Fast On-Chip Thermometry with TiN Kinetic Inductance Resonators in 22 nm Process Technology
Abstract
Understanding the temporal and spatial dependence of temperature is critical in high-performance cryogenic devices. Typical thermometry techniques struggle to simultaneously combine high bandwidth, sensitivity and on-chip integration, limiting their ability to measure fast intra-device thermal fluctuations. Here, we demonstrate a time-resolved thermometry platform based on TiN kinetic inductance resonators integrated in a 22 nm FDSOI chip. By tracking temperature-dependent shifts in the resonant frequency, we achieve sub-millikelvin temperature sensitivity down to temperatures of 100 mK. Time-resolved on-chip pulsed heating experiments as a function of distance reveal an onset delay, consistent with a quasi-ballistic heat propagation velocity of 3.9 ± 0.1 mm μs−1. We also show that elevated temperatures increase net thermal conductance, shortening thermal relaxation times across all spatial separations. This behaviour manifests in two distinct regimes: a substrate-limited regime at 100 mK, where cooling rates vary with heater distance, and a Kapitza boundary-limited regime at 400 mK, where thermal relaxation becomes more spatially uniform. These measurements demonstrate kinetic inductance thermometry's ability to rapidly probe non-equilibrium temperature dynamics in cryogenic devices such as quantum processors.
Related
- Giant nonlinearity of kinetic inductance in superconducting hybrid strip
- Near-Quantum-Limited Readout for the Princeton Axion Search using a sub-GHz Kinetic Inductance Traveling Wave Parametric Amplifier
- Thin-film nanostructuring of NbTi superconducting resonators for enhanced temperature sensitivity in cryogenic thermometry
- Kinetic-inductance Parametric Amplification in Superconducting Hybrid Magnonics
- Post-fabrication trimming of a 1024-pixel, single-photon counting, Microwave Kinetic Inductance Detector array with a pixel pitch of 150 micron
BibTeX
@misc{drayne2026fast,
title = {{Fast On-Chip Thermometry with TiN Kinetic Inductance Resonators in 22 nm Process Technology}},
author = {Johann Drayne and George Ridgard and Lorenzo Peri and Frederic Schlattner and Fabio Olivieri and Mathieu de Kruijf and Isaac Harris and Grayson Noah and James Kirkman and Alberto Gomez-Saiz and M. Fernando Gonzalez-Zalba and Thomas Swift},
howpublished = {arXiv},
year = {2026},
month = aug,
doi = {10.48550/arxiv.2608.27057},
eprint = {2608.27057},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2608.27057},
}
RIS
TY - UNPB
TI - Fast On-Chip Thermometry with TiN Kinetic Inductance Resonators in 22 nm Process Technology
AU - Johann Drayne
AU - George Ridgard
AU - Lorenzo Peri
AU - Frederic Schlattner
AU - Fabio Olivieri
AU - Mathieu de Kruijf
AU - Isaac Harris
AU - Grayson Noah
AU - James Kirkman
AU - Alberto Gomez-Saiz
AU - M. Fernando Gonzalez-Zalba
AU - Thomas Swift
PY - 2026
DA - 2026/08/28
PB - arXiv
DO - 10.48550/arxiv.2608.27057
UR - https://arxiv.org/abs/2608.27057
AB - Understanding the temporal and spatial dependence of temperature is critical in high-performance cryogenic devices. Typical thermometry techniques struggle to simultaneously combine high bandwidth, sensitivity and on-chip integration, limiting their ability to measure fast intra-device thermal fluctuations. Here, we demonstrate a time-resolved thermometry platform based on TiN kinetic inductance resonators integrated in a 22 nm FDSOI chip. By tracking temperature-dependent shifts in the resonant frequency, we achieve sub-millikelvin temperature sensitivity down to temperatures of 100 mK. Time-resolved on-chip pulsed heating experiments as a function of distance reveal an onset delay, consistent with a quasi-ballistic heat propagation velocity of 3.9 ± 0.1 mm μs^−1. We also show that elevated temperatures increase net thermal conductance, shortening thermal relaxation times across all spatial separations. This behaviour manifests in two distinct regimes: a substrate-limited regime at 100 mK, where cooling rates vary with heater distance, and a Kapitza boundary-limited regime at 400 mK, where thermal relaxation becomes more spatially uniform. These measurements demonstrate kinetic inductance thermometry's ability to rapidly probe non-equilibrium temperature dynamics in cryogenic devices such as quantum processors.
ER -