Abstract

BackgroundRobot-assisted cannulated-screw fixation may improve trajectory control and reduce fluoroscopic acquisitions during femoral neck fracture treatment; however, its comparative clinical benefits and early learning curve remain insufficiently characterized.MethodsThis single-centre retrospective cohort study included 61 patients aged 18–65 years with acute Pauwels type II or III femoral neck fractures treated between January 2023 and January 2025. Twenty-one patients underwent robot-assisted fixation and 40 underwent conventional freehand fixation with three cannulated screws. Perioperative, radiographic, and 12-month clinical outcomes were compared. The learning curve was assessed using Spearman rank correlation, simple linear regression, and mean-centred cumulative sum (CUSUM) analysis.ResultsBaseline characteristics were comparable between groups. Compared with conventional freehand fixation, robot-assisted fixation was associated with shorter total operative time., fewer fluoroscopic acquisitions.., and lower intraoperative blood loss… Robot-assisted fixation was associated with more favourable screw-placement parameters and less femoral-neck shortening. Postoperative day-1 pain scores assessed using VAS were lower in the robot-assisted group. HHS values were higher at 1 month and final follow-up. Fracture-healing time and neck–shaft angle did not differ significantly between groups. Only one postoperative complication occurred during follow-up, consisting of screw back-out in one patient in the freehand group; therefore, comparative safety conclusions were not supported. Within the robot-assisted cohort, case number was inversely associated with total operative time, puncture workflow time, and fluoroscopy use. The mean-centred CUSUM trajectories reached sample-specific maxima at cases 7, 6, and 6, respectively, before showing overall downward trajectories.ConclusionRobot-assisted percutaneous cannulated-screw fixation was associated with greater procedural efficiency and more favourable screw-placement parameters than conventional freehand fixation. Statistically significant differences were observed in postoperative pain, HHS, and femoral-neck shortening; however, the clinical importance of these differences remains uncertain. Operative performance improved across the observed sequence of robot-assisted cases, although no validated proficiency threshold could be established from this cohort.

Related

  1. Early clinical and radiographic outcomes of robot-assisted femoral neck system fixation combined with an additional cannulated compression screw for garden IV femoral neck fractures in young and middle-aged adults: a propensity score-matched retrospective cohort study.
    Wu Fengqin, Aihelamu Tueraili, Yaqiong Zhao
    Frontiers in surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Fully Threaded Versus Partially Threaded Cannulated Screws in the Treatment of Nondisplaced or Valgus-Impacted Geriatric Femoral Neck Fractures: A Retrospective Cohort Study
    Journal of the American Academy of Orthopaedic Surgeons. Global research & reviewsPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. Machine learning-based prediction of clinical outcomes and left ventricular ejection fraction improvement after percutaneous coronary intervention in patients with reduced ejection fraction.
    Lioz Steinbuch, Edward Itelman, Yuval Altman +11
    European heart journal. Digital healthPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
  4. Percutaneous Versus Open Approach to Intramedullary Nailing of Metacarpal Shaft Fractures: A Comparison of 12 Week Functional Outcomes.
    Stephen M Himmelberg, Alexander D Jeffs, Nicholas C Bank +3
    Journal of hand surgery global onlinePeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  5. Achieved LDL-C Levels and Clinical Outcomes Following Percutaneous Coronary Intervention with Drug-Coated Balloons for De Novo Coronary Lesions
    Takashi Nagasaka, Shunichiro Ishio, Ryota Taniuchi +4
    Journal of Atherosclerosis and ThrombosisPeer-reviewedLicence not statedFull textCardiovascular medicineJ-STAGE
BibTeX
@article{gong2026clinical,
  title = {{Clinical outcomes and learning curve of robot-assisted percutaneous cannulated screw fixation for femoral neck fractures}},
  author = {Hu Gong and Yang Shu and Te Li and Jibin Chen and Fanghui Zhang},
  journal = {Frontiers in Surgery},
  year = {2026},
  month = oct,
  doi = {10.3389/fsurg.2026.1980063},
  url = {https://doi.org/10.3389/fsurg.2026.1980063},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Clinical outcomes and learning curve of robot-assisted percutaneous cannulated screw fixation for femoral neck fractures
AU  - Hu Gong
AU  - Yang Shu
AU  - Te Li
AU  - Jibin Chen
AU  - Fanghui Zhang
PY  - 2026
DA  - 2026/10/26
JO  - Frontiers in Surgery
DO  - 10.3389/fsurg.2026.1980063
UR  - https://doi.org/10.3389/fsurg.2026.1980063
AB  - BackgroundRobot-assisted cannulated-screw fixation may improve trajectory control and reduce fluoroscopic acquisitions during femoral neck fracture treatment; however, its comparative clinical benefits and early learning curve remain insufficiently characterized.MethodsThis single-centre retrospective cohort study included 61 patients aged 18–65 years with acute Pauwels type II or III femoral neck fractures treated between January 2023 and January 2025. Twenty-one patients underwent robot-assisted fixation and 40 underwent conventional freehand fixation with three cannulated screws. Perioperative, radiographic, and 12-month clinical outcomes were compared. The learning curve was assessed using Spearman rank correlation, simple linear regression, and mean-centred cumulative sum (CUSUM) analysis.ResultsBaseline characteristics were comparable between groups. Compared with conventional freehand fixation, robot-assisted fixation was associated with shorter total operative time., fewer fluoroscopic acquisitions.., and lower intraoperative blood loss… Robot-assisted fixation was associated with more favourable screw-placement parameters and less femoral-neck shortening. Postoperative day-1 pain scores assessed using VAS were lower in the robot-assisted group. HHS values were higher at 1 month and final follow-up. Fracture-healing time and neck–shaft angle did not differ significantly between groups. Only one postoperative complication occurred during follow-up, consisting of screw back-out in one patient in the freehand group; therefore, comparative safety conclusions were not supported. Within the robot-assisted cohort, case number was inversely associated with total operative time, puncture workflow time, and fluoroscopy use. The mean-centred CUSUM trajectories reached sample-specific maxima at cases 7, 6, and 6, respectively, before showing overall downward trajectories.ConclusionRobot-assisted percutaneous cannulated-screw fixation was associated with greater procedural efficiency and more favourable screw-placement parameters than conventional freehand fixation. Statistically significant differences were observed in postoperative pain, HHS, and femoral-neck shortening; however, the clinical importance of these differences remains uncertain. Operative performance improved across the observed sequence of robot-assisted cases, although no validated proficiency threshold could be established from this cohort.
SN  - 2296-875X
ER  -