Prognostic Impact of Overhydration in Hospitalized Patients Receiving Parenteral Nutrition
- 1Nutrition Support Unit, Endocrinology and Nutrition Department, Hospital Universitari Vall d’Hebron, 08035 Barcelona, Spain
- 2ISS IR-HUVH-VHIR Diabetes and Metabolism Research Group, Endocrinology Department, Vall d’Hebron University Hospital, Autonomous University of Barcelona, 08035 Barcelona, Spain
- 3Department of Pharmacology, Autonomous University of Barcelona, 08193 Bellaterra, Cerdanyola del Vallès, Barcelona, Spain
Abstract
Background & Aims: Accurate assessment of hydration status is particularly relevant in hospitalized patients receiving parenteral support in whom fluid disturbances are common and may be associated with adverse outcomes. However, the prognostic significance of bioimpedance-derived hydration status in the population receiving parenteral nutrition (PN) remains poorly defined. This study aimed to evaluate the association between hydration status at the beginning of PN and in-hospital mortality. Methods: This single-center prospective observational cohort included hospitalized adults receiving PN between November 2024 and March 2026. Hydration status was assessed within 72 h of PN initiation using bioelectrical impedance analysis (Hydragram®, Akern). Receiver operating characteristic (ROC) analysis was used to identify the optimal hydration threshold for in-hospital mortality prediction. Survival was evaluated using Kaplan–Meier analysis and Cox proportional hazards models. Results: A total of 276 patients were included (62.0% male; mean age 64.9 ± 17.5 years). Overall in-hospital mortality was 13.4%. Hydration percentage showed good discrimination for in-hospital mortality (AUC 0.776, 95% CI 0.672–0.880; p < 0.001), with an optimal cut-off value of 79.45%. Patients with overhydration exhibited higher mortality rates than normohydrated patients (29.3% vs. 5.4%; log-rank p < 0.001). In multivariable Cox regression analysis, overhydration remained independently associated with in-hospital mortality (HR 2.85, 95% CI 1.21–6.70; p = 0.016), together with age (HR 1.06, 95% CI 1.02–1.10; p = 0.002). Bioelectrical impedance vector analysis (BIVA) demonstrated a clustering of non-survivors in vector regions consistent with extracellular fluid expansion. Conclusions: Overhydration assessed by bioelectrical impedance analysis was independently associated with in-hospital mortality in patients receiving PN. Early assessment of hydration status by bioelectrical impedance may provide clinically relevant information for risk stratification in hospitalized patients receiving parenteral nutrition.
Related
- Vitamins E and C supplementation reduces hepatic lipid peroxidation and steatosis in neonatal Yucatan piglets receiving prolonged parenteral nutrition
- Stepwise administration of de novo ketogenic parenteral nutrition for refractory epilepsy during prolonged bowel rest following duodenal perforation
- Manganese Deposition Encephalopathy Associated With Prolonged Total Parenteral Nutrition: A Case Report
- Parenteral Nutrition as a Source of Xenobiotic Exposure in Preterm Infants in a Single-Center Case Study
- Parenteral Nutrition as a Strategic Therapeutic Option for Onco-Geriatric Rehabilitation After Total Gastrectomy and Anastomotic Stenosis Complicated by an Aorto-Esophageal Fistula: A Case Report.
BibTeX
@article{zabaleguieguinoa2026prognostic,
title = {{Prognostic Impact of Overhydration in Hospitalized Patients Receiving Parenteral Nutrition}},
author = {Alba Zabalegui-Eguinoa and Fernanda Mucarzel-Suarez-Arana and Raül Cartiel-Vesperinas and Cora Oliver-Vila and Marta Ricart-Viles and Laura Andurell-Ferrandiz and Amador Lluch-Romero and Albert Puig-Perez and Fiorella Palmas and Rosa Burgos-Peláez},
journal = {Nutrients},
year = {2026},
month = oct,
doi = {10.3390/nu18213528},
url = {https://www.mdpi.com/2072-6643/18/21/3528},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Prognostic Impact of Overhydration in Hospitalized Patients Receiving Parenteral Nutrition
AU - Alba Zabalegui-Eguinoa
AU - Fernanda Mucarzel-Suarez-Arana
AU - Raül Cartiel-Vesperinas
AU - Cora Oliver-Vila
AU - Marta Ricart-Viles
AU - Laura Andurell-Ferrandiz
AU - Amador Lluch-Romero
AU - Albert Puig-Perez
AU - Fiorella Palmas
AU - Rosa Burgos-Peláez
PY - 2026
DA - 2026/10/26
JO - Nutrients
DO - 10.3390/nu18213528
UR - https://www.mdpi.com/2072-6643/18/21/3528
AB - Background & Aims: Accurate assessment of hydration status is particularly relevant in hospitalized patients receiving parenteral support in whom fluid disturbances are common and may be associated with adverse outcomes. However, the prognostic significance of bioimpedance-derived hydration status in the population receiving parenteral nutrition (PN) remains poorly defined. This study aimed to evaluate the association between hydration status at the beginning of PN and in-hospital mortality. Methods: This single-center prospective observational cohort included hospitalized adults receiving PN between November 2024 and March 2026. Hydration status was assessed within 72 h of PN initiation using bioelectrical impedance analysis (Hydragram®, Akern). Receiver operating characteristic (ROC) analysis was used to identify the optimal hydration threshold for in-hospital mortality prediction. Survival was evaluated using Kaplan–Meier analysis and Cox proportional hazards models. Results: A total of 276 patients were included (62.0% male; mean age 64.9 ± 17.5 years). Overall in-hospital mortality was 13.4%. Hydration percentage showed good discrimination for in-hospital mortality (AUC 0.776, 95% CI 0.672–0.880; p < 0.001), with an optimal cut-off value of 79.45%. Patients with overhydration exhibited higher mortality rates than normohydrated patients (29.3% vs. 5.4%; log-rank p < 0.001). In multivariable Cox regression analysis, overhydration remained independently associated with in-hospital mortality (HR 2.85, 95% CI 1.21–6.70; p = 0.016), together with age (HR 1.06, 95% CI 1.02–1.10; p = 0.002). Bioelectrical impedance vector analysis (BIVA) demonstrated a clustering of non-survivors in vector regions consistent with extracellular fluid expansion. Conclusions: Overhydration assessed by bioelectrical impedance analysis was independently associated with in-hospital mortality in patients receiving PN. Early assessment of hydration status by bioelectrical impedance may provide clinically relevant information for risk stratification in hospitalized patients receiving parenteral nutrition.
SN - 2072-6643
ER -