Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 30 min ago
Peer-reviewedCC BY 4.0North American Spine Society Journal

Evaluation of a pre-set calcium sulphate dihydrate/hydroxyapatite bone graft extender in a rabbit posterolateral spinal fusion model

1 more authors
6 affiliations
  1. 1The Faculty of Medicine, Department of Clinical Sciences Lund, Orthopedics, Lund University, Lund, Sweden
  2. 2Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania
  3. 3Department of Neurosurgery, Spinal Neurosurgery Unit, Lithuanian University of Health Sciences, Kaunas, Lithuania
  4. 4Faculty of Medicine, Lithuanian University of Health Sciences, Kaunas, Lithuania
  5. 5Department of Orthopedic Surgery, University of Copenhagen, Rigshospitalet, Copenhagen, Denmark
  6. 6Department of Orthopedics, Trauma Surgery and Rehabilitation Medicine, Greifswald University Hospital, Greifswald, Germany

Abstract

Background: Ceramic biomaterials are increasingly used as bone graft extenders (BGE) in spinal fusion surgery. The aim of this study was to evaluate the efficacy of a novel pre-set calcium sulphate/hydroxyapatite biomaterial (XERAFUSE) beads as a BGE using a well-established rabbit posterolateral lumbar spinal fusion model (PLF).

Methods: Twenty-six skeletally mature rabbits underwent L4–L5 PLF using 2 treatment strategies: 1. Autograft alone (ABG) or 2. XERAFUSE co-implanted with ABG in 1:1 volume ratio (XER + ABG). Evaluation of spinal fusion was performed post-mortem at 4-, 8-, and 12-weeks for XER + ABG group and at 12-weeks for the ABG group. Evaluation of spinal fusion was performed using radiography, micro–computed tomography (micro-CT), manual palpation and histological analysis.

Results: Based on the micro-CT based histomorphometric analysis, the fusion mass in XER + ABG group demonstrated an increase in bone volume (59%–72%) and reduction in material volume (41% vs 28%) between the 4- and the 12-week time points. The bone volume in the XER + ABG group (850 ± 68.4 mm³) was significantly higher than in the autograft comparator group (468.9 ± 105.3 mm³) at 12-weeks. The outcome from qualitative analysis at 12-weeks using planar radiography, 2D and 3D micro-CT imaging, manual palpation and histology demonstrated 86% healing in XER + ABG group while 57% specimens demonstrated healing in the ABG group.

Conclusions: The results from our study indicate that XERAFUSE is a safe and efficient BGE, demonstrating significantly greater bone volume than autograft control, and fusion rates consistent with the model. The use of XERAFUSE as a BGE may reduce dependence on large volumes of autologous bone graft in spinal fusion surgery while maintaining or improving fusion performance. These findings support the translational potential of calcium sulphate/hydroxyapatite composite biomaterials as clinically relevant BGE in spinal arthrodesis procedures.

