Flow and transport characteristics of hydrogen in a square-spiral Knudsen pump with coupled thermal transpiration and Poiseuille flow
Abstract
Gas transport driven by thermal transpiration under temperature gradients, known as a Knudsen pump, has shown strong potential in gas separation and delivery applications. However, its performance and operational stability are strongly affected by structural design, system integration, and manufacturing complexity, highlighting the need for efficient and manufacturable multi-stage configurations. In this study, a novel spiral-structured Knudsen pump is proposed. Within the microchannels, a temperature gradient drives gas from the low- to high-temperature region, inducing pressure rise and thermal transpiration. In the main channel, a pressure gradient drives gas from the high- to low-temperature region, forming Poiseuille flow. Numerical methods are employed to investigate the flow mechanisms, and the effects of varying the numbers of series and parallel microchannels on gas transmission behavior are evaluated. The results indicate that bends of the main channel lead to nonlinear variations in pressure and temperature, as well as flow deceleration in the curved regions. Increasing the number of serial channels reduces the pressure load across the microchannel, thereby enhancing the overall transport performance. For instance, a ten-stage serial configuration improves performance by 3.35% compared with the four-stage case, reaching 3.10E10-7 kg/(m*s). In contrast, increasing the number of parallel microchannels reduces pressure loading while enhancing gas rarefaction, thereby strengthening thermal transpiration. A five-stage parallel configuration yields an 70.80% improvement over the two-stage case, reaching 3.07E10-7 kg/(m*s). These results provide valuable guidance for the design and fabrication of high-performance Knudsen pumps.
Related
- Coupled Effects of Biofilm Dynamics and Flow on Hydrogen Transport in a Hydrogen-Generating Fracture
- Quantum-Entangled Four-Proton Waltz of Anomalous Transport in Water Hydrogen Bond Network
- Laser Shock Peening in Hydrogen Environments: Coupled Stress Transport Trapping Mechanisms and Application Gaps
- Effects of Corner Radius and Knudsen Number on Rarefied Gas Flow in a Lid-Driven Cavity
- Pressure-drop localization and momentum insulation in liquid-gas coexistence Poiseuille flow
BibTeX
@misc{huang2026flow,
title = {{Flow and transport characteristics of hydrogen in a square-spiral Knudsen pump with coupled thermal transpiration and Poiseuille flow}},
author = {Yawei Huang and Jianjun Ye and Junlong Xie and Jian Xiao and Dinggen Li and Xuesong He},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.04288},
eprint = {2611.04288},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.04288},
}
RIS
TY - UNPB
TI - Flow and transport characteristics of hydrogen in a square-spiral Knudsen pump with coupled thermal transpiration and Poiseuille flow
AU - Yawei Huang
AU - Jianjun Ye
AU - Junlong Xie
AU - Jian Xiao
AU - Dinggen Li
AU - Xuesong He
PY - 2026
DA - 2026/11/03
PB - arXiv
DO - 10.48550/arxiv.2611.04288
UR - https://arxiv.org/abs/2611.04288
AB - Gas transport driven by thermal transpiration under temperature gradients, known as a Knudsen pump, has shown strong potential in gas separation and delivery applications. However, its performance and operational stability are strongly affected by structural design, system integration, and manufacturing complexity, highlighting the need for efficient and manufacturable multi-stage configurations. In this study, a novel spiral-structured Knudsen pump is proposed. Within the microchannels, a temperature gradient drives gas from the low- to high-temperature region, inducing pressure rise and thermal transpiration. In the main channel, a pressure gradient drives gas from the high- to low-temperature region, forming Poiseuille flow. Numerical methods are employed to investigate the flow mechanisms, and the effects of varying the numbers of series and parallel microchannels on gas transmission behavior are evaluated. The results indicate that bends of the main channel lead to nonlinear variations in pressure and temperature, as well as flow deceleration in the curved regions. Increasing the number of serial channels reduces the pressure load across the microchannel, thereby enhancing the overall transport performance. For instance, a ten-stage serial configuration improves performance by 3.35% compared with the four-stage case, reaching 3.10E10-7 kg/(m*s). In contrast, increasing the number of parallel microchannels reduces pressure loading while enhancing gas rarefaction, thereby strengthening thermal transpiration. A five-stage parallel configuration yields an 70.80% improvement over the two-stage case, reaching 3.07E10-7 kg/(m*s). These results provide valuable guidance for the design and fabrication of high-performance Knudsen pumps.
ER -