Effectiveness and Safety of RHA4 Versus Comparator Product for Midface Volume Deficiency: A Randomized, Prospective, Multicenter Clinical Study.
9 affiliations
- 1AVA MD Santa Monica Santa Monica California USA.
- 2Cosmetic Laser Dermatology San Diego California USA.
- 3The Clinical Testing Center of Beverly Hills Encino California USA.
- 4Aesthetic Solutions Chapel Hill North Carolina USA.
- 5University of South Florida Bradenton Florida USA.
- 6Skin Research Institute LLC Coral Gables Florida USA.
- 7SkinCare Physicians Chestnut Hill Massachusetts USA.
- 8DeNova Research Chicago Illinois USA.
- 9TEOXANE SA Geneva Switzerland.
Abstract
Background
Hyaluronic acid (HA) dermal fillers are widely used to correct age-related midface volume deficits and improve self-perceived attractiveness. TEOSYAL RHA 4 (also FDA-approved as RHA Dynamic Volume) (RHA4) is a high-strength, moderate-stretch HA volumizing injectable designed to maintain facial dynamics.Objectives
To evaluate the effectiveness and safety of RHA4 versus an active comparator (Juvéderm Voluma XC) for correction of midface volume deficits (MVD).Methods
In this controlled, randomized (3:1), blinded live-evaluator, multicenter prospective clinical study, the primary outcome was the change from baseline in Teoxane Midface Volume Deficit Scale (TMVDS) score, while the co-primary endpoint was the proportion of responders with ≥ 1-grade improvement on the TMVDS at 8 weeks post-treatment.Results
Overall, 201 subjects were enrolled (152 RHA4; 49 comparator); 74.6% received multilayer injections in deep and superficial midface fat pads. Mean TMVDS change at 8 weeks was -1.3 ± 0.8 with RHA4 and -1.3 ± 0.6 with comparator (p = 0.377; upper 95% CI bound < 0.5, non-inferiority demonstrated). The proportion of subjects achieving ≥ 1-grade improvement (responder rate) was 87.0% (RHA4) and 90.5% (comparator) (p = 0.786); the co-primary endpoint was met (comparator responder rate > 70%). TMVDS responder rate following RHA4 treatment remained above 65.6% for 52 weeks, while subject-assessed aesthetic improvement and satisfaction remained above 81.3% and 82.8%, respectively. RHA4 exhibited a good safety profile similar to the comparator.Conclusions
RHA4 was shown to be as effective as the active comparator for correction of MVD, providing sustained aesthetic outcomes, high satisfaction, and good tolerability.
Related
- NMA plus antitumor therapy versus antitumor therapy alone in patients with BCLC stage B or C hepatocellular carcinoma and pre-cachexia or cachexia: protocol for a prospective, multicenter, randomized, open-label phase II trial
- Efficacy and safety of Jiashen tablets for ischemic heart failure with yang-qi deficiency and blood stasis syndrome: protocol for a multicenter phase II randomized, double-blind, placebo-controlled trial
- Real-world effectiveness and safety of enavogliflozin in patients with type 2 diabetes: A 24-week prospective multicenter observational study in Korea.
- Long‐Term Five‐Year Effectiveness of Tenofovir Alafenamide in Japanese Patients With Chronic Hepatitis B: A Prospective Multicenter Registry Study
- Effectiveness of a pharmacist-led protocol to manage cystitis in women, in France: the PharmaCyst’ open-label, multicenter, randomized, controlled, cluster study
BibTeX
@article{shamban2026effectiveness,
title = {{Effectiveness and Safety of RHA4 Versus Comparator Product for Midface Volume Deficiency: A Randomized, Prospective, Multicenter Clinical Study.}},
author = {Ava Shamban and Sabrina Fabi and John Joseph and Sue Ellen Cox and Susan Weinkle and Joely Kaufman-Janette and Jeffrey Dover and Steven Dayan and Laura Picault and Alice Melotti and Stefania Ballarini},
journal = {Journal of cosmetic dermatology},
year = {2026},
month = aug,
doi = {10.1111/jocd.71113},
url = {https://europepmc.org/article/MED/43047104},
note = {CC BY},
}
RIS
TY - JOUR
TI - Effectiveness and Safety of RHA4 Versus Comparator Product for Midface Volume Deficiency: A Randomized, Prospective, Multicenter Clinical Study.
AU - Ava Shamban
AU - Sabrina Fabi
AU - John Joseph
AU - Sue Ellen Cox
AU - Susan Weinkle
AU - Joely Kaufman-Janette
AU - Jeffrey Dover
AU - Steven Dayan
AU - Laura Picault
AU - Alice Melotti
AU - Stefania Ballarini
PY - 2026
DA - 2026/08/17
JO - Journal of cosmetic dermatology
DO - 10.1111/jocd.71113
UR - https://europepmc.org/article/MED/43047104
AB - Background Hyaluronic acid (HA) dermal fillers are widely used to correct age-related midface volume deficits and improve self-perceived attractiveness. TEOSYAL RHA 4 (also FDA-approved as RHA Dynamic Volume) (RHA4) is a high-strength, moderate-stretch HA volumizing injectable designed to maintain facial dynamics.Objectives To evaluate the effectiveness and safety of RHA4 versus an active comparator (Juvéderm Voluma XC) for correction of midface volume deficits (MVD).Methods In this controlled, randomized (3:1), blinded live-evaluator, multicenter prospective clinical study, the primary outcome was the change from baseline in Teoxane Midface Volume Deficit Scale (TMVDS) score, while the co-primary endpoint was the proportion of responders with ≥ 1-grade improvement on the TMVDS at 8 weeks post-treatment.Results Overall, 201 subjects were enrolled (152 RHA4; 49 comparator); 74.6% received multilayer injections in deep and superficial midface fat pads. Mean TMVDS change at 8 weeks was -1.3 ± 0.8 with RHA4 and -1.3 ± 0.6 with comparator (p = 0.377; upper 95% CI bound < 0.5, non-inferiority demonstrated). The proportion of subjects achieving ≥ 1-grade improvement (responder rate) was 87.0% (RHA4) and 90.5% (comparator) (p = 0.786); the co-primary endpoint was met (comparator responder rate > 70%). TMVDS responder rate following RHA4 treatment remained above 65.6% for 52 weeks, while subject-assessed aesthetic improvement and satisfaction remained above 81.3% and 82.8%, respectively. RHA4 exhibited a good safety profile similar to the comparator.Conclusions RHA4 was shown to be as effective as the active comparator for correction of MVD, providing sustained aesthetic outcomes, high satisfaction, and good tolerability.
SN - 1473-2130
SN - 1473-2165
ER -