Pilot evaluation of pathogen isolation using targeted amplicon next-generation sequencing on sonication fluid for the diagnosis of periprosthetic joint infections.

  1. 1Department of Orthopedic and Traumatology, Musculoskeletal Infection Group, Escola Paulista de Medicina (EPM), Universidade Federal de São Paulo - UNIFESP, São Paulo, Brazil.
  2. 2MicroGen DX, Orlando, FL, USA. [email protected].
  3. 3Acibadem University Hospital, Istanbul, Turkey.

Abstract

Background

Periprosthetic joint infection (PJI) remains difficult to diagnose due to the limited sensitivity of conventional culture, which frequently yields false-negative results. Targeted amplicon next-generation sequencing (tNGS) offers a method capable of identifying fastidious organisms, polymicrobial infections, and antimicrobial resistance genes. This pilot proof-of-concept study evaluated the feasibility of applying tNGS to sonicated fluid from orthopedic implants compared with conventional culture.Methods

Six sonicated fluid samples were collected from patients undergoing revision arthroplasty or removal of osteosynthesis devices between August and September 2024. Implants were processed in saline or Ringer's lactate and subjected to a standardized sonication protocol, followed by aerobic and anaerobic culture. Parallel tNGS analysis targeted bacterial 16S rRNA and fungal internal transcribed spacer regions, sequenced on an Illumina MiSeq platform with bioinformatic quality control and contaminant filtering. Microbial identifications and predicted resistance genes were compared descriptively across methods.Results

Patients ranged in age from 23 to 76 years; comorbidities included diabetes, dyslipidemia, and hypertension. Conventional culture identified pathogens in four of six cases but missed fungi, several bacterial species, and resistance markers. In contrast, NGS successfully processed all six sonicated fluid samples, confirming the technical feasibility of the approach while confirming culture-positive organisms such as Staphylococcus aureus and detecting additional clinically relevant bacteria, fungi (Cladosporium, Rhodotorula), and resistance genes (mecA, aph3') that culture failed to identify. Two samples were negative by both methods. Discrepancies were more frequent in samples processed with Ringer's lactate, suggesting interference with sequencing.Conclusions

This pilot study demonstrated the feasibility of applying targeted amplicon next-generation sequencing to sonicated fluid from orthopedic implants and highlighted its potential to complement conventional culture by identifying fastidious organisms, polymicrobial infections, and resistance determinants. These findings highlight its potential to improve diagnostic accuracy and guide personalized antimicrobial therapy in PJI. Although the small sample size and descriptive design limit generalizability, pilot study provides early evidence supporting the feasibility of applying tNGS to sonicated fluid and identifies methodological considerations for future research. Larger prospective trials are warranted to validate these results and establish NGS as an adjunct or alternative to culture in orthopedic infection diagnostics.Trial registration

The study protocol was approved by the local Institutional Review Board (CAAE: 46277421.1.0000.5479; approval number: 4.713.409).

