Skip to content
DraconiticResearch
Search Sources API
186,631 studies31 sourcesUpdated 8 min ago
Peer-reviewedCC BYCVIR endovascular

Clinical outcomes and midterm durability of the preloading coil-in-plug technique in various arterial territories.

  1. 1Department of Radiology, Nara Medical University, Kashihara, Japan.
  2. 2Department of Radiology, Nara Medical University, Kashihara, Japan. [email protected].

Abstract

Background

Conventional coil embolization of large or high-flow arteries may require multiple coils and a long embolization segment. The Amplatzer Vascular Plug (AVP) enables controlled deployment and repositioning; however, complete occlusion partly depends on thrombus formation, and residual flow or recanalization may occur. The preloading coil-in-plug (P-CIP) technique combines the positional stability of an AVP with internal coil packing. This study evaluated its technical feasibility, procedural characteristics, safety, and mid-term imaging outcomes across different arterial territories.Methods

This retrospective single-center study evaluated consecutive patients who underwent P-CIP embolization between April 2018 and April 2026. Before insertion, a microcatheter was passed through the nitinol mesh into the internal space of an AVP I outside the patient. The plug and microcatheter were advanced together and deployed at the target site before plug detachment. Coils were then packed within the expanded plug through the preloaded microcatheter. Technical success, AVP-to-vessel diameter ratio, coil use, coil-packing time, procedure-related complications, target-vessel recanalization, and reintervention were evaluated. Imaging follow-up was based on contrast-enhanced computed tomography.Results

The study included 34 patients, of whom 21 were men, with 40 embolized vessels. The target vessels were the celiac artery in 6 procedures, internal iliac artery in 25, superior or inferior gluteal artery in 8, and external iliac artery in 1. Technical success and final angiographic occlusion were achieved in all 40 vessels. The mean AVP-to-vessel diameter ratio was 1.44, corresponding to 44% oversizing. The mean number of coils used per AVP was 3.13, and the mean coil-packing time was 10.7 min. During a mean imaging follow-up of 619 days, no procedure-related complications, target-vessel recanalization, device migration, or reintervention occurred. Ten patients died during follow-up, but none of the deaths was related to embolization.Conclusions

P-CIP embolization was technically feasible across multiple arterial territories and achieved sustained target-vessel occlusion during mid-term imaging follow-up. The technique may be useful when controlled short-segment embolization is required. Comparative studies are needed to determine whether P-CIP provides advantages over conventional coil embolization or AVP placement alone.

Related

  1. Ultrasound-guided hydrodissection combined with radiofrequency for refractory occipital neuralgia: clinical outcomes, durability, and factors associated with repeat intervention
    Xingchen Yao, Junpeng Liu, Baishan Wu +2
    Frontiers in neurologyPeer-reviewedCC BYFull textNeurologyEurope PMC
  2. Durability of a novel mechanical aortic valve closure technique during left ventricular assist device support: A comparative case report.
    Yuji Shiozaki, Yuki Ichihara, Saeko Yoshizawa +2
    JHLT openPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. The 4D Repair Technique for Incidental Durotomy in Spine Surgery: Surgical Technique and Clinical Outcomes in 112 Patients
    Andrea Franchini, Giuseppe Rovere, Felice Barletta +2
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0NeurologyCrossref
  4. Clinical Outcomes and Complications of Bilateral Cosmetic Femoral Lengthening Using the Lengthening over Nail Technique: A Single-Center Retrospective Study
    Yunus Oc, Muharrem Kanar, Esref Gursel +1
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Epidemiology & public healthCrossref
  5. Clinical outcomes of the crown separation–dislocation–re-segmentation technique for high-risk impacted mandibular third molar extraction: a single-center retrospective cohort study
    Jian Guan, Ruotong Dong, Ruotong Dong +6
    Frontiers in Oral HealthPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{nakai2026clinical,
  title = {{Clinical outcomes and midterm durability of the preloading coil-in-plug technique in various arterial territories.}},
  author = {Takahiro Nakai and Shinichi Iwakoshi and Mako Iwata and Hayato Kishida and Keisuke Oshima and Shigeo Ichihashi and Toshihiro Tanaka},
  journal = {CVIR endovascular},
  year = {2026},
  month = oct,
  doi = {10.1186/s42155-026-00790-9},
  url = {https://europepmc.org/article/MED/42961688},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Clinical outcomes and midterm durability of the preloading coil-in-plug technique in various arterial territories.
AU  - Takahiro Nakai
AU  - Shinichi Iwakoshi
AU  - Mako Iwata
AU  - Hayato Kishida
AU  - Keisuke Oshima
AU  - Shigeo Ichihashi
AU  - Toshihiro Tanaka
PY  - 2026
DA  - 2026/10/30
JO  - CVIR endovascular
DO  - 10.1186/s42155-026-00790-9
UR  - https://europepmc.org/article/MED/42961688
AB  - Background  Conventional coil embolization of large or high-flow arteries may require multiple coils and a long embolization segment. The Amplatzer Vascular Plug (AVP) enables controlled deployment and repositioning; however, complete occlusion partly depends on thrombus formation, and residual flow or recanalization may occur. The preloading coil-in-plug (P-CIP) technique combines the positional stability of an AVP with internal coil packing. This study evaluated its technical feasibility, procedural characteristics, safety, and mid-term imaging outcomes across different arterial territories.Methods  This retrospective single-center study evaluated consecutive patients who underwent P-CIP embolization between April 2018 and April 2026. Before insertion, a microcatheter was passed through the nitinol mesh into the internal space of an AVP I outside the patient. The plug and microcatheter were advanced together and deployed at the target site before plug detachment. Coils were then packed within the expanded plug through the preloaded microcatheter. Technical success, AVP-to-vessel diameter ratio, coil use, coil-packing time, procedure-related complications, target-vessel recanalization, and reintervention were evaluated. Imaging follow-up was based on contrast-enhanced computed tomography.Results  The study included 34 patients, of whom 21 were men, with 40 embolized vessels. The target vessels were the celiac artery in 6 procedures, internal iliac artery in 25, superior or inferior gluteal artery in 8, and external iliac artery in 1. Technical success and final angiographic occlusion were achieved in all 40 vessels. The mean AVP-to-vessel diameter ratio was 1.44, corresponding to 44% oversizing. The mean number of coils used per AVP was 3.13, and the mean coil-packing time was 10.7 min. During a mean imaging follow-up of 619 days, no procedure-related complications, target-vessel recanalization, device migration, or reintervention occurred. Ten patients died during follow-up, but none of the deaths was related to embolization.Conclusions  P-CIP embolization was technically feasible across multiple arterial territories and achieved sustained target-vessel occlusion during mid-term imaging follow-up. The technique may be useful when controlled short-segment embolization is required. Comparative studies are needed to determine whether P-CIP provides advantages over conventional coil embolization or AVP placement alone.
SN  - 2520-8934
ER  -