Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BYCureus

Late-Onset Prosthetic Valve Dysfunction Associated With Hypoattenuated Leaflet Thickening Detected After a New Heart Murmur: A Case Report.

  1. 1Division of Cardiovascular Surgery, Department of Surgery, Kurume University, Kurume, JPN.

Abstract

Hypoattenuated leaflet thickening (HALT) is increasingly recognized after bioprosthetic aortic valve replacement; however, its clinical significance and optimal detection strategy in routine practice remain uncertain. We report the case of a 79-year-old woman who underwent minimally invasive aortic valve replacement using a Perceval S sutureless bioprosthesis for severe aortic stenosis. Early postoperative transthoracic echocardiography and cardiac computed tomography demonstrated normal prosthetic valve function without evidence of HALT. Oral anticoagulation was discontinued three months after surgery, and the patient remained asymptomatic. At the one-year follow-up visit, a newly detected systolic heart murmur prompted further evaluation despite stable N-terminal pro-B-type natriuretic peptide levels. Echocardiography revealed increased transvalvular gradients and mild-to-moderate transvalvular regurgitation, while cardiac computed tomography demonstrated HALT involving the right and noncoronary cusps. The combination of hemodynamically significant prosthetic valve dysfunction and CT-confirmed HALT was considered consistent with clinically overt bioprosthetic valve thrombosis. Oral anticoagulation was restarted, followed by complete resolution of HALT and improvement in prosthetic valve hemodynamics. This case demonstrates that clinically overt bioprosthetic valve thrombosis associated with HALT may develop in an asymptomatic patient and that a newly detected cardiac murmur may serve as a clinical trigger for further echocardiographic and CT evaluation. Careful routine clinical follow-up may facilitate recognition of hemodynamically relevant prosthetic valve dysfunction and appropriate therapeutic intervention.

Related

  1. Skirted Prosthetic Valves Are Associated With Increased Risk of Subclinical Leaflet Thrombosis Following Transcatheter Aortic Valve Replacement: A Multicenter Study
    Yifan Yang, Qiang Li, Jing Yao +9
    Reviews in cardiovascular medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. A smaller preoperative-to-prosthetic center of rotation shift is associated with better range of motion after bony increased-offset reverse shoulder arthroplasty: A retrospective cohort study of 97 patients by the FP-UCBM Shoulder Group
    Mauro Ciuffreda, Piergianni Luigi Di Santo, Antonino De Rosa +7
    Shoulder & ElbowPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  3. Central Nervous System Methotrexate-associated Lymphoproliferative Disorder Presenting with Progressive Dural Thickening
    Hiroki USHITA, Akimitsu SHIROKIHARA, Saho WAKAMATSU +2
    NMC Case Report JournalPeer-reviewedCC BY-NC-ND 4.0Full textNeurologyPMC
  4. Actinotignum-associated prosthetic aortic valve endocarditis complicated by postoperative circulatory collapse and dialysis-requiring acute kidney injury: a case report.
    Norihiro Sakai, Aya Seki, Tomohiro Michino
    BMC infectious diseasesPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCPMC
  5. Colonic Metastases from Lung Adenocarcinoma Detected During an Evaluation of Recurrent Diarrhea Associated with Immune-Related Colitis
    Naohito Hashimoto, Yoshiaki Nagai, Konjo Cho +7
    Internal MedicinePeer-reviewedCC BY-NC-NDFull text1 citedOncologyJ-STAGE
BibTeX
@article{takagi2026lateonset,
  title = {{Late-Onset Prosthetic Valve Dysfunction Associated With Hypoattenuated Leaflet Thickening Detected After a New Heart Murmur: A Case Report.}},
  author = {Kazuyoshi Takagi and Kosuke Saku and Hiroki Mine and Takanori Kono and Eiki Tayama},
  journal = {Cureus},
  year = {2026},
  month = sep,
  doi = {10.7759/cureus.116665},
  url = {https://europepmc.org/article/MED/42910355},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Late-Onset Prosthetic Valve Dysfunction Associated With Hypoattenuated Leaflet Thickening Detected After a New Heart Murmur: A Case Report.
AU  - Kazuyoshi Takagi
AU  - Kosuke Saku
AU  - Hiroki Mine
AU  - Takanori Kono
AU  - Eiki Tayama
PY  - 2026
DA  - 2026/09/21
JO  - Cureus
DO  - 10.7759/cureus.116665
UR  - https://europepmc.org/article/MED/42910355
AB  - Hypoattenuated leaflet thickening (HALT) is increasingly recognized after bioprosthetic aortic valve replacement; however, its clinical significance and optimal detection strategy in routine practice remain uncertain. We report the case of a 79-year-old woman who underwent minimally invasive aortic valve replacement using a Perceval S sutureless bioprosthesis for severe aortic stenosis. Early postoperative transthoracic echocardiography and cardiac computed tomography demonstrated normal prosthetic valve function without evidence of HALT. Oral anticoagulation was discontinued three months after surgery, and the patient remained asymptomatic. At the one-year follow-up visit, a newly detected systolic heart murmur prompted further evaluation despite stable N-terminal pro-B-type natriuretic peptide levels. Echocardiography revealed increased transvalvular gradients and mild-to-moderate transvalvular regurgitation, while cardiac computed tomography demonstrated HALT involving the right and noncoronary cusps. The combination of hemodynamically significant prosthetic valve dysfunction and CT-confirmed HALT was considered consistent with clinically overt bioprosthetic valve thrombosis. Oral anticoagulation was restarted, followed by complete resolution of HALT and improvement in prosthetic valve hemodynamics. This case demonstrates that clinically overt bioprosthetic valve thrombosis associated with HALT may develop in an asymptomatic patient and that a newly detected cardiac murmur may serve as a clinical trigger for further echocardiographic and CT evaluation. Careful routine clinical follow-up may facilitate recognition of hemodynamically relevant prosthetic valve dysfunction and appropriate therapeutic intervention.
SN  - 2168-8184
ER  -