Biomechanical evaluation of multi-bevel angled flexible needle insertion to improve deflection and decrease insertion force

  1. 1Key Laboratory of Advanced Manufacturing and Intelligent Technology, Harbin University of Science and Technology
  2. 2College of Information Engineering, Yangzhou University

Abstract

Beveled-tip flexible needles facilitate steering during minimally invasive procedures by producing a transverse force that induces deflection, enabling steering around critical anatomical organs. An optimal bevel tip configuration of a flexible needle efficiently divides the insertion force into axial and transverse components, enhancing steerability while simultaneously reducing tissue penetration resistance. A dual-bevel needle design featuring a 30° primary bevel and a 15° secondary bevel offers the advantage of high deflection with low insertion force and a minimal penetration force. Excessively high penetration force can lead to buckling, while a very low penetration force risks harming vital organs unnoticed. This new type of multi-bevel-angle needle has moderate penetration force with less insertion force and provides greater deflection. A comprehensive modeling approach combines Mooney-Rivlin hyperelastic material properties (to represent tissue behavior) with Euler-Bernoulli beam theory (to predict needle deflection). Experimental validation was conducted using agar-based tissue phantoms characterized by C10 = 46.72 kPa, C01 = − 35.12 kPa, and a Young’s modulus of 69.6 kPa. Results demonstrate that the (30 + 15)° dual-bevel needle achieved a deflection of 16.00 mm at an insertion depth of 130 mm, exceeding the performance of the single-bevel 15-degree needle (14.31 mm) and the single-bevel 30-degree needle (13.38 mm) by 12% and 19.5%, respectively, while maintaining a low insertion force of 2.34 N. The proposed analytical model demonstrates strong agreement with experimental data, achieving correlation coefficients above 0.95 for depths greater than 65 mm. A polynomial trajectory fitting accurately reconstructs full needle paths with an R2 value near 1.0 and RMSE below 0.15 mm. The multi-bevel-angle strategy with a computational platform improves the targeting accuracy for clinical applications.

Related

  1. Intraoperative evaluation of spinal cord tension by shear wave elastography (SWE): a biomechanical study on an ovine model
    Tiguida Kadiaké, Sylvain Persohn, Pierre Yves Rohan +4
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyHAL
  2. Biomechanical evaluation of the gravity varus test in a cadaveric model of posterolateral rotatory instability of the elbow.
    Jordan A Bauer, Rohan Rajan, Rajendra Singh +6
    JSES internationalPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. Oromucosal administration of oxytocin and its receptor antagonist atosiban respectively increase and decrease preferential attention to dynamic social stimuli in men
    Y. Zhang, X. Wang, Y. Wang +2
    medRxivPreprintAll rights reservedFull textPharmacology & toxicologymedRxiv
  4. Partial attenuated PTH suppression of calcimimetics may be due to the resulting hypocalcemia or a significant decrease in serum calcium levels within the normal reference range without adequate calcium supplementation
    De-ru Kong, De-ya Kong, Li-yuan Mu +3
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. An automated long-term bridge deflection monitoring system based on subpixel laser spot localization
    Haoran Wang, Lianxin Zhang, Xiugang Zhang
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{muzzammil2026biomechanical,
  title = {{Biomechanical evaluation of multi-bevel angled flexible needle insertion to improve deflection and decrease insertion force}},
  author = {H. M. Muzzammil and Yongde Zhang and Suoliang Niu and Bing Li and Qihang Yuan},
  journal = {Scientific Reports},
  year = {2026},
  month = jul,
  doi = {10.1038/s41598-026-62181-3},
  url = {https://doi.org/10.1038/s41598-026-62181-3},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Biomechanical evaluation of multi-bevel angled flexible needle insertion to improve deflection and decrease insertion force
AU  - H. M. Muzzammil
AU  - Yongde Zhang
AU  - Suoliang Niu
AU  - Bing Li
AU  - Qihang Yuan
PY  - 2026
DA  - 2026/07/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-62181-3
UR  - https://doi.org/10.1038/s41598-026-62181-3
AB  - Beveled-tip flexible needles facilitate steering during minimally invasive procedures by producing a transverse force that induces deflection, enabling steering around critical anatomical organs. An optimal bevel tip configuration of a flexible needle efficiently divides the insertion force into axial and transverse components, enhancing steerability while simultaneously reducing tissue penetration resistance. A dual-bevel needle design featuring a 30° primary bevel and a 15° secondary bevel offers the advantage of high deflection with low insertion force and a minimal penetration force. Excessively high penetration force can lead to buckling, while a very low penetration force risks harming vital organs unnoticed. This new type of multi-bevel-angle needle has moderate penetration force with less insertion force and provides greater deflection. A comprehensive modeling approach combines Mooney-Rivlin hyperelastic material properties (to represent tissue behavior) with Euler-Bernoulli beam theory (to predict needle deflection). Experimental validation was conducted using agar-based tissue phantoms characterized by C10 = 46.72 kPa, C01 = − 35.12 kPa, and a Young’s modulus of 69.6 kPa. Results demonstrate that the (30 + 15)° dual-bevel needle achieved a deflection of 16.00 mm at an insertion depth of 130 mm, exceeding the performance of the single-bevel 15-degree needle (14.31 mm) and the single-bevel 30-degree needle (13.38 mm) by 12% and 19.5%, respectively, while maintaining a low insertion force of 2.34 N. The proposed analytical model demonstrates strong agreement with experimental data, achieving correlation coefficients above 0.95 for depths greater than 65 mm. A polynomial trajectory fitting accurately reconstructs full needle paths with an R2 value near 1.0 and RMSE below 0.15 mm. The multi-bevel-angle strategy with a computational platform improves the targeting accuracy for clinical applications.
SN  - 2045-2322
ER  -