Diagnostic performance of the ADNEX model compared with ROMA, RMI, and CPH‑I for ovarian cancer detection: a single‑center retrospective study.
- 1Tianjin Cancer Hospital Airport Hospital, Tianjin, 300000, China.
- 2Tianjin Cancer Hospital Airport Hospital, Tianjin, 300000, China. [email protected].
- 3Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300000, China. [email protected].
Abstract
Background
To evaluate the diagnostic performance of ROMA, RMI, CPH-I, and ADNEX models for ovarian cancer (OC).Methods
This single‑center retrospective study included 190 patients with pelvic masses (June 2024-January 2026). Serum CA125 and HE4 were measured, and ultrasonographic features were recorded. Patients were stratified by pathology into benign (n = 71) and malignant (n = 119) groups, giving a malignancy prevalence of 62.6%. Diagnostic accuracy of all models was compared using ROC curve analysis, optimal cut‑offs were determined via Youden's index.Results
Serum CA125, HE4, ROMA, RMI, CPH-I, and ADNEX values were significantly higher in malignant versus benign, EOC versus non-EOC, and postmenopausal versus premenopausal groups (all P < 0.001). The ADNEX model achieved the highest AUC (0.954), with 94.1% sensitivity and 93.0% specificity at a pre‑specified cut‑off of 10%. Pairwise comparisons showed ADNEX significantly outperformed HE4(P < 0.001), CPHI (P = 0.008), ROMA (P = 0.004), and CA125 (P = 0.006).Conclusion
The ADNEX model demonstrates superior diagnostic accuracy in this high‑risk cohort. Integrated assessment combining serum biomarkers with ultrasonography is essential for accurate preoperative evaluation of pelvic masses.
Related
- Comparative Diagnostic Performance of Three Commercial Real‐Time PCR Assays for the Detection of Mycobacterium tuberculosis Complex in Bronchial Washing Specimens: A Large Retrospective Study
- Performance Assessment of an Artificial Intelligence System Used for Case Detection in a Large Community-based Diabetic Retinopathy Screening Program: A Retrospective Diagnostic Accuracy Validation Study.
- Diagnostic Performance of 68Ga-PSMA-11 PET/CT Compared with Multiparametric MRI for Initial Local Staging of Prostate Cancer
- Performance of the NightWatch seizure detection device on the leg compared to the standard arm placement: A pilot study
- Diagnostic Performance of Radiofrequency Echographic Multi Spectrometry Compared with Dual-Energy X-Ray Absorptiometry: A Real-World Study
BibTeX
@article{feng2026diagnostic,
title = {{Diagnostic performance of the ADNEX model compared with ROMA, RMI, and CPH‑I for ovarian cancer detection: a single‑center retrospective study.}},
author = {Yaru Feng and Zhuo Zhang and Aiguo Zhu and Jian Wang},
journal = {BMC cancer},
year = {2026},
month = aug,
doi = {10.1186/s12885-026-16772-y},
url = {https://europepmc.org/article/MED/43079345},
note = {CC BY},
}
RIS
TY - JOUR
TI - Diagnostic performance of the ADNEX model compared with ROMA, RMI, and CPH‑I for ovarian cancer detection: a single‑center retrospective study.
AU - Yaru Feng
AU - Zhuo Zhang
AU - Aiguo Zhu
AU - Jian Wang
PY - 2026
DA - 2026/08/19
JO - BMC cancer
DO - 10.1186/s12885-026-16772-y
UR - https://europepmc.org/article/MED/43079345
AB - Background To evaluate the diagnostic performance of ROMA, RMI, CPH-I, and ADNEX models for ovarian cancer (OC).Methods This single‑center retrospective study included 190 patients with pelvic masses (June 2024-January 2026). Serum CA125 and HE4 were measured, and ultrasonographic features were recorded. Patients were stratified by pathology into benign (n = 71) and malignant (n = 119) groups, giving a malignancy prevalence of 62.6%. Diagnostic accuracy of all models was compared using ROC curve analysis, optimal cut‑offs were determined via Youden's index.Results Serum CA125, HE4, ROMA, RMI, CPH-I, and ADNEX values were significantly higher in malignant versus benign, EOC versus non-EOC, and postmenopausal versus premenopausal groups (all P < 0.001). The ADNEX model achieved the highest AUC (0.954), with 94.1% sensitivity and 93.0% specificity at a pre‑specified cut‑off of 10%. Pairwise comparisons showed ADNEX significantly outperformed HE4(P < 0.001), CPHI (P = 0.008), ROMA (P = 0.004), and CA125 (P = 0.006).Conclusion The ADNEX model demonstrates superior diagnostic accuracy in this high‑risk cohort. Integrated assessment combining serum biomarkers with ultrasonography is essential for accurate preoperative evaluation of pelvic masses.
SN - 1471-2407
ER -