Abstract

This study presents a detailed one-year comparative economic analysis of diesel generator versus low-cost solar microgrid operation for a typical household in Khartoum, Sudan under conditions of prolonged grid failure. Field data and utility reports indicate that grid outages in Khartoum now extend to 16-18 hours per day following the destruction of the Al-Markhiyat substation and damage to the Merowe Dam power station, with national generation falling from 4,400 MW to 1,100 MW. The analysis compares two scenarios for meeting a critical load of 5 kWh per day. Scenario A: 3 kW diesel generator consuming 0.8 liters per hour at current Khartoum diesel price of $1.2 per liter, operating 12 hours daily. Annual fuel cost $4,204, maintenance $600, total $4,804. Scenario B: Proposed solar microgrid with 2x550W PV, 5 kWh LiFePO4 battery, 3 kW hybrid inverter costing $850 CAPEX with $20 annual maintenance. Using IRENA data on 93% battery cost decline and 87% solar PV cost decline since 2010, and UN data of 4,000+ sunshine hours in Sudan, results show solar achieves 82.3% annual savings, payback in 2.1 months, and ten-year net present value of $39,190 savings. Sensitivity analysis shows diesel remains uneconomical even if fuel price drops 50%. The study concludes that continued diesel reliance imposes severe financial burden on households already spending $200 per month, while solar microgrid offers sustainable resilience pathway aligning with World Bank goals for 30% of population without access.

Related

  1. Design and Techno-Economic Analysis of a Low-Cost Solar Microgrid for Residential Resilience in Khartoum, Sudan Under Conflict Conditions
    Mugtaba Alfaki
    ZenodoPreprintCC BY 4.0Full textZenodo
  2. Techno-economic optimization and hybrid deep learning-based net-load forecasting for intelligent microgrid energy management using HOMER Pro
    Meenakshi Gupta, Arundathy Ajith, O. V. Gnana Swathika
    Scientific ReportsPeer-reviewedCC BY 4.0Full textCrossref
  3. Comparative Analysis of Microgrid Control Techniques using Variance-Based Methods
    Khaled Belhouchet, Abdelhakim Idir, Assam Zorig +3
    Reliability: Theory & ApplicationsPeer-reviewedCC BY-NCFull textGeneral mathematicsDOAJ
  4. Comparative performance analysis of adaptive neuro-fuzzy inference system, fuzzy logic, and neural network-based maximum power point tracking controllers for permanent magnet synchronous generator-based variable-speed wind energy conversion systems
    Girmay Desalegn Hadush, Simon Fkadeamlak Gebremariam, Solomon Teklehaimanot Meresa +1
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCrossref
  5. Data-driven risk assessment framework for railway operation accidents based on an improved Bayesian network
    Rui Yang, Xuewei Li, Guanyi Liu
    PLOS OnePeer-reviewedCC BY 4.0ProbabilityEpidemiology & public healthPLOS
BibTeX
@misc{alfaki2026comparative,
  title = {{Comparative Economic Analysis of Diesel Generator vs Solar Microgrid Operation in Khartoum: Annual Cost Assessment Under Extended Grid Outages}},
  author = {Mugtaba Alfaki},
  howpublished = {Zenodo},
  year = {2026},
  month = oct,
  doi = {10.5281/zenodo.23676099},
  url = {https://zenodo.org/records/23676099},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Comparative Economic Analysis of Diesel Generator vs Solar Microgrid Operation in Khartoum: Annual Cost Assessment Under Extended Grid Outages
AU  - Mugtaba Alfaki
PY  - 2026
DA  - 2026/10/26
PB  - Zenodo
DO  - 10.5281/zenodo.23676099
UR  - https://zenodo.org/records/23676099
AB  - This study presents a detailed one-year comparative economic analysis of diesel generator versus low-cost solar microgrid operation for a typical household in Khartoum, Sudan under conditions of prolonged grid failure. Field data and utility reports indicate that grid outages in Khartoum now extend to 16-18 hours per day following the destruction of the Al-Markhiyat substation and damage to the Merowe Dam power station, with national generation falling from 4,400 MW to 1,100 MW. The analysis compares two scenarios for meeting a critical load of 5 kWh per day. Scenario A: 3 kW diesel generator consuming 0.8 liters per hour at current Khartoum diesel price of $1.2 per liter, operating 12 hours daily. Annual fuel cost $4,204, maintenance $600, total $4,804. Scenario B: Proposed solar microgrid with 2x550W PV, 5 kWh LiFePO4 battery, 3 kW hybrid inverter costing $850 CAPEX with $20 annual maintenance. Using IRENA data on 93% battery cost decline and 87% solar PV cost decline since 2010, and UN data of 4,000+ sunshine hours in Sudan, results show solar achieves 82.3% annual savings, payback in 2.1 months, and ten-year net present value of $39,190 savings. Sensitivity analysis shows diesel remains uneconomical even if fuel price drops 50%. The study concludes that continued diesel reliance imposes severe financial burden on households already spending $200 per month, while solar microgrid offers sustainable resilience pathway aligning with World Bank goals for 30% of population without access.
ER  -