Retrieval of a Broken Cannulated Drill Bit from the Femoral Neck during Proximal Femoral Nailing: Case Report of a Novel Lever Technique Using a Depth Gauge.
- 1Department of Orthopaedics, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, India.
Abstract
Intraoperative drill bit breakage is a recognised complication in orthopaedic trauma surgery. Although retained broken drill bits embedded deep within bone are generally considered benign, their removal becomes mandatory when they obstruct optimal implant placement for fracture fixation, risk migration, or carry medicolegal implications. We describe the case of a male patient in his mid-sixties who sustained a left intertrochanteric femur fracture and underwent proximal femoral nailing (PFN). During reaming for the compression screw, an 8 mm cannulated drill bit fractured and became lodged within the femoral neck over the guide wire. A novel lever technique using a standard PFN-set depth gauge was employed. The hooked tip of the depth gauge was passed through the lumen of the broken cannulated drill bit under fluoroscopic guidance. The instrument was then rotated so that the hook faced medially, and the external arm was levered laterally away from the limb to engage the hook firmly against the medial wall of the broken fragment. Gentle traction successfully retrieved the drill bit, allowing completion of fracture fixation with a new drill bit in the optimal tip-apex position. This technique is safe, reproducible, and time-efficient. It requires no additional incisions, no specialized instrumentation beyond the standard PFN set, and provides secure mechanical engagement of the fragment before extraction. We recommend this approach for similar intraoperative situations.
Related
- Fully Threaded Versus Partially Threaded Cannulated Screws in the Treatment of Nondisplaced or Valgus-Impacted Geriatric Femoral Neck Fractures: A Retrospective Cohort Study
- Surgical Technique – The “Derriere View” for Evaluation of Guidewire Position in Cephalomedullary Nailing of Intertrochanteric Femur Fractures
- Lateral-Only Flexible Intramedullary Nailing for Pediatric Tibial Shaft Fractures: An Early Comparative Experience With a Novel Technique to Reduce Symptomatic Implant Prominence
- Is there a difference between Fully Threaded and Partially Threaded Cannulated Screws for In Situ Pinning of Slipped Capital Femoral Epiphysis?
- Early clinical and radiographic outcomes of robot-assisted femoral neck system fixation combined with an additional cannulated compression screw for garden IV femoral neck fractures in young and middle-aged adults: a propensity score-matched retrospective cohort study.
BibTeX
@article{patil2026retrieval,
title = {{Retrieval of a Broken Cannulated Drill Bit from the Femoral Neck during Proximal Femoral Nailing: Case Report of a Novel Lever Technique Using a Depth Gauge.}},
author = {Rakshith N Patil and Vikram G K Bhat and Naman Mittal and Akshit Khandelwal and G N Sudhanva},
journal = {Journal of orthopaedic case reports},
year = {2026},
month = nov,
doi = {10.13107/jocr.2026.v16.i11.8408},
url = {https://europepmc.org/article/MED/42997104},
note = {CC BY-NC},
}
RIS
TY - JOUR
TI - Retrieval of a Broken Cannulated Drill Bit from the Femoral Neck during Proximal Femoral Nailing: Case Report of a Novel Lever Technique Using a Depth Gauge.
AU - Rakshith N Patil
AU - Vikram G K Bhat
AU - Naman Mittal
AU - Akshit Khandelwal
AU - G N Sudhanva
PY - 2026
DA - 2026/11/01
JO - Journal of orthopaedic case reports
DO - 10.13107/jocr.2026.v16.i11.8408
UR - https://europepmc.org/article/MED/42997104
AB - Intraoperative drill bit breakage is a recognised complication in orthopaedic trauma surgery. Although retained broken drill bits embedded deep within bone are generally considered benign, their removal becomes mandatory when they obstruct optimal implant placement for fracture fixation, risk migration, or carry medicolegal implications. We describe the case of a male patient in his mid-sixties who sustained a left intertrochanteric femur fracture and underwent proximal femoral nailing (PFN). During reaming for the compression screw, an 8 mm cannulated drill bit fractured and became lodged within the femoral neck over the guide wire. A novel lever technique using a standard PFN-set depth gauge was employed. The hooked tip of the depth gauge was passed through the lumen of the broken cannulated drill bit under fluoroscopic guidance. The instrument was then rotated so that the hook faced medially, and the external arm was levered laterally away from the limb to engage the hook firmly against the medial wall of the broken fragment. Gentle traction successfully retrieved the drill bit, allowing completion of fracture fixation with a new drill bit in the optimal tip-apex position. This technique is safe, reproducible, and time-efficient. It requires no additional incisions, no specialized instrumentation beyond the standard PFN set, and provides secure mechanical engagement of the fragment before extraction. We recommend this approach for similar intraoperative situations.
SN - 2250-0685
SN - 2321-3817
ER -