Evaluation of BioFire® FilmArray® and GENECUBE® for Rapid Molecular Diagnosis of Periprosthetic Hip Joint Infection Using Implant Sonication Fluid.
- 1Department of Orthopaedic Surgery, Yokohama City University, Yokohama City, Kanagawa, Japan.
- 2Department of Orthopaedic Surgery, Yokohama City University Medical Center, Yokohama City, Kanagawa, Japan.
Abstract
Periprosthetic joint infection (PJI) is difficult to diagnose because implants can develop biofilms. Fully automated polymerase chain reaction (PCR) systems rapidly identify organisms in PJI, while implant sonication may improve detection of biofilm-forming organisms. This study evaluated the diagnostic performance of automated PCR using sonication fluid from implants removed from patients with suspected hip PJI. Thirty patients undergoing revision total hip arthroplasty for PJI or aseptic loosening were enrolled. PJI was diagnosed according to the 2018 International Consensus Meeting criteria. Synovial fluid culture was performed, and both synovial fluid and implant sonication fluid were tested using the GENECUBE® and BioFire® FilmArray® Joint Infection Panel (JI Panel). Sensitivity and specificity were calculated for each test. Fifteen patients (50.0%) were diagnosed with PJI. Synovial fluid could not be obtained because of a dry tap in one PJI case (3.3%) and two aseptic loosening cases (6.7%). In synovial fluid, sensitivity was 57.1% for bacterial culture and GENECUBE® and 64.3% for the JI Panel; it increased to 85.7% when both fully automated PCR systems were combined. In implant sonication fluid, sensitivity was 46.7% for GENECUBE® and 66.7% for the BioFire® Joint Infection Panel, increasing to 93.3% when both fully automated PCR systems were combined. No false-positive results occurred in any sample, and specificity was 100% for every test method. CLINICAL SIGNIFICANCE STATEMENT: Combining the two fully automated PCR systems improves the diagnostic performance for PJI. Implant sonication fluid may provide an alternative specimen for molecular testing, particularly when synovial fluid cannot be obtained.
Related
- Pilot evaluation of pathogen isolation using targeted amplicon next-generation sequencing on sonication fluid for the diagnosis of periprosthetic joint infections.
- Implant sonication supporting the diagnosis of low-grade periprosthetic joint infection following reverse shoulder arthroplasty: a case report
- From Measured Accuracy to Patient Outcome: Navigation in Total Hip Arthroplasty and Molecular Diagnosis of Periprosthetic Joint Infection: A Narrative Review
- Rapid diagnosis of Listeria monocytogenes meningitis using the FilmArray meningitis/encephalitis panel in a patient with bacteremia: a case report
- Morphology-Guided Diagnosis of Triple-Negative Breast Carcinoma: From Histopathological Evaluation to Molecular Testing
BibTeX
@article{hieda2026evaluation,
title = {{Evaluation of BioFire® FilmArray® and GENECUBE® for Rapid Molecular Diagnosis of Periprosthetic Hip Joint Infection Using Implant Sonication Fluid.}},
author = {Yuta Hieda and Hyonmin Choe and Koki Abe and Masashi Shimoda and Hironori Yamane and Hiroyuki Ike and Hiroto Kono and Ken Kumagai and Naomi Kobayashi and Yutaka Inaba},
journal = {Journal of orthopaedic research : official publication of the Orthopaedic Research Society},
year = {2026},
month = nov,
doi = {10.1002/jor.70323},
url = {https://europepmc.org/article/MED/43083447},
note = {CC BY},
}
RIS
TY - JOUR
TI - Evaluation of BioFire® FilmArray® and GENECUBE® for Rapid Molecular Diagnosis of Periprosthetic Hip Joint Infection Using Implant Sonication Fluid.
AU - Yuta Hieda
AU - Hyonmin Choe
AU - Koki Abe
AU - Masashi Shimoda
AU - Hironori Yamane
AU - Hiroyuki Ike
AU - Hiroto Kono
AU - Ken Kumagai
AU - Naomi Kobayashi
AU - Yutaka Inaba
PY - 2026
DA - 2026/11/26
JO - Journal of orthopaedic research : official publication of the Orthopaedic Research Society
DO - 10.1002/jor.70323
UR - https://europepmc.org/article/MED/43083447
AB - Periprosthetic joint infection (PJI) is difficult to diagnose because implants can develop biofilms. Fully automated polymerase chain reaction (PCR) systems rapidly identify organisms in PJI, while implant sonication may improve detection of biofilm-forming organisms. This study evaluated the diagnostic performance of automated PCR using sonication fluid from implants removed from patients with suspected hip PJI. Thirty patients undergoing revision total hip arthroplasty for PJI or aseptic loosening were enrolled. PJI was diagnosed according to the 2018 International Consensus Meeting criteria. Synovial fluid culture was performed, and both synovial fluid and implant sonication fluid were tested using the GENECUBE® and BioFire® FilmArray® Joint Infection Panel (JI Panel). Sensitivity and specificity were calculated for each test. Fifteen patients (50.0%) were diagnosed with PJI. Synovial fluid could not be obtained because of a dry tap in one PJI case (3.3%) and two aseptic loosening cases (6.7%). In synovial fluid, sensitivity was 57.1% for bacterial culture and GENECUBE® and 64.3% for the JI Panel; it increased to 85.7% when both fully automated PCR systems were combined. In implant sonication fluid, sensitivity was 46.7% for GENECUBE® and 66.7% for the BioFire® Joint Infection Panel, increasing to 93.3% when both fully automated PCR systems were combined. No false-positive results occurred in any sample, and specificity was 100% for every test method. CLINICAL SIGNIFICANCE STATEMENT: Combining the two fully automated PCR systems improves the diagnostic performance for PJI. Implant sonication fluid may provide an alternative specimen for molecular testing, particularly when synovial fluid cannot be obtained.
SN - 0736-0266
SN - 1554-527X
ER -