Efficacy and safety of low-power (20 W) catheter ablation for typical atrioventricular nodal reentrant tachycardia: a prospective multicenter study
5 affiliations
- 1Division of Cardiology, Jeonbuk National University Hospital and Jeonbuk National University Medical School
- 2Division of Cardiology, Department of Internal Medicine, Konkuk University Medical Center, Konkuk University School of Medicine
- 3Department of Cardiology, Konyang University Hospital
- 4Cardiovascular Center, Seoul National University Bundang Hospital
- 5Department of Cardiology in Internal Medicine, School of Medicine, Chungnam National University, Chungnam National University Sejong Hospital
Abstract
Background: Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common supraventricular tachycardia. Although catheter ablation is the definitive treatment, atrioventricular (AV) block requiring permanent pacemaker implantation remains a major safety concern.
Objective: To evaluate the efficacy and safety of a low-power (20 W) slow pathway ablation strategy for typical AVNRT.
Methods: In this prospective multicenter study, 203 consecutive patients (mean age 54.4 ± 17.3 years; 59.6% women) underwent slow pathway ablation initiated at 20 W, with power escalation as needed. Variables associated with requiring higher power were analyzed using univariable and multivariable logistic regression.
Results: Initial success at 20 W was achieved in 170 patients (83.7%); 33 patients (16.3%) required higher power, with an overall acute success rate of 99.5%. Compared with patients who achieved success at 20 W, those requiring higher power were younger and had higher pre-ablation heart rates. On univariable analysis, younger age [odds ratio [OR] 0.66 per 10-year increase, 95% confidence interval [CI] 0.54–0.83; p < 0.001] and higher pre-ablation heart rate (OR 1.88 per 10-bpm increase, 95% CI 1.30–2.73; p < 0.001) were associated with the need for higher power. Transient AV block occurred in 1.9% of patients, and no cases of permanent AV block (0%, 95% CI 0%–1.8%) or pacemaker implantation were observed. During 18.3 ± 4.1 months of follow-up, recurrence occurred in two patients (0.9%).
Conclusion: An initial 20 W ablation strategy provides high efficacy with a favorable safety profile and no permanent AV block observed in this cohort. Younger age and a higher baseline heart rate predicted the need for power escalation, supporting an initial low-power approach for AVNRT ablation.
Related
- Prospective multicenter feasibility study of omnipolar near-field peak-frequency mapping for slow-pathway localization in typical atrioventricular nodal re-entrant tachycardia.
- Persistence of atrioventricular nodal re-entrant tachycardia during ventricular fibrillation.
- Unveiling Asymptomatic Atrioventricular Reciprocating Tachycardia in a Patient With Wolff-Parkinson-White Syndrome and Multiple Sclerosis
- Clinical efficacy of topical 0.1% tacrolimus in patients with corneal neovascularization: A prospective, multicenter, randomized controlled pilot trial.
- Efficacy and safety of pancrelipase delayed-release capsules (CREON®) from new manufacturing sites: a prospective, multicenter, randomized, double-blind, active-controlled, two-part, two-period, two-sequence, crossover, non-inferiority study
BibTeX
@article{jung2026efficacy,
title = {{Efficacy and safety of low-power (20 W) catheter ablation for typical atrioventricular nodal reentrant tachycardia: a prospective multicenter study}},
author = {Lae-Young Jung and Chang Hee Kwon and In Geol Song and Ji Hyun Lee and Minsu Kim},
journal = {Frontiers in Cardiovascular Medicine},
year = {2026},
month = oct,
doi = {10.3389/fcvm.2026.1949109},
url = {https://www.frontiersin.org/articles/10.3389/fcvm.2026.1949109/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Efficacy and safety of low-power (20 W) catheter ablation for typical atrioventricular nodal reentrant tachycardia: a prospective multicenter study
AU - Lae-Young Jung
AU - Chang Hee Kwon
AU - In Geol Song
AU - Ji Hyun Lee
AU - Minsu Kim
PY - 2026
DA - 2026/10/30
JO - Frontiers in Cardiovascular Medicine
DO - 10.3389/fcvm.2026.1949109
UR - https://www.frontiersin.org/articles/10.3389/fcvm.2026.1949109/full
AB - Background: Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common supraventricular tachycardia. Although catheter ablation is the definitive treatment, atrioventricular (AV) block requiring permanent pacemaker implantation remains a major safety concern. Objective: To evaluate the efficacy and safety of a low-power (20 W) slow pathway ablation strategy for typical AVNRT. Methods: In this prospective multicenter study, 203 consecutive patients (mean age 54.4 ± 17.3 years; 59.6% women) underwent slow pathway ablation initiated at 20 W, with power escalation as needed. Variables associated with requiring higher power were analyzed using univariable and multivariable logistic regression. Results: Initial success at 20 W was achieved in 170 patients (83.7%); 33 patients (16.3%) required higher power, with an overall acute success rate of 99.5%. Compared with patients who achieved success at 20 W, those requiring higher power were younger and had higher pre-ablation heart rates. On univariable analysis, younger age [odds ratio [OR] 0.66 per 10-year increase, 95% confidence interval [CI] 0.54–0.83; p < 0.001] and higher pre-ablation heart rate (OR 1.88 per 10-bpm increase, 95% CI 1.30–2.73; p < 0.001) were associated with the need for higher power. Transient AV block occurred in 1.9% of patients, and no cases of permanent AV block (0%, 95% CI 0%–1.8%) or pacemaker implantation were observed. During 18.3 ± 4.1 months of follow-up, recurrence occurred in two patients (0.9%). Conclusion: An initial 20 W ablation strategy provides high efficacy with a favorable safety profile and no permanent AV block observed in this cohort. Younger age and a higher baseline heart rate predicted the need for power escalation, supporting an initial low-power approach for AVNRT ablation.
SN - 2297-055X
ER -