Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 8 min ago
Peer-reviewedCC BYJournal of applied clinical medical physics

Physics-informed depth-enhanced surface tracking for cumulative dose reconstruction in breast radiotherapy: An in silico feasibility study.

  1. 1Department of Medical Engineering, The Fourth Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China.
  2. 2Department of Radiation Oncology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China.

Abstract

Purpose

Surface guided radiotherapy (SGRT) provides nonionizing motion monitoring but lacks direct correlation with internal dosimetric changes. Purely data-driven models for surface-to-internal deformation prediction often yield biomechanically implausible results. This study proposes a physics-informed depth-enhanced (PIDE) framework, validated in silico, to reconstruct internal deformation and cumulative dose from noisy surface measurements.Methods

A virtual clinical trial (VCT) was conducted using weekly cone-beam CT (CBCT) data from 29 breast cancer patients. We simulated consumer-grade RGB-D sensor noise ( σ∝z2 ) on extracted patient surfaces. To map external surface features to internal deformation vector fields (DVF), we developed a regularized ridge regression model. Unlike traditional models, ours integrates a spectral energy penalty derived from patient-specific CBCT motion priors, constraining predictions to physically plausible deformations. Patient-specific clinical RTDOSE distributions and 348 anatomical landmarks were utilized to evaluate the dosimetric and geometric accuracy. Vector field smoothness was quantified using the Jacobian determinant.Results

Under realistic simulated sensor noise, the PIDE framework achieved an anatomical target registration error (TRE) of 1.33 ± 1.42 mm (compared to an initial misalignment of 2.14 ± 2.38 mm, representing a 37.8% error reduction). The physics-constrained regression yielded an RMSE of 2.31 mm (r = 0.720) for motion prediction and effectively eliminated nonphysical tissue "folding" artifacts (reducing negative Jacobian voxels from 0.54% to 0.10%, p = 0.0209). Dosimetric evaluation using actual patient treatment plans achieved a mean Gamma passing rate (3%/3 mm) of 99.68 ± 0.30% (range: 99.00%-100.00%), with 100% of patients (29/29) exceeding the 90% clinical safety threshold. The end-to-end algorithmic inference latency was 2.71 ms per frame, demonstrating high computational efficiency.Conclusion

The integration of geometric surface features with patient-specific physical constraints successfully prevents nonphysiological deformation artifacts caused by sensor noise. This in silico study demonstrates the feasibility and computational efficiency of the PIDE framework for rapid cumulative dose monitoring.

Related

  1. Feasibility of Urethra-Sparing Ultra-Hypofractionated Three-Dose-Level Radiotherapy for Prostate Cancer with a Dominant Intraprostatic Lesion Abutting the High-Dose Avoidance Zone.
    Annalisa Muscato, Denis La Fauci, Anna Viola +2
    Precision radiation oncologyPeer-reviewedCC BY-NC-NDFull textApplied physics & instrumentationEurope PMC
  2. Evaluating a Large Language Model for Radiotherapy Patient Scheduling under Realistic Clinical and Operational Constraints: a Feasibility Study
    Eric Zhang, Youfang Lai, Wen Li +4
    arXivPreprintCC BY 4.0Full textBiological & medical physicsarXiv
  3. Diagnostic CT-Based Palliative Radiotherapy Using kV Image Verification: A Prospective Feasibility Study.
    Kelly Wei, Jason Hui, Bradford Gill +8
    Current oncology (Toronto, Ont.)Peer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
  4. Dosimetric feasibility of lattice radiotherapy for bulky tumors: a paired VMAT vs. helical tomotherapy comparison - the STRYKE trial
    Mottareale R, Serra M, Pezzulla D +18
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossref
  5. Feasibility of reduced PTV margins in magnetic resonance image-guided online adaptive radiotherapy for bladder cancer: a personalised approach.
    Bethany Williams, Saleh Sandoughdaran, Joan Chick +7
    Clinical and translational radiation oncologyPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
BibTeX
@article{tang2026physicsinformed,
  title = {{Physics-informed depth-enhanced surface tracking for cumulative dose reconstruction in breast radiotherapy: An in silico feasibility study.}},
  author = {Xixue Tang and Minmin Qiu and Yongjin Deng},
  journal = {Journal of applied clinical medical physics},
  year = {2026},
  month = oct,
  doi = {10.1002/acm2.70890},
  url = {https://europepmc.org/article/MED/42949306},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Physics-informed depth-enhanced surface tracking for cumulative dose reconstruction in breast radiotherapy: An in silico feasibility study.
AU  - Xixue Tang
AU  - Minmin Qiu
AU  - Yongjin Deng
PY  - 2026
DA  - 2026/10/28
JO  - Journal of applied clinical medical physics
DO  - 10.1002/acm2.70890
UR  - https://europepmc.org/article/MED/42949306
AB  - Purpose  Surface guided radiotherapy (SGRT) provides nonionizing motion monitoring but lacks direct correlation with internal dosimetric changes. Purely data-driven models for surface-to-internal deformation prediction often yield biomechanically implausible results. This study proposes a physics-informed depth-enhanced (PIDE) framework, validated in silico, to reconstruct internal deformation and cumulative dose from noisy surface measurements.Methods  A virtual clinical trial (VCT) was conducted using weekly cone-beam CT (CBCT) data from 29 breast cancer patients. We simulated consumer-grade RGB-D sensor noise ( σ∝z2 ) on extracted patient surfaces. To map external surface features to internal deformation vector fields (DVF), we developed a regularized ridge regression model. Unlike traditional models, ours integrates a spectral energy penalty derived from patient-specific CBCT motion priors, constraining predictions to physically plausible deformations. Patient-specific clinical RTDOSE distributions and 348 anatomical landmarks were utilized to evaluate the dosimetric and geometric accuracy. Vector field smoothness was quantified using the Jacobian determinant.Results  Under realistic simulated sensor noise, the PIDE framework achieved an anatomical target registration error (TRE) of 1.33 ± 1.42 mm (compared to an initial misalignment of 2.14 ± 2.38 mm, representing a 37.8% error reduction). The physics-constrained regression yielded an RMSE of 2.31 mm (r = 0.720) for motion prediction and effectively eliminated nonphysical tissue "folding" artifacts (reducing negative Jacobian voxels from 0.54% to 0.10%, p = 0.0209). Dosimetric evaluation using actual patient treatment plans achieved a mean Gamma passing rate (3%/3 mm) of 99.68 ± 0.30% (range: 99.00%-100.00%), with 100% of patients (29/29) exceeding the 90% clinical safety threshold. The end-to-end algorithmic inference latency was 2.71 ms per frame, demonstrating high computational efficiency.Conclusion  The integration of geometric surface features with patient-specific physical constraints successfully prevents nonphysiological deformation artifacts caused by sensor noise. This in silico study demonstrates the feasibility and computational efficiency of the PIDE framework for rapid cumulative dose monitoring.
SN  - 1526-9914
ER  -