Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 19 min ago
Peer-reviewedCC BYBiosensors

Discriminating Between Hydroxycinnamic and Hydroxybenzoic Acids with an Electrochemical Laccase-Based Biosensor.

4 affiliations
  1. 1Centre of Technologies, Plovdiv University 'Paisii Hilendarski', 21 Kostaki Peev Str., 4000 Plovdiv, Bulgaria.
  2. 2Department of Organic Chemistry and Inorganic Chemistry, University of Food Technologies, 26 Maritsa Blvd., 4002 Plovdiv, Bulgaria.
  3. 3Department of Biochemistry and Microbiology, Plovdiv University 'Paisii Hilendarski', 24 Tzar Assen Str., 4000 Plovdiv, Bulgaria.
  4. 4Department of Physical Chemistry, Plovdiv University 'Paisii Hilendarski', 24 Tzar Assen Str., 4000 Plovdiv, Bulgaria.

Abstract

Laccase enzyme is recognised for its ability to selectively oxidise o- or p-diphenolic compounds in the presence of molecular oxygen. Because some of these compounds are natural antioxidants with limited water solubility, this study presents an optimised laccase-based electrochemical biosensor operating in a mixed medium (ethanol-aqueous buffer). The catalytic action of the enzyme on syringic, caffeic, chlorogenic, ferulic, and p-coumaric acids was examined by cyclic voltammetry, revealing that the first three phenolic acids effectively mediated electron transport between the laccase active site and the electrode surface, while the interaction between the enzyme and either ferulic or p-coumaric acids was not electrochemically detectable. Furthermore, the sensitivity, linear dynamic range, and limits of detection and quantification for the first three acids were determined by amperometry at a constant potential. Both hydroxycinnamic acids-caffeic and chlorogenic-can be sensed at an applied potential of 0.2 V (vs. Ag|AgCl) or lower, while syringic acid (a hydroxybenzoic acid) is detectable at -0.3 V or lower. Building on these studies, a methodology was developed and applied to discriminate between hydroxycinnamic and hydroxybenzoic acids and quantify them in alcoholic extracts of coffee and wild cranberries. The biosensing results were compared with those obtained by chromatography, with the analytical results matching from 81% to 95% the ones obtained by HPLC.

Related

  1. Electrochemical detection of hepatitis B virus DNA: a biosensor based on MnO2/MWCNT/AgNPs composite material
    Yuzhen Zhu, Ying Huang, Nicole Jaffrezic-Renault +2
    PolyhedronPeer-reviewedLicence not statedGeneral chemistryHAL
  2. An electrochemical biosensor based on antifouling conductive hydrogel for umami detection in complex fish matrices
    Mengjie Qin, Yuanyuan Luo, Feng Hong +6
    Food Chemistry: XPeer-reviewedCC BY-NC-ND 4.0Full textAnalytical chemistryPMC
  3. Cardiolipin-Based Electrochemical Biosensor for Non-treponemal Antibody Detection Using Screen-Printed Electrodes: A Proof-of-Concept Study
    Duane da Silva Moraes, Bruna Ferri Serafini, Felipe Longaray Kadel +5
    ACS OmegaPeer-reviewedCC BY 4.0Full textGeneral chemistryCrossrefPMC
  4. Tyrosinase–SWCNT Electrochemical Biosensor for Tyramine Detection: Experimental Development and Molecular Dynamics Insights
    Nurul Hana Mas’od, Mohammad Nazri Abdul Bahari, Syaza Azhari +3
    ACS OmegaPeer-reviewedCC BY-NC-ND 4.0Full textGeneral chemistryCrossrefEurope PMCEurope PMCPMC
  5. Wearable Organic Electrochemical Transistor Biosensor for Real-Time Measurement of Sweat Salinity and Saturation
    Francesco Gentile, Edmondo Battista, Daniela Cardone +8
    ACS OmegaPeer-reviewedCC BY-NC-ND 4.0Full textGeneral chemistryCrossrefPMC
BibTeX
@article{dodevska2026discriminating,
  title = {{Discriminating Between Hydroxycinnamic and Hydroxybenzoic Acids with an Electrochemical Laccase-Based Biosensor.}},
  author = {Totka Dodevska and Petar Slavov and Mariana Nikolova and Ilia Iliev and Nina Dimcheva},
  journal = {Biosensors},
  year = {2026},
  month = nov,
  doi = {10.3390/bios16110666},
  url = {https://europepmc.org/article/MED/43082561},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Discriminating Between Hydroxycinnamic and Hydroxybenzoic Acids with an Electrochemical Laccase-Based Biosensor.
AU  - Totka Dodevska
AU  - Petar Slavov
AU  - Mariana Nikolova
AU  - Ilia Iliev
AU  - Nina Dimcheva
PY  - 2026
DA  - 2026/11/19
JO  - Biosensors
DO  - 10.3390/bios16110666
UR  - https://europepmc.org/article/MED/43082561
AB  - Laccase enzyme is recognised for its ability to selectively oxidise o- or p-diphenolic compounds in the presence of molecular oxygen. Because some of these compounds are natural antioxidants with limited water solubility, this study presents an optimised laccase-based electrochemical biosensor operating in a mixed medium (ethanol-aqueous buffer). The catalytic action of the enzyme on syringic, caffeic, chlorogenic, ferulic, and p-coumaric acids was examined by cyclic voltammetry, revealing that the first three phenolic acids effectively mediated electron transport between the laccase active site and the electrode surface, while the interaction between the enzyme and either ferulic or p-coumaric acids was not electrochemically detectable. Furthermore, the sensitivity, linear dynamic range, and limits of detection and quantification for the first three acids were determined by amperometry at a constant potential. Both hydroxycinnamic acids-caffeic and chlorogenic-can be sensed at an applied potential of 0.2 V (vs. Ag|AgCl) or lower, while syringic acid (a hydroxybenzoic acid) is detectable at -0.3 V or lower. Building on these studies, a methodology was developed and applied to discriminate between hydroxycinnamic and hydroxybenzoic acids and quantify them in alcoholic extracts of coffee and wild cranberries. The biosensing results were compared with those obtained by chromatography, with the analytical results matching from 81% to 95% the ones obtained by HPLC.
SN  - 2079-6374
ER  -