Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BYJournal of imaging

AI-Assisted Sequential Graf Assessment of Infant Hip Ultrasound: A Retrospective Single-Centre Evaluation in a Referral Cohort.

6 affiliations
  1. 1Pediatric Orthopaedics and Trauma, Regina Margherita Children's Hospital, 10126 Turin, Italy.
  2. 2Department of Surgical Sciences, University of Turin, 10126 Turin, Italy.
  3. 3School of Medicine, University of Turin, 10126 Turin, Italy.
  4. 4Department of Management and Production Engineering, Politecnico di Torino, 10129 Turin, Italy.
  5. 5Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Turin, Italy.
  6. 6Pediatric Radiology, Regina Margherita Children's Hospital, 10126 Turin, Italy.

Abstract

Graf-method ultrasound supports early assessment of developmental dysplasia of the hip (DDH). This study assessed a sequential artificial-intelligence-assisted workflow and clinicians' Checklist I decisions with and without computer-aided diagnosis (CAD). This retrospective single-centre study of referred infants used 1803 development images from 679 examinations and separate cohorts of 1024 workflow and 100 reader images; Graf IV hips were excluded. ResTransUNet segmented eight Checklist I structures to assess reportability. Fifteen clinicians assessed the reader images unaided and four weeks later with CAD. Stand-alone Checklist I accuracy was 93.0% (93/100; 95% CI 86.3-96.6). Of 1024 workflow images, 846 received final outputs; Checklist II non-compliance precision was 48.1%. Among accepted images, the non-type-I endpoint had 81.0% accuracy, 82.7% sensitivity and 80.4% specificity; exact Graf-type agreement was 40.1%. Across entering non-type-I images, 167/266 (62.8%) received a correct positive output. Mean absolute errors were 3.59° for the α angle and 11.91° for the β angle, with a β-angle bias of +11.07°. Clinician accuracy was 72.3% unaided and 90.2% assisted-an observed 17.9 percentage-point difference (95% CI 10.0-26.1); 26 correct decisions became incorrect on AI-error cases. The workflow supported Checklist I assessment, but fixed order precludes causal CAD inference; gate failures and angle errors require refinement and prospective evaluation before clinical implementation.

Related

  1. Efficacy and Safety of a Single Session of Micro‐Focused Ultrasound for Mid‐To‐Lower Facial Rejuvenation: A Retrospective Multimodal Assessment Study Using Clinical Evaluation, High‐Frequency Ultrasound, and VISIA Skin Analysis
    Yuanyuan Qu, Fang Xiang, Jiawen Ma +3
    Journal of Cosmetic DermatologyPeer-reviewedCC BY 4.0Full textGeneral medicinePMCEurope PMC
  2. Pilot Evaluation of Patient-Assisted Motorized Transvaginal Ultrasound Acquisition During Ovarian Stimulation Monitoring
    T. Shavit, P. Bortoletto, J. Szychter +4
    medRxivPreprintAll rights reservedFull textObstetrics, gynaecology & paediatricsmedRxiv
  3. Evaluation and performance of the β-hCG discriminatory zone and targeted ultrasound findings for early pregnancy diagnosis in a high-risk population: a retrospective cohort study at a US safety-net hospital.
    Panagiotis Cherouveim, Shagun Tuli, Esra Cetin +7
    BMJ openPeer-reviewedCC BY-NCFull textEpidemiology & public healthEurope PMCCrossref
  4. Contrast-enhanced ultrasound-assisted catheter drainage for paravertebral tuberculous abscesses: a retrospective study of procedural safety
    Dan Li, Peijun Chen, Wenzhi Zhang
    Frontiers in medicinePeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
  5. Ultrasound-Assisted Deep Eutectic Solvent Extraction of Flavonoids from Hovenia dulcis Thunb: Optimization, Phytochemical Profiling, and Antioxidant and Anti-Inflammatory Activity Evaluation.
    Lei Zhou, Haixin Li, Xu Zhou +2
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{audisio2026aiassisted,
  title = {{AI-Assisted Sequential Graf Assessment of Infant Hip Ultrasound: A Retrospective Single-Centre Evaluation in a Referral Cohort.}},
  author = {Andrea Audisio and Alessandro Aprato and Jessica Hu and Giorgia Marullo and Matteo Sabbatini and Luca Ulrich and Sandro Moos and Marco Petraz and Enrico Vezzetti and Alessandro Massè},
  journal = {Journal of imaging},
  year = {2026},
  month = nov,
  doi = {10.3390/jimaging12110554},
  url = {https://europepmc.org/article/MED/43082944},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - AI-Assisted Sequential Graf Assessment of Infant Hip Ultrasound: A Retrospective Single-Centre Evaluation in a Referral Cohort.
AU  - Andrea Audisio
AU  - Alessandro Aprato
AU  - Jessica Hu
AU  - Giorgia Marullo
AU  - Matteo Sabbatini
AU  - Luca Ulrich
AU  - Sandro Moos
AU  - Marco Petraz
AU  - Enrico Vezzetti
AU  - Alessandro Massè
PY  - 2026
DA  - 2026/11/05
JO  - Journal of imaging
DO  - 10.3390/jimaging12110554
UR  - https://europepmc.org/article/MED/43082944
AB  - Graf-method ultrasound supports early assessment of developmental dysplasia of the hip (DDH). This study assessed a sequential artificial-intelligence-assisted workflow and clinicians' Checklist I decisions with and without computer-aided diagnosis (CAD). This retrospective single-centre study of referred infants used 1803 development images from 679 examinations and separate cohorts of 1024 workflow and 100 reader images; Graf IV hips were excluded. ResTransUNet segmented eight Checklist I structures to assess reportability. Fifteen clinicians assessed the reader images unaided and four weeks later with CAD. Stand-alone Checklist I accuracy was 93.0% (93/100; 95% CI 86.3-96.6). Of 1024 workflow images, 846 received final outputs; Checklist II non-compliance precision was 48.1%. Among accepted images, the non-type-I endpoint had 81.0% accuracy, 82.7% sensitivity and 80.4% specificity; exact Graf-type agreement was 40.1%. Across entering non-type-I images, 167/266 (62.8%) received a correct positive output. Mean absolute errors were 3.59° for the α angle and 11.91° for the β angle, with a β-angle bias of +11.07°. Clinician accuracy was 72.3% unaided and 90.2% assisted-an observed 17.9 percentage-point difference (95% CI 10.0-26.1); 26 correct decisions became incorrect on AI-error cases. The workflow supported Checklist I assessment, but fixed order precludes causal CAD inference; gate failures and angle errors require refinement and prospective evaluation before clinical implementation.
SN  - 2313-433X
ER  -