title = {{Longitudinal evaluation of glucose detection accuracy by spectroscopic mid-infrared optoacoustic sensing in phantoms}},
  author = {Alexander Prebeck and Aikaterini Mavroudi and Uli Stahl and Vasilis Ntziachristos},
  journal = {Photoacoustics},
  year = {2026},
  month = oct,
  doi = {10.1016/j.pacs.2026.100901},
  url = {https://doi.org/10.1016/j.pacs.2026.100901},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Longitudinal evaluation of glucose detection accuracy by spectroscopic mid-infrared optoacoustic sensing in phantoms
AU  - Alexander Prebeck
AU  - Aikaterini Mavroudi
AU  - Uli Stahl
AU  - Vasilis Ntziachristos
PY  - 2026
DA  - 2026/10/30
JO  - Photoacoustics
DO  - 10.1016/j.pacs.2026.100901
UR  - https://doi.org/10.1016/j.pacs.2026.100901
AB  - Mid‑infrared Optoacoustic Spectroscopy (MiROS) has recently shown strong correlation with blood glucose in-vivo in mice, but MiROS’ long‑term performance following calibration and robustness to unseen background compositions remain unclear. We examined MiROS signal variation in relation to glucose concentrations in phantoms over periods exceeding one week, and assessed the effect of varying background constituents on glucose readings. With daily calibration, aqueous phantoms showed reproducible signals over 12 days, achieving a mean absolute error (MAE) of 9–12 mg/dL. Calibration using data from multiple prior days resulted in comparable accuracy (MAE: 12–13 mg/dL), indicating no deterioration despite increasing temporal separation between calibration and measurement. Additionally, MiROS remained robust to chemically diverse and previously unseen spectral backgrounds designed to emulate tissue variability, yielding glucose prediction errors of approximately 20 mg/dL. Collectively, these findings demonstrate the temporal stability and robustness of MiROS, supporting its further development as a platform for non-invasive glucose sensing.
SN  - 2213-5979
ER  -