Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 21 min ago
Peer-reviewedCC BYBMC cancer

Diagnostic performance of the ADNEX model compared with ROMA, RMI, and CPH‑I for ovarian cancer detection: a single‑center retrospective study.

  1. 1Tianjin Cancer Hospital Airport Hospital, Tianjin, 300000, China.
  2. 2Tianjin Cancer Hospital Airport Hospital, Tianjin, 300000, China. [email protected].
  3. 3Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300000, China. [email protected].

Abstract

Background

To evaluate the diagnostic performance of ROMA, RMI, CPH-I, and ADNEX models for ovarian cancer (OC).Methods

This single‑center retrospective study included 190 patients with pelvic masses (June 2024-January 2026). Serum CA125 and HE4 were measured, and ultrasonographic features were recorded. Patients were stratified by pathology into benign (n = 71) and malignant (n = 119) groups, giving a malignancy prevalence of 62.6%. Diagnostic accuracy of all models was compared using ROC curve analysis, optimal cut‑offs were determined via Youden's index.Results

Serum CA125, HE4, ROMA, RMI, CPH-I, and ADNEX values were significantly higher in malignant versus benign, EOC versus non-EOC, and postmenopausal versus premenopausal groups (all P < 0.001). The ADNEX model achieved the highest AUC (0.954), with 94.1% sensitivity and 93.0% specificity at a pre‑specified cut‑off of 10%. Pairwise comparisons showed ADNEX significantly outperformed HE4(P < 0.001), CPHI (P = 0.008), ROMA (P = 0.004), and CA125 (P = 0.006).Conclusion

The ADNEX model demonstrates superior diagnostic accuracy in this high‑risk cohort. Integrated assessment combining serum biomarkers with ultrasonography is essential for accurate preoperative evaluation of pelvic masses.

Related

  1. Comparative Diagnostic Performance of Three Commercial Real‐Time PCR Assays for the Detection of Mycobacterium tuberculosis Complex in Bronchial Washing Specimens: A Large Retrospective Study
    Jimyung Kim, Yumi Park
    Journal of clinical laboratory analysisPeer-reviewedCC BY-NCFull textInfectious diseaseEurope PMCPMC
  2. Performance Assessment of an Artificial Intelligence System Used for Case Detection in a Large Community-based Diabetic Retinopathy Screening Program: A Retrospective Diagnostic Accuracy Validation Study.
    Maria Kristina Dg Eduardo, Junn R Pajarillo
    Acta medica PhilippinaPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMCPMC
  3. Diagnostic Performance of 68Ga-PSMA-11 PET/CT Compared with Multiparametric MRI for Initial Local Staging of Prostate Cancer
    Seong Hyeon Yu, Sang-Geon Cho, Hui Mo Gu +9
    CancersPeer-reviewedCC BY 4.0Full textOncologyCrossrefEurope PMC
  4. Performance of the NightWatch seizure detection device on the leg compared to the standard arm placement: A pilot study
    Megan Krom, Eefke M. Lemmen, Silvia M.A.A. Evers +4
    Epilepsy & Behavior ReportsPeer-reviewedCC BY 4.0Full textNeurologyPMC
  5. Diagnostic Performance of Radiofrequency Echographic Multi Spectrometry Compared with Dual-Energy X-Ray Absorptiometry: A Real-World Study
    Isabella Nardone, Sium Wolde Sellasie, Simona Zaccaria +5
    DiagnosticsPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
BibTeX
@article{feng2026diagnostic,
  title = {{Diagnostic performance of the ADNEX model compared with ROMA, RMI, and CPH‑I for ovarian cancer detection: a single‑center retrospective study.}},
  author = {Yaru Feng and Zhuo Zhang and Aiguo Zhu and Jian Wang},
  journal = {BMC cancer},
  year = {2026},
  month = aug,
  doi = {10.1186/s12885-026-16772-y},
  url = {https://europepmc.org/article/MED/43079345},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Diagnostic performance of the ADNEX model compared with ROMA, RMI, and CPH‑I for ovarian cancer detection: a single‑center retrospective study.
AU  - Yaru Feng
AU  - Zhuo Zhang
AU  - Aiguo Zhu
AU  - Jian Wang
PY  - 2026
DA  - 2026/08/19
JO  - BMC cancer
DO  - 10.1186/s12885-026-16772-y
UR  - https://europepmc.org/article/MED/43079345
AB  - Background  To evaluate the diagnostic performance of ROMA, RMI, CPH-I, and ADNEX models for ovarian cancer (OC).Methods  This single‑center retrospective study included 190 patients with pelvic masses (June 2024-January 2026). Serum CA125 and HE4 were measured, and ultrasonographic features were recorded. Patients were stratified by pathology into benign (n = 71) and malignant (n = 119) groups, giving a malignancy prevalence of 62.6%. Diagnostic accuracy of all models was compared using ROC curve analysis, optimal cut‑offs were determined via Youden's index.Results  Serum CA125, HE4, ROMA, RMI, CPH-I, and ADNEX values were significantly higher in malignant versus benign, EOC versus non-EOC, and postmenopausal versus premenopausal groups (all P < 0.001). The ADNEX model achieved the highest AUC (0.954), with 94.1% sensitivity and 93.0% specificity at a pre‑specified cut‑off of 10%. Pairwise comparisons showed ADNEX significantly outperformed HE4(P < 0.001), CPHI (P = 0.008), ROMA (P = 0.004), and CA125 (P = 0.006).Conclusion  The ADNEX model demonstrates superior diagnostic accuracy in this high‑risk cohort. Integrated assessment combining serum biomarkers with ultrasonography is essential for accurate preoperative evaluation of pelvic masses.
SN  - 1471-2407
ER  -