Skip to content
DraconiticResearch
Search Sources API
197,785 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BYBMC cardiovascular disorders

Prospective multicenter feasibility study of omnipolar near-field peak-frequency mapping for slow-pathway localization in typical atrioventricular nodal re-entrant tachycardia.

2 more authors
8 affiliations
  1. 1Cardiology Florence II, Department of Medical Specialties, Florence, Italy.
  2. 2Pediatric Cardiology Unit, Meyer Children's Hospital IRCCS, Florence, Italy.
  3. 3Department of Cardiovascular and Thoracic Sciences, Catholic University of the Sacred Heart, Rome, Italy.
  4. 4Department of Cardiology, Sandro Pertini Hospital, Rome, Italy.
  5. 5Santa Maria Della Misericordia Hospital, Rovigo, Italy.
  6. 6Abbott Medical, Viale Thomas Alva Edison 110, Sesto San Giovanni, 20099, MI, Italy.
  7. 7University of Applied Sciences, An der Karlstadt 8, 27568, Bremerhaven, Germany. [email protected].
  8. 8Medical Faculty, University of Kiel, Christian-Albrechts-Platz 4, 24118, Kiel, Germany. [email protected].

Abstract

Background

Slow-pathway (SP) ablation is the established therapy for atrioventricular nodal re-entrant tachycardia (AVNRT). While conventional anatomical and electrogram-guided approaches are effective, SP localization may be challenging in a subset of procedures. Omnipolar near-field (OTNF) peak frequency (PF) mapping has been proposed as a signal-based approach to support SP localization; however, prospective multicenter data remain limited.Methods

Fifty consecutive adults with inducible typical AVNRT underwent catheter ablation in three Italian hospitals. High-density right atrial mapping was performed during sinus rhythm using a 16-pole grid catheter (Advisor™ HD Grid) with OTNF on the EnSite X system. PF maps were generated (high-frequency threshold > 250 Hz), and RF applications were delivered to the region of highest PF. Voltage maps were also created to delineate low-voltage bridge (LVB) regions (typically 0.04-2 mV) for retrospective overlap/localization analyses; LVB was not used to select ablation targets.Results

Acute procedural success was achieved in all patients, with no procedural complications. The effective ablation site (junctional beats with subsequent SP modification and/or non-inducibility) corresponded to the highest PF region in 45/50 patients (90%). In a retrospective overlap/localization analysis, the effective site fell within the LVB region in 36/50 patients (72%); concordance between PF-defined and LVB-defined regions at the effective site was observed in 35/50 patients (70%). Mean PF in the SP target region was 424 ± 86 Hz versus 272 ± 57 Hz in surrounding tissue (P < 0.05 on paired testing). Exploratory ROC analysis yielded an AUC of 0.937 with an optimal cutoff of 357 Hz (sensitivity 0.87; specificity 0.94); these estimates should be interpreted cautiously because PF guided RF target selection (incorporation/target-selection bias).Conclusion

In this prospective multicenter cohort, OTNF-derived PF mapping was feasible and reproducibly identified a discrete region used to guide SP ablation in typical AVNRT. ROC-derived thresholds and performance estimates are exploratory and require independent validation in cohorts where ablation targets are not selected using PF criteria.

