Prehospital Ultrasound to Identify Endotracheal Tube Dislodgment in an Infant: A Case Report
- 1Edward Via College of Osteopathic Medicine, Blacksburg, Virginia
- 2Christiansburg Emergency Medical Services, Christiansburg, Virginia
Abstract
Introduction: Point-of-care ultrasound (POCUS) is well established as a useful adjunct for airway management in both adult and pediatric patients, including confirmation of successful endotracheal intubation. While suprasternal ultrasound of the trachea is the most described method for confirming endotracheal tube (ETT) placement, a focused lung exam can be used to rapidly identify appropriate ventilation in otherwise apneic patients. Case Report: This case involves a one-month-old male infant who experienced an out-of-hospital cardiac arrest secondary to suspected sudden infant death syndrome. During resuscitation, an accidental extubation occurred after an attempt at securing the ETT with a commercial pediatric tube holder. Loss of end-tidal carbon dioxide (ETCO 2) waveform was recognized immediately; however, emergency medical services clinicians questioned the device’s accuracy due to earlier failures of the ETCO 2 monitor and the ETT remaining secured at an expected depth. A rapid POCUS lung examination demonstrated absence of bilateral lung sliding. The patient was immediately extubated, revealing a kinked ETT in the oropharynx with the distal tip positioned above the vocal cords. A supraglottic airway device (SGA) was placed with a successful return of ETCO 2 waveform, followed shortly by successful reintubation because of difficulty ventilating through the SGA. Conclusion: Lung ultrasound is a rapid and effective alternative for identifying ETT dislodgment when conventional verification methods are unreliable or unavailable. As ultrasound becomes increasingly available in prehospital and resource-limited settings, it may be effectively used by nonphysician clinicians to confirm airway placement and detect airway complications.
Related
- Prehospital endotracheal intubation and return of spontaneous circulation in out-of-hospital cardiac arrest patients: a retrospective cohort study based on prehospital emergency registry data
- Airway ultrasound versus capnography to confirm endotracheal intubation: protocol for a systematic review and meta-analysis
- Added value of brain perfusion ultrasound to prehospital stroke scales-a secondary analysis of the SONAS trial
- Multihipposenet: multi-task deep learning for automated DDH assessment in infant hip ultrasound
- AI-Assisted Sequential Graf Assessment of Infant Hip Ultrasound: A Retrospective Single-Centre Evaluation in a Referral Cohort.
BibTeX
@article{wright2026prehospital,
title = {{Prehospital Ultrasound to Identify Endotracheal Tube Dislodgment in an Infant: A Case Report}},
author = {Nicholas A. Wright and Ryan Lucas and Peyton Bailey},
journal = {Clinical Practice and Cases in Emergency Medicine},
year = {2026},
month = sep,
doi = {10.5811/cpcem.63870},
url = {https://doi.org/10.5811/cpcem.63870},
note = {CC BY},
}
RIS
TY - JOUR
TI - Prehospital Ultrasound to Identify Endotracheal Tube Dislodgment in an Infant: A Case Report
AU - Nicholas A. Wright
AU - Ryan Lucas
AU - Peyton Bailey
PY - 2026
DA - 2026/09/01
JO - Clinical Practice and Cases in Emergency Medicine
DO - 10.5811/cpcem.63870
UR - https://doi.org/10.5811/cpcem.63870
AB - Introduction: Point-of-care ultrasound (POCUS) is well established as a useful adjunct for airway management in both adult and pediatric patients, including confirmation of successful endotracheal intubation. While suprasternal ultrasound of the trachea is the most described method for confirming endotracheal tube (ETT) placement, a focused lung exam can be used to rapidly identify appropriate ventilation in otherwise apneic patients. Case Report: This case involves a one-month-old male infant who experienced an out-of-hospital cardiac arrest secondary to suspected sudden infant death syndrome. During resuscitation, an accidental extubation occurred after an attempt at securing the ETT with a commercial pediatric tube holder. Loss of end-tidal carbon dioxide (ETCO 2) waveform was recognized immediately; however, emergency medical services clinicians questioned the device’s accuracy due to earlier failures of the ETCO 2 monitor and the ETT remaining secured at an expected depth. A rapid POCUS lung examination demonstrated absence of bilateral lung sliding. The patient was immediately extubated, revealing a kinked ETT in the oropharynx with the distal tip positioned above the vocal cords. A supraglottic airway device (SGA) was placed with a successful return of ETCO 2 waveform, followed shortly by successful reintubation because of difficulty ventilating through the SGA. Conclusion: Lung ultrasound is a rapid and effective alternative for identifying ETT dislodgment when conventional verification methods are unreliable or unavailable. As ultrasound becomes increasingly available in prehospital and resource-limited settings, it may be effectively used by nonphysician clinicians to confirm airway placement and detect airway complications.
SN - 2474-252X
ER -