Skip to content
DraconiticResearch
Search Sources API
203,952 studies31 sourcesUpdated 38 min ago
Peer-reviewedCC BY 4.0Scientific Reports

Vibration identification and reduction of a reciprocating compressor suction bottle with long cantilever structure

Abstract

Excessive vibration in reciprocating compressor systems can threaten equipment reliability, operational safety, and production continuity. In this study, the root cause and reduction of excessive vibration in a compressor suction system were investigated through vibration testing, modal analysis, transient flow-field analysis, and buckling analysis. Vibration measurements and modal analysis demonstrated that the excessive vibration was not caused by mechanical resonance. Transient flow-field analysis revealed that the intermittent suction process generated significant fluid-induced excitation forces, with the dominant excitation force reaching 63–68 kN in the vertical direction. Buckling analysis showed a minimum critical buckling load of only 6.463 MPa in the horizontal direction, indicating that the long cantilever configuration of the suction bottle provided insufficient structural stiffness and stability. To mitigate vibration, a vibration reduction scheme was proposed that involved shortening the cantilever sections and relocating the inlet nozzle to the axial center of the suction bottle. These structural modifications increased the mechanical natural frequencies and enlarged the frequency separation margin from the compressor excitation frequencies. Moreover, the dominant fluid-induced excitation force in the vertical direction decreased from 63–68 to 51.6–55.1 kN, and the minimum critical buckling load in the horizontal direction increased by 52.57%, from 6.463 to 9.861 MPa. Field implementation verified the effectiveness of the proposed scheme, with vibration velocities reduced by more than 40% and all measured velocities decreasing to below the ISO 20816–1 limit of 18 mm/s. The proposed methodology provides a practical solution for vibration diagnosis, structural optimization, and vibration mitigation in reciprocating compressor systems.

Related

  1. Vibration-Based Numerical and Experimental Analysis on Delamination Damage Identification for Composite Laminates
    Shuxia Tian, Guangke Li, Shuai Liu
    Materials (Basel, Switzerland)Peer-reviewedCC BYFull textEurope PMC
  2. A hybrid ANN-metaheuristic framework for vibration-based identification of orthotropic parameters in GFRP laminated plates
    Solomon Alemneh Adimass, Arkadiusz Żak, Łukasz Doliński
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCrossref
  3. Identification of Lithology Based on Vibration Response of Drill Bit
    Chong Wang, Qilong Xue, Zhengzhou Peng +3
    Sensors (Basel, Switzerland)Peer-reviewedCC BYFull textEurope PMC
  4. Matched-Compliance Benchmarking of Perforated and Uniformly Thinned Substrates for Piezoelectric Cantilever Energy Harvesters
    Saad F. Almokmesh, Bashar B. Alzuwayer
    MicromachinesPeer-reviewedCC BYFull textEurope PMC
  5. A novel microscale multilayer PZT MEMS cantilever for resonant photoacoustic gas sensing
    Shan Lin, Yongkang Gong, Aron Michael +3
    PhotoacousticsPeer-reviewedCC BYFull textEurope PMC
BibTeX
@article{li2026vibration,
  title = {{Vibration identification and reduction of a reciprocating compressor suction bottle with long cantilever structure}},
  author = {Shuangshuang Li and Xiao Yin and Guofu Yin and Jun Chen and Liwen Zhang},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-70369-w},
  url = {https://www.nature.com/articles/s41598-026-70369-w},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Vibration identification and reduction of a reciprocating compressor suction bottle with long cantilever structure
AU  - Shuangshuang Li
AU  - Xiao Yin
AU  - Guofu Yin
AU  - Jun Chen
AU  - Liwen Zhang
PY  - 2026
DA  - 2026/10/04
JO  - Scientific Reports
DO  - 10.1038/s41598-026-70369-w
UR  - https://www.nature.com/articles/s41598-026-70369-w
AB  - Excessive vibration in reciprocating compressor systems can threaten equipment reliability, operational safety, and production continuity. In this study, the root cause and reduction of excessive vibration in a compressor suction system were investigated through vibration testing, modal analysis, transient flow-field analysis, and buckling analysis. Vibration measurements and modal analysis demonstrated that the excessive vibration was not caused by mechanical resonance. Transient flow-field analysis revealed that the intermittent suction process generated significant fluid-induced excitation forces, with the dominant excitation force reaching 63–68 kN in the vertical direction. Buckling analysis showed a minimum critical buckling load of only 6.463 MPa in the horizontal direction, indicating that the long cantilever configuration of the suction bottle provided insufficient structural stiffness and stability. To mitigate vibration, a vibration reduction scheme was proposed that involved shortening the cantilever sections and relocating the inlet nozzle to the axial center of the suction bottle. These structural modifications increased the mechanical natural frequencies and enlarged the frequency separation margin from the compressor excitation frequencies. Moreover, the dominant fluid-induced excitation force in the vertical direction decreased from 63–68 to 51.6–55.1 kN, and the minimum critical buckling load in the horizontal direction increased by 52.57%, from 6.463 to 9.861 MPa. Field implementation verified the effectiveness of the proposed scheme, with vibration velocities reduced by more than 40% and all measured velocities decreasing to below the ISO 20816–1 limit of 18 mm/s. The proposed methodology provides a practical solution for vibration diagnosis, structural optimization, and vibration mitigation in reciprocating compressor systems.
SN  - 2045-2322
ER  -