Related

  1. Efficacy and safety of low-power (20 W) catheter ablation for typical atrioventricular nodal reentrant tachycardia: a prospective multicenter study
    Lae-Young Jung, Chang Hee Kwon, In Geol Song +2
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Cardiovascular medicineCrossref
  2. Persistence of atrioventricular nodal re-entrant tachycardia during ventricular fibrillation.
    Laura Simon, Thomas Rosseel, Tomas Robyns +1
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  3. Unveiling Asymptomatic Atrioventricular Reciprocating Tachycardia in a Patient With Wolff-Parkinson-White Syndrome and Multiple Sclerosis
    Deitrich Gerlt, Ravi Patel, Michael Mogg +3
    The American Journal of Case ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMC
  4. Comparison of feasibility, inter-instrument agreement, and prognostic value of four frailty assessment instruments in geriatric colorectal cancer patients: a 3-year multicenter prospective cohort study
    Lei Ma, Feiyu Shi, Chenhao Hu +4
    Frontiers in oncologyPeer-reviewedCC BYFull textOncologyEurope PMCCrossref
  5. Pan-European Training Program for Robotic Pancreatoduodenectomy (LEARNBOT): Prospective Multicenter Study on Feasibility and Outcome.
    Leia R Jones, Maurice J W Zwart, Felix Nickel +35
    Annals of surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{giaccardi2026prospective,
  title = {{Prospective multicenter feasibility study of omnipolar near-field peak-frequency mapping for slow-pathway localization in typical atrioventricular nodal re-entrant tachycardia.}},
  author = {Marzia Giaccardi and Stella Cartei and Valentina Mangiafico and Maria Lucia Narducci and Roberto Scacciavillani and Marina Zampieri and Maria Luisa Loricchio and Carlos Alberto Centurión Aznaràn and Bruno Albano and Lina Marcantoni and Ambra Del Greco and Giulia Brizzi and Benito Baldauf and Gemma Pelargonio},
  journal = {BMC cardiovascular disorders},
  year = {2026},
  month = oct,
  doi = {10.1186/s12872-026-06779-5},
  url = {https://europepmc.org/article/MED/42926208},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Prospective multicenter feasibility study of omnipolar near-field peak-frequency mapping for slow-pathway localization in typical atrioventricular nodal re-entrant tachycardia.
AU  - Marzia Giaccardi
AU  - Stella Cartei
AU  - Valentina Mangiafico
AU  - Maria Lucia Narducci
AU  - Roberto Scacciavillani
AU  - Marina Zampieri
AU  - Maria Luisa Loricchio
AU  - Carlos Alberto Centurión Aznaràn
AU  - Bruno Albano
AU  - Lina Marcantoni
AU  - Ambra Del Greco
AU  - Giulia Brizzi
AU  - Benito Baldauf
AU  - Gemma Pelargonio
PY  - 2026
DA  - 2026/10/19
JO  - BMC cardiovascular disorders
DO  - 10.1186/s12872-026-06779-5
UR  - https://europepmc.org/article/MED/42926208
AB  - Background  Slow-pathway (SP) ablation is the established therapy for atrioventricular nodal re-entrant tachycardia (AVNRT). While conventional anatomical and electrogram-guided approaches are effective, SP localization may be challenging in a subset of procedures. Omnipolar near-field (OTNF) peak frequency (PF) mapping has been proposed as a signal-based approach to support SP localization; however, prospective multicenter data remain limited.Methods  Fifty consecutive adults with inducible typical AVNRT underwent catheter ablation in three Italian hospitals. High-density right atrial mapping was performed during sinus rhythm using a 16-pole grid catheter (Advisor™ HD Grid) with OTNF on the EnSite X system. PF maps were generated (high-frequency threshold > 250 Hz), and RF applications were delivered to the region of highest PF. Voltage maps were also created to delineate low-voltage bridge (LVB) regions (typically 0.04-2 mV) for retrospective overlap/localization analyses; LVB was not used to select ablation targets.Results  Acute procedural success was achieved in all patients, with no procedural complications. The effective ablation site (junctional beats with subsequent SP modification and/or non-inducibility) corresponded to the highest PF region in 45/50 patients (90%). In a retrospective overlap/localization analysis, the effective site fell within the LVB region in 36/50 patients (72%); concordance between PF-defined and LVB-defined regions at the effective site was observed in 35/50 patients (70%). Mean PF in the SP target region was 424 ± 86 Hz versus 272 ± 57 Hz in surrounding tissue (P < 0.05 on paired testing). Exploratory ROC analysis yielded an AUC of 0.937 with an optimal cutoff of 357 Hz (sensitivity 0.87; specificity 0.94); these estimates should be interpreted cautiously because PF guided RF target selection (incorporation/target-selection bias).Conclusion  In this prospective multicenter cohort, OTNF-derived PF mapping was feasible and reproducibly identified a discrete region used to guide SP ablation in typical AVNRT. ROC-derived thresholds and performance estimates are exploratory and require independent validation in cohorts where ablation targets are not selected using PF criteria.
SN  - 1471-2261
ER  -