Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 35 min ago
Peer-reviewedCC BY 4.0PLOS One

Persistent residual ellipticity in waveplate-compensated polarization-resolved SHG microscopy on a commercial multiphoton microscope

4 affiliations
  1. 1Scientific Center for Optical and Electron Microscopy (ScopeM), ETH Zürich, Zürich, Switzerland
  2. 2Department of Electrical Engineering, Stanford University, Stanford, California, United States of America
  3. 3Department of Molecular Life Sciences, University of Zürich, Zürich, Switzerland
  4. 4Laboratory for High Performance Ceramics, Empa Dübendorf, Dübendorf, Switzerland

Abstract

Polarization-resolved second harmonic generation microscopy provides structural information about non-centrosymmetric biological samples such as collagen. It involves illuminating the sample with a focused laser beam having a variable linear polarization angle and recording the second harmonic signal as a function of this angle. However, accurate linear polarization control is challenging due to ellipticity introduced by reflections from mirrors and dichroic mirrors in the optical path. Waveplate-based compensation has emerged as the standard approach to address these distortions, but its effectiveness for quantitative measurements remains incompletely characterized. Here, we reproduce an established automated waveplate compensation method, based on a rotating half-waveplate combined with a compensating quarter-waveplate, on a commercial Leica TCS SP8 MP multiphoton microscope, which is the same type of instrument the method was originally developed on. Despite significant effort, we consistently observed substantial unwanted residual polarization ellipticity, with amplitudes up to 0.24, persisting under optimal waveplate configurations. Our simulation analysis suggests that this limitation may arise from wavelength-dependent dichroic mirror birefringence combined with the broad spectral bandwidth (10 nm to 20 nm full width at half maximum) of femtosecond laser pulses. While the approach investigated here can compensate a single wavelength, different spectral components within the pulse experience different phase retardations from wavelength-dependent optical elements, potentially resulting in residual ellipticity that cannot be eliminated. Our simulations qualitatively reproduced key features of the experimental observations. These findings have important implications for quantitative polarization-resolved second harmonic generation microscopy and suggest that alternative approaches, including specimen rotation or picosecond laser sources with narrower bandwidth, should be investigated for applications requiring precise polarization control. To facilitate community investigation of these effects, we provide open-source analysis code and simulation files.

Related

  1. Single-Shot Polarization Imaging of Vectorial Metasurfaces Using Cross-Grating Wavefront Microscopy
    Julien Flamant, Baptiste Marthy, Khosro Zangeneh Kamali +5
    ACS NanoPeer-reviewedCC BY-NC-ND 4.0Full textMaterials & polymersHALPMC
  2. Compensated Grid-Based Hybrid Exchange - A Simple, Accurate, Efficient, and Differentiable Recipe for Large-Scale Molecular Systems
    Edward G. Hohenstein, Melisa Alkan, Xiaojie Wu +1
    arXivPreprintarXiv licenceFull textPhysical chemistryarXiv
  3. A high-sensitivity resistance bridge for nanoscale thermal microscopy
    Wilfrid Poirier, Victor Guillemot, Mohammed Mghalfi +2
    HALPreprintLicence not statedFull textMaterials & polymersHAL
  4. Investigation of Secondary Phase Evolution in LSCF Electrodes during Long-Term SOEC Operation by X‑ray Diffraction and Electron Microscopy Characterizations
    ACS omegaPeer-reviewedCC BY-NC-NDFull textGeneral chemistryEurope PMC
  5. Aryldiazonium reduction mechanism deciphered by scanning electrochemical microscopy through an EC’ process
    Nikolaos Kostopoulos, Viacheslav Shkirskiy, Catherine Combellas +3
    Electrochimica ActaPeer-reviewedLicence not stated1 citedElectrochemistry & energyHAL
BibTeX
@article{nguyen2026persistent,
  title = {{Persistent residual ellipticity in waveplate-compensated polarization-resolved SHG microscopy on a commercial multiphoton microscope}},
  author = {David Nguyen and Jeffrey P. Wilde and Virginie Uhlmann and Daniel James Smith and Justine Kusch-Wieser and Valeria Zanrè and Jakob Schwiedrzik and Gábor Csúcs},
  journal = {PLOS One},
  year = {2026},
  month = nov,
  doi = {10.1371/journal.pone.0357256},
  url = {https://doi.org/10.1371/journal.pone.0357256},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Persistent residual ellipticity in waveplate-compensated polarization-resolved SHG microscopy on a commercial multiphoton microscope
AU  - David Nguyen
AU  - Jeffrey P. Wilde
AU  - Virginie Uhlmann
AU  - Daniel James Smith
AU  - Justine Kusch-Wieser
AU  - Valeria Zanrè
AU  - Jakob Schwiedrzik
AU  - Gábor Csúcs
PY  - 2026
DA  - 2026/11/13
JO  - PLOS One
DO  - 10.1371/journal.pone.0357256
UR  - https://doi.org/10.1371/journal.pone.0357256
AB  - Polarization-resolved second harmonic generation microscopy provides structural information about non-centrosymmetric biological samples such as collagen. It involves illuminating the sample with a focused laser beam having a variable linear polarization angle and recording the second harmonic signal as a function of this angle. However, accurate linear polarization control is challenging due to ellipticity introduced by reflections from mirrors and dichroic mirrors in the optical path. Waveplate-based compensation has emerged as the standard approach to address these distortions, but its effectiveness for quantitative measurements remains incompletely characterized. Here, we reproduce an established automated waveplate compensation method, based on a rotating half-waveplate combined with a compensating quarter-waveplate, on a commercial Leica TCS SP8 MP multiphoton microscope, which is the same type of instrument the method was originally developed on. Despite significant effort, we consistently observed substantial unwanted residual polarization ellipticity, with amplitudes up to 0.24, persisting under optimal waveplate configurations. Our simulation analysis suggests that this limitation may arise from wavelength-dependent dichroic mirror birefringence combined with the broad spectral bandwidth (10 nm to 20 nm full width at half maximum) of femtosecond laser pulses. While the approach investigated here can compensate a single wavelength, different spectral components within the pulse experience different phase retardations from wavelength-dependent optical elements, potentially resulting in residual ellipticity that cannot be eliminated. Our simulations qualitatively reproduced key features of the experimental observations. These findings have important implications for quantitative polarization-resolved second harmonic generation microscopy and suggest that alternative approaches, including specimen rotation or picosecond laser sources with narrower bandwidth, should be investigated for applications requiring precise polarization control. To facilitate community investigation of these effects, we provide open-source analysis code and simulation files.
SN  - 1932-6203
ER  -