Competency Assessment for Ultrasound‐Guided Pharmacopuncture in Pain Management: Development and Initial Validity Evidence for an OSCE Checklist
5 affiliations
- 1Department of Medical Education College of Korean Medicine Kyung Hee University Seoul South Korea khu.ac.kr
- 2Department of Korean Medicine College of Korean Medicine Kyung Hee University Seoul South Korea khu.ac.kr
- 3Department of Medical Education Hanyang University College of Medicine Seoul South Korea hanyang.ac.kr
- 4Department of Clinical Korean Medicine Graduate School Kyung Hee University Seoul South Korea khu.ac.kr
- 5Department of Acupuncture and Moxibustion Kyung Hee University College of Korean Medicine Kyung Hee University Medical Center Seoul South Korea khmc.or.kr
Abstract
Operator competence is central to the safety of ultrasound‐guided procedures in pain management. In Korean medicine, ultrasound‐guided pharmacopuncture is increasingly used as an interventional pain procedure; however, to our knowledge, no procedure‐specific competency assessment tool has been developed for this intervention. This study developed a 17‐item Objective Structured Clinical Examination (OSCE) checklist for ultrasound‐guided pharmacopuncture and examined its initial validity and reliability within Messick’s unified framework. In this retrospective single‐center educational study, 113 fourth‐year Korean medicine students completed a structured training module comprising self‐directed prelearning, supervised phantom practice, and OSCE assessment between August and October 2025; 109 students with complete assessment records were analyzed. Each performance was scored in real time by a primary rater using the checklist (maximum 40 points) and a 2‐item Global Rating Scale (GRS; maximum 10 points) and independently rescored from the video by a blinded secondary rater. Item difficulty, discrimination, corrected item‐total correlation, internal consistency, inter‐rater agreement, inter‐rater reliability, and the checklist–GRS relationship were analyzed, and learner satisfaction was assessed using an Input–Process–Output framework. The mean checklist score was 34.71 (standard deviation = 5.19), and 98 students (89.9%) met the provisional 70% threshold. Sixteen of the 17 items were classified as easy, indicating a ceiling effect, and 16 met the corrected item‐total correlation criterion. Discrimination was highest for the items assessing needle tip confirmation and real‐time needle guidance, which were among the least well‐performed. Internal consistency was acceptable (raw Cronbach’s alpha = 0.800), inter‐rater reliability was excellent for the checklist within each rater pair (intraclass correlation coefficient = 0.972 and 0.986), and checklist scores converged strongly with GRS ratings (Spearman’s rho = 0.838, 0.794 between independent raters). The checklist provides initial validity and reliability evidence for formative competency assessment; multi‐institutional validation, formal standard setting, and real‐patient evaluation are required before high‐stakes use.
Related
- A Competency Assessment Tool for Liver Contrast-Enhanced Ultrasound Among Sonography Trainees: Development and Multicenter Validation Study
- A competency-based assessment system for undergraduate oral and maxillofacial surgery internship: development and pilot validation.
- Assessment in competency-based medical education for anesthesiology: validity evidence, equity, and faculty readiness
- The quest for an ideal EEG competency assessment
- Industry 4.0 Technologies in Health Professions Education: A Scoping Review of Curriculum Innovation and Competency Development
BibTeX
@article{lee2026competency,
title = {{Competency Assessment for Ultrasound‐Guided Pharmacopuncture in Pain Management: Development and Initial Validity Evidence for an OSCE Checklist}},
author = {Min-Jung Lee and A-Hyun Sim and Yoonjung Lee and Yohwan Kim and Taegon Kim and Seung-Jin Noh and Haeryoung Jang and Seunghoon Lee},
journal = {Pain Research \& Management},
year = {2026},
month = nov,
doi = {10.1155/prm/1773806},
url = {https://doi.org/10.1155/prm/1773806},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Competency Assessment for Ultrasound‐Guided Pharmacopuncture in Pain Management: Development and Initial Validity Evidence for an OSCE Checklist
AU - Min-Jung Lee
AU - A-Hyun Sim
AU - Yoonjung Lee
AU - Yohwan Kim
AU - Taegon Kim
AU - Seung-Jin Noh
AU - Haeryoung Jang
AU - Seunghoon Lee
PY - 2026
DA - 2026/11/22
JO - Pain Research & Management
DO - 10.1155/prm/1773806
UR - https://doi.org/10.1155/prm/1773806
AB - Operator competence is central to the safety of ultrasound‐guided procedures in pain management. In Korean medicine, ultrasound‐guided pharmacopuncture is increasingly used as an interventional pain procedure; however, to our knowledge, no procedure‐specific competency assessment tool has been developed for this intervention. This study developed a 17‐item Objective Structured Clinical Examination (OSCE) checklist for ultrasound‐guided pharmacopuncture and examined its initial validity and reliability within Messick’s unified framework. In this retrospective single‐center educational study, 113 fourth‐year Korean medicine students completed a structured training module comprising self‐directed prelearning, supervised phantom practice, and OSCE assessment between August and October 2025; 109 students with complete assessment records were analyzed. Each performance was scored in real time by a primary rater using the checklist (maximum 40 points) and a 2‐item Global Rating Scale (GRS; maximum 10 points) and independently rescored from the video by a blinded secondary rater. Item difficulty, discrimination, corrected item‐total correlation, internal consistency, inter‐rater agreement, inter‐rater reliability, and the checklist–GRS relationship were analyzed, and learner satisfaction was assessed using an Input–Process–Output framework. The mean checklist score was 34.71 (standard deviation = 5.19), and 98 students (89.9%) met the provisional 70% threshold. Sixteen of the 17 items were classified as easy, indicating a ceiling effect, and 16 met the corrected item‐total correlation criterion. Discrimination was highest for the items assessing needle tip confirmation and real‐time needle guidance, which were among the least well‐performed. Internal consistency was acceptable (raw Cronbach’s alpha = 0.800), inter‐rater reliability was excellent for the checklist within each rater pair (intraclass correlation coefficient = 0.972 and 0.986), and checklist scores converged strongly with GRS ratings (Spearman’s rho = 0.838, 0.794 between independent raters). The checklist provides initial validity and reliability evidence for formative competency assessment; multi‐institutional validation, formal standard setting, and real‐patient evaluation are required before high‐stakes use.
SN - 1203-6765
SN - 1918-1523
ER -