Related

  1. Evaluation of BioFire® FilmArray® and GENECUBE® for Rapid Molecular Diagnosis of Periprosthetic Hip Joint Infection Using Implant Sonication Fluid.
    Yuta Hieda, Hyonmin Choe, Koki Abe +7
    Journal of orthopaedic research : official publication of the Orthopaedic Research SocietyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Comparative evaluation of metagenomic and targeted next-generation sequencing for pathogen detection in bronchoalveolar lavage fluid from patients with lower respiratory tract infections: a retrospective cohort study.
    Rui Zhao, Heya Na, Wei Miao +5
    Frontiers in cellular and infection microbiologyPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  3. Implant sonication supporting the diagnosis of low-grade periprosthetic joint infection following reverse shoulder arthroplasty: a case report
    Gi-Won Seo, Kunil Seo, Yong-Beom Kim
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Metagenomic next-generation sequencing in tuberculous periprosthetic joint infection: pathogen-detection yield and clinical characteristics compared with common bacterial PJI.
    Jiayu Li, Yuntao Liao, Xiaolin Li +7
    Frontiers in cellular and infection microbiologyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. Baseline Lenacapavir Resistance and Capsid Variability in Bulgaria: A Next-Generation Sequencing Study of Newly Diagnosed HIV-1 Infections.
    Ivailo Alexiev, Aleksandra Partsuneva, Reneta Dimitrova +12
    Pathogens (Basel, Switzerland)Peer-reviewedCC BYFull textInfectious diseaseEurope PMC
BibTeX
@article{kurihara2026pilot,
  title = {{Pilot evaluation of pathogen isolation using targeted amplicon next-generation sequencing on sonication fluid for the diagnosis of periprosthetic joint infections.}},
  author = {Mariana Neri Lucas Kurihara and Ingrid Nayara Santos and Mayara Muniz de Andrade Silva and Laura Batista and Carlos Augusto Finelli and Thomas Stravinskas Durigon and Fernando Baldy Dos Reis and Carolina Coelho Cunha and Julia Freitas Orrico and Javad Parvizi and Mauro José Salles},
  journal = {Pilot and feasibility studies},
  year = {2026},
  month = sep,
  doi = {10.1186/s40814-026-01890-y},
  url = {https://europepmc.org/article/MED/43079665},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Pilot evaluation of pathogen isolation using targeted amplicon next-generation sequencing on sonication fluid for the diagnosis of periprosthetic joint infections.
AU  - Mariana Neri Lucas Kurihara
AU  - Ingrid Nayara Santos
AU  - Mayara Muniz de Andrade Silva
AU  - Laura Batista
AU  - Carlos Augusto Finelli
AU  - Thomas Stravinskas Durigon
AU  - Fernando Baldy Dos Reis
AU  - Carolina Coelho Cunha
AU  - Julia Freitas Orrico
AU  - Javad Parvizi
AU  - Mauro José Salles
PY  - 2026
DA  - 2026/09/02
JO  - Pilot and feasibility studies
DO  - 10.1186/s40814-026-01890-y
UR  - https://europepmc.org/article/MED/43079665
AB  - Background  Periprosthetic joint infection (PJI) remains difficult to diagnose due to the limited sensitivity of conventional culture, which frequently yields false-negative results. Targeted amplicon next-generation sequencing (tNGS) offers a method capable of identifying fastidious organisms, polymicrobial infections, and antimicrobial resistance genes. This pilot proof-of-concept study evaluated the feasibility of applying tNGS to sonicated fluid from orthopedic implants compared with conventional culture.Methods  Six sonicated fluid samples were collected from patients undergoing revision arthroplasty or removal of osteosynthesis devices between August and September 2024. Implants were processed in saline or Ringer's lactate and subjected to a standardized sonication protocol, followed by aerobic and anaerobic culture. Parallel tNGS analysis targeted bacterial 16S rRNA and fungal internal transcribed spacer regions, sequenced on an Illumina MiSeq platform with bioinformatic quality control and contaminant filtering. Microbial identifications and predicted resistance genes were compared descriptively across methods.Results  Patients ranged in age from 23 to 76 years; comorbidities included diabetes, dyslipidemia, and hypertension. Conventional culture identified pathogens in four of six cases but missed fungi, several bacterial species, and resistance markers. In contrast, NGS successfully processed all six sonicated fluid samples, confirming the technical feasibility of the approach while confirming culture-positive organisms such as Staphylococcus aureus and detecting additional clinically relevant bacteria, fungi (Cladosporium, Rhodotorula), and resistance genes (mecA, aph3') that culture failed to identify. Two samples were negative by both methods. Discrepancies were more frequent in samples processed with Ringer's lactate, suggesting interference with sequencing.Conclusions  This pilot study demonstrated the feasibility of applying targeted amplicon next-generation sequencing to sonicated fluid from orthopedic implants and highlighted its potential to complement conventional culture by identifying fastidious organisms, polymicrobial infections, and resistance determinants. These findings highlight its potential to improve diagnostic accuracy and guide personalized antimicrobial therapy in PJI. Although the small sample size and descriptive design limit generalizability, pilot study provides early evidence supporting the feasibility of applying tNGS to sonicated fluid and identifies methodological considerations for future research. Larger prospective trials are warranted to validate these results and establish NGS as an adjunct or alternative to culture in orthopedic infection diagnostics.Trial registration  The study protocol was approved by the local Institutional Review Board (CAAE: 46277421.1.0000.5479; approval number: 4.713.409).
SN  - 2055-5784
ER  -