Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 43 min ago
Peer-reviewedCC BY 4.0Pediatric Radiology

Evaluation of a novel flexible, lightweight blanket-like torso coil in pediatric MRI at 1.5-T – initial experience

  1. 1Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH 45229 United States
  2. 2Department of Radiology, University of Cincinnati, Cincinnati, United States
  3. 3Philips Healthcare, Best, Netherlands

Abstract

Background: Conventional phased-array torso coils used for abdominal MRI are relatively heavy and inflexible, potentially affecting patient comfort and technologist workflow.

Objective: To compare image quality, patient experience, and technologist experience using a recently United States Food and Drug Administration-cleared flexible, lightweight, blanket-like torso coil versus a conventional torso coil for pediatric abdominal MRI.

Materials and methods: In this prospective institutional review board-approved study, 20 pediatric patients (7 years-old to 18 years-old) undergoing routine clinical outpatient abdominal MRI were imaged on the same 1.5-T system using both a conventional torso coil and a flexible blanket-like torso coil (Smart Fit TorsoCardiac; Philips Healthcare). After standard clinical imaging, selected sequences were repeated following coil exchange. Five pediatric radiologists independently evaluated paired image sets for subjective signal-to-noise ratio (SNR) and coil-related artifacts. Objective image quality was assessed using organ- and tissue-based SNR estimates and contrast-to-noise ratio (CNR) measurements. Patients and MRI technologists completed questionnaires regarding comfort, usability, and examination experience.

Results: All 20 patients (median age, 15 years; 55% female) underwent imaging with both coils. Radiologists rated the novel coil as similar to the conventional coil for subjective SNR across all three sequences under study; coil-related artifacts were uncommon (2% of assessments for all sequences evaluated). Objective analysis showed no significant image-based SNR differences for most sequences, although the flexible coil demonstrated higher liver SNR on axial diffusion-weighted imaging (adjusted P=0.01). CNR did not differ between coils. Patients reported greater comfort and less anxiety with the flexible coil; 55% preferred it for future MRI examinations versus 20% for the conventional coil. Technologists also favored the flexible coil, with 70% expressing an overall preference.

Conclusion: The flexible blanket-like torso coil provided image quality similar to a conventional coil and was generally preferred by patients and MRI technologists.

Related

  1. Lateral-Only Flexible Intramedullary Nailing for Pediatric Tibial Shaft Fractures: An Early Comparative Experience With a Novel Technique to Reduce Symptomatic Implant Prominence
    Alan D. Villegas Meza, Matthew Allen, Brendon C. Mitchell +2
    Journal of the Pediatric Orthopaedic Society of North AmericaPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Perioperative shear wave elastography for the evaluation of spinal cord release in pediatric dysraphism: first experience in 21 patients
    Mathilde Gaume, Lou Richard, Claudio Vergari +4
    Journal of Neurosurgery: SpinePeer-reviewedPublisher termsFull textMedical imaging & radiologyHAL
  3. Infant Formula-Based Oral Lyophilizates for Personalized Pediatric Drug Delivery: Development of Flexible-Dose Loratadine Formulations and In Vivo Evaluation
    Rareș Iovanov, Dana Muntean, Sonia Iurian +5
    Applied SciencesPeer-reviewedCC BYFull textObstetrics, gynaecology & paediatricsDOAJ
  4. Lightweight MFCC-SVM recognition of wheeze events in pediatric respiratory sounds: inter-patient evaluation on SPRSound and a software deployment proof-of-concept.
    Percy De-la-Cruz-VdV, Luis Guadalupe-Chacaltana, Hugo Vega-Huerta +9
    Frontiers in digital healthPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Lateral-Only Flexible Intramedullary Nailing for Pediatric Tibial Shaft Fractures: An Early Comparative Experience With a Novel Technique to Reduce Symptomatic Implant Prominence
    Alan D. Villegas Meza, BA, Matthew Allen, BA, Brendon C. Mitchell, MD +2
    Journal of the Pediatric Orthopaedic Society of North AmericaPeer-reviewedCC BYFull textEpidemiology & public healthDOAJEurope PMCPMC
BibTeX
@article{dillman2026evaluation,
  title = {{Evaluation of a novel flexible, lightweight blanket-like torso coil in pediatric MRI at 1.5-T – initial experience}},
  author = {Jonathan R. Dillman and Jean A. Tkach and R. Paul Guillerman and Murat Kocaoglu and Yinan Li and Michael P. Nasser and Adam F. Prasanphanich and Amol Pednekar and Ashan Kharzai and Joshua Greer and Jonathan A. Dudley},
  journal = {Pediatric Radiology},
  year = {2026},
  month = aug,
  doi = {10.1007/s00247-026-06761-5},
  url = {https://doi.org/10.1007/s00247-026-06761-5},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Evaluation of a novel flexible, lightweight blanket-like torso coil in pediatric MRI at 1.5-T – initial experience
AU  - Jonathan R. Dillman
AU  - Jean A. Tkach
AU  - R. Paul Guillerman
AU  - Murat Kocaoglu
AU  - Yinan Li
AU  - Michael P. Nasser
AU  - Adam F. Prasanphanich
AU  - Amol Pednekar
AU  - Ashan Kharzai
AU  - Joshua Greer
AU  - Jonathan A. Dudley
PY  - 2026
DA  - 2026/08/22
JO  - Pediatric Radiology
DO  - 10.1007/s00247-026-06761-5
UR  - https://doi.org/10.1007/s00247-026-06761-5
AB  - Background: Conventional phased-array torso coils used for abdominal MRI are relatively heavy and inflexible, potentially affecting patient comfort and technologist workflow.  Objective: To compare image quality, patient experience, and technologist experience using a recently United States Food and Drug Administration-cleared flexible, lightweight, blanket-like torso coil versus a conventional torso coil for pediatric abdominal MRI.  Materials and methods: In this prospective institutional review board-approved study, 20 pediatric patients (7 years-old to 18 years-old) undergoing routine clinical outpatient abdominal MRI were imaged on the same 1.5-T system using both a conventional torso coil and a flexible blanket-like torso coil (Smart Fit TorsoCardiac; Philips Healthcare). After standard clinical imaging, selected sequences were repeated following coil exchange. Five pediatric radiologists independently evaluated paired image sets for subjective signal-to-noise ratio (SNR) and coil-related artifacts. Objective image quality was assessed using organ- and tissue-based SNR estimates and contrast-to-noise ratio (CNR) measurements. Patients and MRI technologists completed questionnaires regarding comfort, usability, and examination experience.  Results: All 20 patients (median age, 15 years; 55% female) underwent imaging with both coils. Radiologists rated the novel coil as similar to the conventional coil for subjective SNR across all three sequences under study; coil-related artifacts were uncommon (2% of assessments for all sequences evaluated). Objective analysis showed no significant image-based SNR differences for most sequences, although the flexible coil demonstrated higher liver SNR on axial diffusion-weighted imaging (adjusted P=0.01). CNR did not differ between coils. Patients reported greater comfort and less anxiety with the flexible coil; 55% preferred it for future MRI examinations versus 20% for the conventional coil. Technologists also favored the flexible coil, with 70% expressing an overall preference.  Conclusion: The flexible blanket-like torso coil provided image quality similar to a conventional coil and was generally preferred by patients and MRI technologists.
SN  - 0301-0449
SN  - 1432-1998
ER  -