Related

  1. Calcium sulphate dihydrate isolated from terra flava usta alleviates ulcerative colitis in mice via PI3K-akt signaling pathway and gut microbiota
    Zhenwu Wang, Shuang Liu, Hongjing Dong +4
    Frontiers in PharmacologyPeer-reviewedCC BY 4.0Full textPharmacology & toxicologyFrontiersCrossrefDOAJ
  2. Biomechanical evaluation of the gravity varus test in a cadaveric model of posterolateral rotatory instability of the elbow.
    Jordan A Bauer, Rohan Rajan, Rajendra Singh +6
    JSES internationalPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. Intra-articular Extender Button Deployment Without a Secondary Incision for Salvage of Compromised Femoral Cortical Fixation in Anterior Cruciate Ligament Reconstruction.
    Priya Singh, Brandon Boyd, D'Arcy Marsh +1
    Arthroscopy techniquesPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCPMC
  4. Comparison of Modified Lake’s Extender for Cryopreservation of Hungarian Giant and Chrabrany Rabbit Sperm
    Éva Kissné Váradi, Jakub Vozaf, Jaromír Vašíček +8
    Animals : an Open Access Journal from MDPIPeer-reviewedCC BY 4.0Full textObstetrics, gynaecology & paediatricsPMC
  5. Clinical Outcomes and Safety Associated with Adjunctive Antibiotic-Loaded Calcium Sulphate Beads in Hip and Knee Periprosthetic Joint Infection: A Systematic Review
    Abdulelah K. Alqawlaq, Ruwaydah Hamoud M. Alruways, Wesal Abdulrahman Alqurashi +7
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{lukoseviciutė2026evaluation,
  title = {{Evaluation of a pre-set calcium sulphate dihydrate/hydroxyapatite bone graft extender in a rabbit posterolateral spinal fusion model}},
  author = {Gintarė Lukoševičiūtė and Filip Mrkonjic and Jintian Huang and Hadis Alidadi and Domantas Jakstas and Paulius Zasčiurinskas and Šarūnas Tarasevičius and Alfredas Smailys and Benny Dahl and Stefan Zwingenberger and Lars Lidgren and Magnus Tägil and Deepak Bushan Raina},
  journal = {North American Spine Society Journal},
  year = {2026},
  month = oct,
  doi = {10.1016/j.xnsj.2026.100955},
  url = {https://doi.org/10.1016/j.xnsj.2026.100955},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Evaluation of a pre-set calcium sulphate dihydrate/hydroxyapatite bone graft extender in a rabbit posterolateral spinal fusion model
AU  - Gintarė Lukoševičiūtė
AU  - Filip Mrkonjic
AU  - Jintian Huang
AU  - Hadis Alidadi
AU  - Domantas Jakstas
AU  - Paulius Zasčiurinskas
AU  - Šarūnas Tarasevičius
AU  - Alfredas Smailys
AU  - Benny Dahl
AU  - Stefan Zwingenberger
AU  - Lars Lidgren
AU  - Magnus Tägil
AU  - Deepak Bushan Raina
PY  - 2026
DA  - 2026/10/06
JO  - North American Spine Society Journal
DO  - 10.1016/j.xnsj.2026.100955
UR  - https://doi.org/10.1016/j.xnsj.2026.100955
AB  - Background: Ceramic biomaterials are increasingly used as bone graft extenders (BGE) in spinal fusion surgery. The aim of this study was to evaluate the efficacy of a novel pre-set calcium sulphate/hydroxyapatite biomaterial (XERAFUSE) beads as a BGE using a well-established rabbit posterolateral lumbar spinal fusion model (PLF).  Methods: Twenty-six skeletally mature rabbits underwent L4–L5 PLF using 2 treatment strategies: 1. Autograft alone (ABG) or 2. XERAFUSE co-implanted with ABG in 1:1 volume ratio (XER + ABG). Evaluation of spinal fusion was performed post-mortem at 4-, 8-, and 12-weeks for XER + ABG group and at 12-weeks for the ABG group. Evaluation of spinal fusion was performed using radiography, micro–computed tomography (micro-CT), manual palpation and histological analysis.  Results: Based on the micro-CT based histomorphometric analysis, the fusion mass in XER + ABG group demonstrated an increase in bone volume (59%–72%) and reduction in material volume (41% vs 28%) between the 4- and the 12-week time points. The bone volume in the XER + ABG group (850 ± 68.4 mm³) was significantly higher than in the autograft comparator group (468.9 ± 105.3 mm³) at 12-weeks. The outcome from qualitative analysis at 12-weeks using planar radiography, 2D and 3D micro-CT imaging, manual palpation and histology demonstrated 86% healing in XER + ABG group while 57% specimens demonstrated healing in the ABG group.  Conclusions: The results from our study indicate that XERAFUSE is a safe and efficient BGE, demonstrating significantly greater bone volume than autograft control, and fusion rates consistent with the model. The use of XERAFUSE as a BGE may reduce dependence on large volumes of autologous bone graft in spinal fusion surgery while maintaining or improving fusion performance. These findings support the translational potential of calcium sulphate/hydroxyapatite composite biomaterials as clinically relevant BGE in spinal arthrodesis procedures.
SN  - 2666-5484
ER  -