Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BY 4.0Journal of Interventional Cardiac Electrophysiology

Comparison of general anesthesia and deep sedation for complex atrial ablation procedures using a lattice-tip catheter with monopolar pulsed field and radiofrequency ablation

2 more authors
  1. 1Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010 Switzerland
  2. 2SITEM Center for Translational Medicine and Biomedical Entrepreneurship, University of Bern, Bern, Switzerland

Abstract

Background: A dual-energy lattice-tip catheter with full 3D integration using monopolar pulsed field ablation (PFA) can result in significant skeletal muscle recruitment. It has therefore mainly been utilized under general anesthesia (GA), but procedures might also be possible using propofol-based deep sedation (DS).

Methods: Consecutive patients undergoing ablation of atrial fibrillation or left atrial flutter using the lattice-tip catheter were enrolled. The use of PFA and/or RFA was based on anatomical location. Procedural characteristics and outcomes were compared between patients with GA and those with DS.

Results: A total of 101 patients underwent ablation, 54% were treated under GA and 47% received DS (median age 69 years, 40% women, 85% redo-procedures). The arrhythmia subtypes were atrial fibrillation in 26%, left atrial flutter in 44%, and both in 31%. In addition to PVI, a total of 150 left atrial extra-PV lesion sets were performed, and CTI ablation in 59 patients. Median laboratory occupancy time was significantly shorter in the deep sedation group (GA 203 min [157–231] vs. DS 162 min [IQR 148–196], p = 0.003). No conversions from deep sedation to general anesthesia were required. Freedom from atrial arrhythmia recurrence was higher in the GA group (76% vs. 49% in the DS group, p = 0.038). After adjustment for confounders, the association attenuated but remained directionally consistent in favor of GA (HR 0.47 for recurrence, p = 0.061).

Conclusions: Complex atrial ablation using a dual-energy lattice-tip catheter appears safe under both GA and DS. Despite higher baseline risk, GA patients had fewer arrhythmia recurrences at one year.

Graphical abstract:

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10840-026-02397-5.

Related

  1. Auditory Evoked Potentials Across Cognitive States: Awake, Sleep, Sedation, and Anesthesia
    Zhibin Zhou, Nayana Singh, Miguel Padilla +3
    Medical sciences (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Management of Early Childhood Caries in a Child with Angelman Syndrome under General Anesthesia and Oral Sedation
    Dempsy Chengappa, Rahul Koul, Anoop Sharma +1
    Journal of Primary Care Dentistry and Oral HealthPeer-reviewedCC BY-NC-SAFull textGeneral medicineDOAJ
  3. Electrophysiology Team-Administered Conscious Sedation for Pulsed-Field Versus Radiofrequency Ablation in Atrial Fibrillation.
    Li Cheng, Yu Xia, Zhicheng Hu +9
    Anesthesiology research and practicePeer-reviewedCC BYFull textCardiovascular medicineEurope PMCPMC
  4. Current Approaches to Sedation and Anesthesia in Endoscopy Units: Integrating Pharmacology, Monitoring, and Patient Safety
    Fatih Sahin, Ali Fuat Erdem, Benedikt Preckel
    The Turkish Journal of GastroenterologyPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  5. General Anesthesia vs Procedural Sedation and Post-Thrombectomy Stress Hyperglycemia: A Retrospective Cohort Study
    A. Laichetty, K. Zhou, W. C. Broaddus
    medRxivPreprintCC BY-NC-NDFull textSurgery & anaesthesiamedRxiv
BibTeX
@article{storz2026comparison,
  title = {{Comparison of general anesthesia and deep sedation for complex atrial ablation procedures using a lattice-tip catheter with monopolar pulsed field and radiofrequency ablation}},
  author = {Theresa Storz and Thomas Kueffer and Gregor Thalmann and Corinne Jufer and Valon Spahiu and Claudia Herrera and Boldizsar Kovacs and Nikola A. Kozhuharov and Helge Servatius and Andreas Haeberlin and Fabian Noti and Hildegard Tanner and Laurent Roten and Tobias Reichlin},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2026},
  month = jul,
  doi = {10.1007/s10840-026-02397-5},
  url = {https://doi.org/10.1007/s10840-026-02397-5},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Comparison of general anesthesia and deep sedation for complex atrial ablation procedures using a lattice-tip catheter with monopolar pulsed field and radiofrequency ablation
AU  - Theresa Storz
AU  - Thomas Kueffer
AU  - Gregor Thalmann
AU  - Corinne Jufer
AU  - Valon Spahiu
AU  - Claudia Herrera
AU  - Boldizsar Kovacs
AU  - Nikola A. Kozhuharov
AU  - Helge Servatius
AU  - Andreas Haeberlin
AU  - Fabian Noti
AU  - Hildegard Tanner
AU  - Laurent Roten
AU  - Tobias Reichlin
PY  - 2026
DA  - 2026/07/07
JO  - Journal of Interventional Cardiac Electrophysiology
DO  - 10.1007/s10840-026-02397-5
UR  - https://doi.org/10.1007/s10840-026-02397-5
AB  - Background: A dual-energy lattice-tip catheter with full 3D integration using monopolar pulsed field ablation (PFA) can result in significant skeletal muscle recruitment. It has therefore mainly been utilized under general anesthesia (GA), but procedures might also be possible using propofol-based deep sedation (DS).  Methods: Consecutive patients undergoing ablation of atrial fibrillation or left atrial flutter using the lattice-tip catheter were enrolled. The use of PFA and/or RFA was based on anatomical location. Procedural characteristics and outcomes were compared between patients with GA and those with DS.  Results: A total of 101 patients underwent ablation, 54% were treated under GA and 47% received DS (median age 69 years, 40% women, 85% redo-procedures). The arrhythmia subtypes were atrial fibrillation in 26%, left atrial flutter in 44%, and both in 31%. In addition to PVI, a total of 150 left atrial extra-PV lesion sets were performed, and CTI ablation in 59 patients. Median laboratory occupancy time was significantly shorter in the deep sedation group (GA 203 min [157–231] vs. DS 162 min [IQR 148–196], p = 0.003). No conversions from deep sedation to general anesthesia were required. Freedom from atrial arrhythmia recurrence was higher in the GA group (76% vs. 49% in the DS group, p = 0.038). After adjustment for confounders, the association attenuated but remained directionally consistent in favor of GA (HR 0.47 for recurrence, p = 0.061).  Conclusions: Complex atrial ablation using a dual-energy lattice-tip catheter appears safe under both GA and DS. Despite higher baseline risk, GA patients had fewer arrhythmia recurrences at one year.  Graphical abstract:  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10840-026-02397-5.
SN  - 1383-875X
SN  - 1572-8595
ER  -