Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 6 min ago
Peer-reviewedCC BY 4.0Epilepsy & Behavior Reports

Performance of the NightWatch seizure detection device on the leg compared to the standard arm placement: A pilot study

9 affiliations
  1. 1Academic Center for Epileptology (ACE), Kempenhaeghe and Maastricht University Medical Center, Maastricht, the Netherlands
  2. 2Department of Health Services Research, CAPHRI Care and Public Health Research Institute, Maastricht University, Maastricht, the Netherlands
  3. 3Mental Health and Neuroscience Research Institute, Faculty of Health Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands
  4. 4Trimbos Institute, Netherlands Institute of Mental Health and Addiction, Utrecht, the Netherlands
  5. 5Faculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
  6. 6Stichting Epilepsie Instellingen Nederland (SEIN), Heemstede and Zwolle, the Netherlands
  7. 7Department of Neurology, Leiden University Medical Centre (LUMC), the Netherlands
  8. 8UCL Queen Square Institute of Neurology, London, UK
  9. 9Department of Orthodontics, Ulm, University Ulm, Germany

Abstract

Nighttime monitoring is crucial for individuals with epilepsy, both to reduce the risk of injuries and to help prevent sudden unexpected death in epilepsy. NightWatch, a seizure detection device that can detect nocturnal seizures by using heart rate (HR) and movement parameters, has been shown to be effective when worn on the upper arm. This study piloted whether wearing NightWatch on the lower leg provides comparable seizure detection sensitivity.

In this prospective pilot study, NightWatch users wore a second device on the lower leg for four weeks. The positive percent agreement (PPA) was determined for the leg-worn NightWatch compared to the arm module. Differences in signal quality and time spent in rest state (sensor in horizontal position) were evaluated both per participant and across the population.

Ten participants (mean age: 12.5 years, range = 5–25) were included in the study. In total, 245 nights were analyzed. PPA ranged from 11.1% to 100%, yielding an overall mean PPA of 76.8% and median of 100%. The quality of HR signal for the leg module was comparable to the arm module (p = 0.1602). The leg module showed variability across patients and, overall, registered the rest state significantly less often than the arm module (p = 0.0059).

This pilot study demonstrated that NightWatch performance on the leg varies across participants, with comparable results to arm use in some participants but reduced accuracy in others. This study has been registered in the Overview of Medical Research in the Netherlands (OMON) (NL-OMON57506).

Related

  1. Clinical Performance of the Elecsys HCV Duo Immunoassay Compared with a Standard-of-Care Algorithm Using Alinity Anti-HCV Screening and HCV RNA Confirmation
    Jaeeun Yoo, Hye-Sun Park, JoungOk Kim +6
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Diagnostic performance of the ADNEX model compared with ROMA, RMI, and CPH‑I for ovarian cancer detection: a single‑center retrospective study.
    Yaru Feng, Zhuo Zhang, Aiguo Zhu +1
    BMC cancerPeer-reviewedCC BYFull textOncologyEurope PMC
  3. Protocol for a feasibility randomised controlled trial of administering daytime only enteral feeding compared to standard continuous enteral feeding, to reduce delirium in mechanically ventilated, critically ill adults, with qualitative and circadian mechanistic sub-studies
    Jessie Welbourne, Helen Neilens, Liesl Wandrag +13
    Journal of the Intensive Care SocietyPeer-reviewedLicence not statedFull textGeneral medicinePMC
  4. Does omission of a loose seton before sphincter-preserving surgery achieve non-inferior fistula closure compared with routine loose seton placement in adults with single-tract cryptoglandular anal fistula in the Netherlands? Study protocol for the SETON multicentre randomised controlled non-inferiority trial and cost-utility analysis
    Ahmed A Elwakel, Pieter Van Hagen, Ruben Veldkamp +3
    BMJ OpenPeer-reviewedCC BY 4.0Surgery & anaesthesiaCrossref
  5. Weight reduction intervention effectively reduce weight compared with standard care in people living with HIV gaining weight after dolutegravir initiation
    Pasook Sitthilok, Romanee Chaiwarith, Supawan Buranapin +1
    Scientific ReportsPeer-reviewedCC BYFull textInfectious diseaseDOAJ
BibTeX
@article{krom2026performance,
  title = {{Performance of the NightWatch seizure detection device on the leg compared to the standard arm placement: A pilot study}},
  author = {Megan Krom and Eefke M. Lemmen and Silvia M.A.A. Evers and Richard H.C. Lazeron and Marian H.J.M. Majoie and Roland D. Thijs and Johannes P. van Dijk},
  journal = {Epilepsy \& Behavior Reports},
  year = {2026},
  month = oct,
  doi = {10.1016/j.ebr.2026.100903},
  url = {https://doi.org/10.1016/j.ebr.2026.100903},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Performance of the NightWatch seizure detection device on the leg compared to the standard arm placement: A pilot study
AU  - Megan Krom
AU  - Eefke M. Lemmen
AU  - Silvia M.A.A. Evers
AU  - Richard H.C. Lazeron
AU  - Marian H.J.M. Majoie
AU  - Roland D. Thijs
AU  - Johannes P. van Dijk
PY  - 2026
DA  - 2026/10/29
JO  - Epilepsy & Behavior Reports
DO  - 10.1016/j.ebr.2026.100903
UR  - https://doi.org/10.1016/j.ebr.2026.100903
AB  - Nighttime monitoring is crucial for individuals with epilepsy, both to reduce the risk of injuries and to help prevent sudden unexpected death in epilepsy. NightWatch, a seizure detection device that can detect nocturnal seizures by using heart rate (HR) and movement parameters, has been shown to be effective when worn on the upper arm. This study piloted whether wearing NightWatch on the lower leg provides comparable seizure detection sensitivity.  In this prospective pilot study, NightWatch users wore a second device on the lower leg for four weeks. The positive percent agreement (PPA) was determined for the leg-worn NightWatch compared to the arm module. Differences in signal quality and time spent in rest state (sensor in horizontal position) were evaluated both per participant and across the population.  Ten participants (mean age: 12.5 years, range = 5–25) were included in the study. In total, 245 nights were analyzed. PPA ranged from 11.1% to 100%, yielding an overall mean PPA of 76.8% and median of 100%. The quality of HR signal for the leg module was comparable to the arm module (p = 0.1602). The leg module showed variability across patients and, overall, registered the rest state significantly less often than the arm module (p = 0.0059).  This pilot study demonstrated that NightWatch performance on the leg varies across participants, with comparable results to arm use in some participants but reduced accuracy in others. This study has been registered in the Overview of Medical Research in the Netherlands (OMON) (NL-OMON57506).
SN  - 2589-9864
ER  -