A Simplified LC-MS/MS Method for the Determination of Anticoagulant Rodenticides in Emergency Department Patients with Unexplained Coagulopathy.
10 affiliations
- 1Department of Medical Toxicology, Taichung Veterans General Hospital, Taichung 407219, Taiwan.
- 2SCIEX, Taipei 114063, Taiwan.
- 3Department of Nursing, Taipei Veterans General Hospital, Taipei 112201, Taiwan.
- 4Department of Medical Laboratory Science and Biotechnology, Central Taiwan University of Science and Technology, Taichung 406053, Taiwan.
- 5Department of Applied Chemistry, Chaoyang University of Technology, Taichung 413310, Taiwan.
- 6Division of Infectious Diseases, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung 407219, Taiwan.
- 7Rong Hsing Research Center for Translational Medicine, National Chung Hsing University, Taichung 402202, Taiwan.
- 8Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung 402202, Taiwan.
- 9PhD Program in Medical Biotechnology, College of Medical Science and Technology, Taipei Medical University, Taipei 235603, Taiwan.
- 10College of Medicine, National Defense Medical University, Taipei 114201, Taiwan.
Abstract
Anticoagulant rodenticide (AR) poisoning may cause prolonged and potentially life-threatening coagulopathy, while confirmation of exposure can be challenging when the exposure history is unclear. We developed and validated a simplified liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of five ARs and warfarin in human plasma and evaluated its clinical applicability in a patient with unexplained coagulopathy. The method used 50 μL of plasma with a simple protein-precipitation procedure followed by LC-MS/MS analysis. The validated quantitative range was 10-1000 ng/mL, with a lower limit of quantification of 10 ng/mL, while all analytes fulfilled the predefined qualitative identification criteria at 5 ng/mL. The method demonstrated acceptable accuracy, precision, selectivity, and matrix-effect performance. In the clinical case, bromadiolone was identified, and two plasma measurements showed a declining concentration profile, with an estimated apparent elimination half-life of 10.4 days. Based on this estimate, the plasma bromadiolone concentration was predicted to decline below 10 ng/mL at approximately day 42. This estimated concentration trajectory, together with the patient's clinical course and serial coagulation findings, supported the decision to discontinue oral vitamin K1 on day 42. Subsequent INR measurements remained normal on days 45 and 49. Although 10 ng/mL served as a practical reference in this case, it should not be used as the sole criterion for vitamin K1 discontinuation. This simplified LC-MS/MS method provides a practical approach for identifying and quantifying AR exposure in patients with otherwise unexplained coagulopathy and may support clinical assessment and management.
Related
- Platelet trajectory subphenotypes in intensive care patients with sepsis-induced coagulopathy
- Challenges of turning prehospital prediction of trauma-induced coagulopathy into early administration of tranexamic acid.
- Unexpected coagulopathy in thrombolyzed stroke: experience from a single center in Chile
- SFTSV infection drives platelet-associated fibrinogen accumulation and platelet-mediated coagulopathy
- Platelet activation and coronavirus disease 2019 mortality: Insights from coagulopathy, antiplatelet therapy and inflammation
BibTeX
@article{liao2026simplified,
title = {{A Simplified LC-MS/MS Method for the Determination of Anticoagulant Rodenticides in Emergency Department Patients with Unexplained Coagulopathy.}},
author = {Hsiao-Chia Liao and Shu-Mei Chi and Kuan-Ling Chen and Jyun-Han Lin and Su-Chin Chen and Yu-Cheng Li and Szu-Yin Hsieh and Shih-Rong Lin and Sin-Tong Lan and Kai-Ju Lee and Hsuan-Wei Huang and Hung-Yu Lin and Po-Yu Liu and Jun-Jen Liu and Yan-Chiao Mao},
journal = {Journal of xenobiotics},
year = {2026},
month = oct,
doi = {10.3390/jox16070203},
url = {https://europepmc.org/article/MED/43083258},
note = {CC BY},
}
RIS
TY - JOUR
TI - A Simplified LC-MS/MS Method for the Determination of Anticoagulant Rodenticides in Emergency Department Patients with Unexplained Coagulopathy.
AU - Hsiao-Chia Liao
AU - Shu-Mei Chi
AU - Kuan-Ling Chen
AU - Jyun-Han Lin
AU - Su-Chin Chen
AU - Yu-Cheng Li
AU - Szu-Yin Hsieh
AU - Shih-Rong Lin
AU - Sin-Tong Lan
AU - Kai-Ju Lee
AU - Hsuan-Wei Huang
AU - Hung-Yu Lin
AU - Po-Yu Liu
AU - Jun-Jen Liu
AU - Yan-Chiao Mao
PY - 2026
DA - 2026/10/22
JO - Journal of xenobiotics
DO - 10.3390/jox16070203
UR - https://europepmc.org/article/MED/43083258
AB - Anticoagulant rodenticide (AR) poisoning may cause prolonged and potentially life-threatening coagulopathy, while confirmation of exposure can be challenging when the exposure history is unclear. We developed and validated a simplified liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of five ARs and warfarin in human plasma and evaluated its clinical applicability in a patient with unexplained coagulopathy. The method used 50 μL of plasma with a simple protein-precipitation procedure followed by LC-MS/MS analysis. The validated quantitative range was 10-1000 ng/mL, with a lower limit of quantification of 10 ng/mL, while all analytes fulfilled the predefined qualitative identification criteria at 5 ng/mL. The method demonstrated acceptable accuracy, precision, selectivity, and matrix-effect performance. In the clinical case, bromadiolone was identified, and two plasma measurements showed a declining concentration profile, with an estimated apparent elimination half-life of 10.4 days. Based on this estimate, the plasma bromadiolone concentration was predicted to decline below 10 ng/mL at approximately day 42. This estimated concentration trajectory, together with the patient's clinical course and serial coagulation findings, supported the decision to discontinue oral vitamin K1 on day 42. Subsequent INR measurements remained normal on days 45 and 49. Although 10 ng/mL served as a practical reference in this case, it should not be used as the sole criterion for vitamin K1 discontinuation. This simplified LC-MS/MS method provides a practical approach for identifying and quantifying AR exposure in patients with otherwise unexplained coagulopathy and may support clinical assessment and management.
SN - 2039-4705
SN - 2039-4713
ER -