Skip to content
DraconiticResearch
Search Sources API
182,460 studies31 sourcesUpdated 13 min ago
Peer-reviewedCC BY 4.0Optics Express

Methane monitoring in faecal headspace gas using mid-IR laser spectroscopy with a hollow waveguide gas cell

  1. 1Cranfield University
  2. 2University of Southampton

Abstract

The feasibility of using laser spectroscopy for analysis of the headspace gas emanating from biological samples is demonstrated by monitoring the concentration of methane produced by bovine faeces. The spectrometer consists of a 7.8 µm quantum cascade laser operating in the intra-pulse mode and a 4.79 m pathlength hollow silica waveguide gas cell. Concentration measurements using known concentrations of methane demonstrate a limit of detection of 116 ppb, and Allan-Werle deviation analysis indicates a minimum detectable absorbance of 9.5 × 10 ⁻⁵ at an integration time of 45 s. A custom-designed PTFE enclosure with an embedded heating element was designed to contain the faecal samples. Filtered ambient air pumped through the instrument at a controlled rate of 5 ml/min was used to transfer the headspace gas from the sample container to the gas cell. Methane production was found to vary depending on the sample, with one sample reaching an approximate equilibrium of 13.9 ppm after 40 minutes and another, measured for longer, reaching an equilibrium of 11.4 ppm after 2 hours. These findings demonstrate the potential of laser spectroscopy for volatile biomarker analysis, with significant promise for non-invasive point-of-care diagnostics.

Related

  1. Poly(lactic acid)/ZIF-67 colorimetric headspace indicators for monitoring chicken breast freshness.
    Zahra Najafi, Leyla Nesrin Kahyaoglu
    RSC advancesPeer-reviewedCC BY-NCFull textMaterials & polymersEurope PMC
  2. Rethinking Solid-Phase Microextraction (SPME) for Bioanalysis: Workflow Optimisation in Automated Vacuum-Assisted Cooling SPME for Fatty Acid Monitoring in Faecal Waters
    Lorenza Putignani, Stefano Dugheri, Niccolò Fanfani +12
    MoleculesPeer-reviewedCC BY 4.0Full textAnalytical chemistryCrossrefEurope PMC
  3. High-Resolution X-ray Absorption Spectroscopy of Soluble Methane Monooxygenase: Room Temperature and Cryogenic Insights into Active Site Electronic Structure Modulation.
    Olivia McCubbin Stepanic, Sinjini Bhattacharjee, Christopher J Pollock +9
    Journal of the American Chemical SocietyPeer-reviewedCC BYFull textInorganic & organometallic chemistryEurope PMCPMC
  4. Study of interactions between aroma compounds and acacia gum using headspace measurements
    Géraldine Savary, Nicolas Hucher, Odile Petibon +1
    Food HydrocolloidsPeer-reviewedPublisher termsFull text24 citedAnalytical chemistryMaterials & polymersHAL
  5. Risk-Priced Radio Resources for In-Line Spectroscopy and Reaction Monitoring in Chemical Plants
    Zeyu Pan, Yating Qin, Yihang Wu +2
    ChemRxivPreprintCC BYFull textAnalytical chemistryChemRxiv
BibTeX
@article{francis2026methane,
  title = {{Methane monitoring in faecal headspace gas using mid-IR laser spectroscopy with a hollow waveguide gas cell}},
  author = {Daniel Francis and Jane Hodgkinson and Célia Lourenço and Dawn P. Fowler and Stephen E. Staines and Christopher Walton and Ralph P. Tatam},
  journal = {Optics Express},
  year = {2026},
  month = oct,
  doi = {10.1364/oe.614377},
  url = {https://opg.optica.org/abstract.cfm?URI=oe-34-21-40672},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Methane monitoring in faecal headspace gas using mid-IR laser spectroscopy with a hollow waveguide gas cell
AU  - Daniel Francis
AU  - Jane Hodgkinson
AU  - Célia Lourenço
AU  - Dawn P. Fowler
AU  - Stephen E. Staines
AU  - Christopher Walton
AU  - Ralph P. Tatam
PY  - 2026
DA  - 2026/10/16
JO  - Optics Express
DO  - 10.1364/oe.614377
UR  - https://opg.optica.org/abstract.cfm?URI=oe-34-21-40672
AB  - The feasibility of using laser spectroscopy for analysis of the headspace gas emanating from biological samples is demonstrated by monitoring the concentration of methane produced by bovine faeces. The spectrometer consists of a 7.8 µm quantum cascade laser operating in the intra-pulse mode and a 4.79 m pathlength hollow silica waveguide gas cell. Concentration measurements using known concentrations of methane demonstrate a limit of detection of 116 ppb, and Allan-Werle deviation analysis indicates a minimum detectable absorbance of 9.5 × 10 ⁻⁵ at an integration time of 45 s. A custom-designed PTFE enclosure with an embedded heating element was designed to contain the faecal samples. Filtered ambient air pumped through the instrument at a controlled rate of 5 ml/min was used to transfer the headspace gas from the sample container to the gas cell. Methane production was found to vary depending on the sample, with one sample reaching an approximate equilibrium of 13.9 ppm after 40 minutes and another, measured for longer, reaching an equilibrium of 11.4 ppm after 2 hours. These findings demonstrate the potential of laser spectroscopy for volatile biomarker analysis, with significant promise for non-invasive point-of-care diagnostics.
SN  - 1094-4087
ER  -