Background
Garden IV femoral neck fractures in young and middle-aged adults are highly unstable and prone to shortening, nonunion, and femoral head necrosis. We compared robot-assisted femoral neck system (FNS) fixation plus an additional cannulated compression screw (CCS) in a multiplanar configuration with robot-assisted FNS fixation alone.Methods
This retrospective cohort included 172 patients aged 18-60 years who were treated from June 2024 to June 2025; 82 underwent robot-assisted FNS plus CCS fixation and 90 underwent robot-assisted FNS fixation alone. After 1:1 nearest-neighbor propensity score matching without replacement (caliper, 0.2 standard deviations of the logit propensity score), 67 matched pairs were analyzed. Femoral neck shortening at 12 months was defined as the primary analytic endpoint for this report; perioperative, rehabilitation, other radiographic, functional, and complication outcomes were secondary or exploratory.Results
FNS plus CCS required longer operative time (81.67 ± 7.62 vs. 68.67 ± 7.51 min), more fluoroscopic exposures and guidewire adjustments, and a longer total incision (all P < 0.05). It was associated with earlier full weight-bearing (10.74 ± 1.42 vs. 12.47 ± 1.34 weeks), shorter fracture-healing time (4.69 ± 0.52 vs. 5.25 ± 0.43 months), less femoral neck shortening at 12 months (4.46 ± 1.35 vs. 6.08 ± 1.31 mm), and a lower rate of moderate shortening (34.3% vs. 73.1%; all P < 0.001). HHS was higher at 6 and 12 months and VAS was lower at 12 months in the combined group. Any complication occurred in 1.5% versus 10.4% (exact P = 0.070; conditional matched OR, 0.14; exact 95% CI, 0.003-1.11), indicating substantial uncertainty in the safety comparison.Conclusions
In this propensity score-matched retrospective cohort, robot-assisted FNS plus an additional CCS was associated with less femoral neck shortening, earlier full weight-bearing, shorter fracture-healing time, and better later functional recovery, at the cost of greater operative complexity. Because the safety analysis was underpowered and follow-up was limited to 12 months, these findings should be interpreted cautiously and do not establish long-term safety or femoral head necrosis risk; prospective multicenter studies with longer follow-up are required.
Related
- Fully Threaded Versus Partially Threaded Cannulated Screws in the Treatment of Nondisplaced or Valgus-Impacted Geriatric Femoral Neck Fractures: A Retrospective Cohort Study
- Quantitative assessment of the influence of tapered dies and compaction position on the propensity of lamination due to air entrapment during pharmaceutical compression
- Agreement and Systematic Differences Between Intraoperative ROSA Hip-Knee-Ankle Measurements and Standing Radiographic Alignment After Robotic-Assisted Total Knee Arthroplasty: A Retrospective Agreement Study
- Echinococcus granulosus Genotype and Surgical Outcomes After Cystic Echinococcosis Surgery: A Propensity-Score-Adjusted Retrospective Pilot Cohort Study
- Minimally Invasive Coronary Artery Bypass Grafting in Patients With Prior Myocardial Infarction: A Propensity Score-Matched Retrospective Study
BibTeX
@article{fengqin2026early,
title = {{Early clinical and radiographic outcomes of robot-assisted femoral neck system fixation combined with an additional cannulated compression screw for garden IV femoral neck fractures in young and middle-aged adults: a propensity score-matched retrospective cohort study.}},
author = {Wu Fengqin and Aihelamu Tueraili and Yaqiong Zhao},
journal = {Frontiers in surgery},
year = {2026},
month = oct,
doi = {10.3389/fsurg.2026.1958968},
url = {https://europepmc.org/article/MED/42903420},
note = {CC BY},
}
RIS
TY - JOUR
TI - Early clinical and radiographic outcomes of robot-assisted femoral neck system fixation combined with an additional cannulated compression screw for garden IV femoral neck fractures in young and middle-aged adults: a propensity score-matched retrospective cohort study.
AU - Wu Fengqin
AU - Aihelamu Tueraili
AU - Yaqiong Zhao
PY - 2026
DA - 2026/10/19
JO - Frontiers in surgery
DO - 10.3389/fsurg.2026.1958968
UR - https://europepmc.org/article/MED/42903420
AB - Background Garden IV femoral neck fractures in young and middle-aged adults are highly unstable and prone to shortening, nonunion, and femoral head necrosis. We compared robot-assisted femoral neck system (FNS) fixation plus an additional cannulated compression screw (CCS) in a multiplanar configuration with robot-assisted FNS fixation alone.Methods This retrospective cohort included 172 patients aged 18-60 years who were treated from June 2024 to June 2025; 82 underwent robot-assisted FNS plus CCS fixation and 90 underwent robot-assisted FNS fixation alone. After 1:1 nearest-neighbor propensity score matching without replacement (caliper, 0.2 standard deviations of the logit propensity score), 67 matched pairs were analyzed. Femoral neck shortening at 12 months was defined as the primary analytic endpoint for this report; perioperative, rehabilitation, other radiographic, functional, and complication outcomes were secondary or exploratory.Results FNS plus CCS required longer operative time (81.67 ± 7.62 vs. 68.67 ± 7.51 min), more fluoroscopic exposures and guidewire adjustments, and a longer total incision (all P < 0.05). It was associated with earlier full weight-bearing (10.74 ± 1.42 vs. 12.47 ± 1.34 weeks), shorter fracture-healing time (4.69 ± 0.52 vs. 5.25 ± 0.43 months), less femoral neck shortening at 12 months (4.46 ± 1.35 vs. 6.08 ± 1.31 mm), and a lower rate of moderate shortening (34.3% vs. 73.1%; all P < 0.001). HHS was higher at 6 and 12 months and VAS was lower at 12 months in the combined group. Any complication occurred in 1.5% versus 10.4% (exact P = 0.070; conditional matched OR, 0.14; exact 95% CI, 0.003-1.11), indicating substantial uncertainty in the safety comparison.Conclusions In this propensity score-matched retrospective cohort, robot-assisted FNS plus an additional CCS was associated with less femoral neck shortening, earlier full weight-bearing, shorter fracture-healing time, and better later functional recovery, at the cost of greater operative complexity. Because the safety analysis was underpowered and follow-up was limited to 12 months, these findings should be interpreted cautiously and do not establish long-term safety or femoral head necrosis risk; prospective multicenter studies with longer follow-up are required.
SN - 2296-875X
ER -