Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BYFrontiers in digital health

Lightweight MFCC-SVM recognition of wheeze events in pediatric respiratory sounds: inter-patient evaluation on SPRSound and a software deployment proof-of-concept.

5 affiliations
  1. 1Universidad Nacional Mayor de San Marcos, Lima, Perú.
  2. 2Universidad Ricardo Palma, Lima, Perú.
  3. 3Universidad Nacional Intercultural de la Amazonía, Ucayali, Perú.
  4. 4Universidad Científica del Sur, Lima, Perú.
  5. 5Universidad Nacional de Educación Enrique Guzmán y Valle, Lima, Perú.

Abstract

Pediatric wheeze recognition can support the automated analysis of respiratory sounds and reduce dependence on subjective auscultation. This study develops and evaluates a lightweight machine-learning approach for event-level wheeze/no-wheeze recognition using the publicly available SPRSound pediatric respiratory sound database. Respiratory events were extracted exclusively from the expert-annotated temporal boundaries provided with the dataset, without automatic event segmentation. A total of 9,089 annotated respiratory events were represented using Mel-frequency cepstral coefficients (MFCCs), delta, and delta-delta features summarized into a fixed 120-dimensional vector. Logistic Regression, Linear Support Vector Machine, Random Forest, and Support Vector Machine with a radial basis function kernel (SVM-RBF) were evaluated under the same acoustic-feature pipeline. The operating threshold of the SVM-RBF classifier was optimized using the INTRA-2022 partition and subsequently applied to the inter-patient INTER-2022 partition. At this operating point, the model achieved a sensitivity of 0.935 (95% CI 0.901-0.957), specificity of 0.777 (95% CI 0.752-0.801), ROC-AUC of 0.930, PR-AUC of 0.772, and F1-score of 0.679; the positive predictive value was 0.534, reflecting a substantial false-positive burden. As a secondary software-level contribution, the trained preprocessing and classification components were integrated into an Android-Flask client-server workflow for audio submission, server-side feature extraction, inference, and result visualization. The software workflow was functionally implemented but was not quantitatively validated using respiratory recordings acquired through a smartphone microphone. Accordingly, the reported performance characterizes event-level classification under SPRSound conditions and should not be interpreted as mobile-acquisition, diagnostic, or clinical validation.

Related

  1. Evaluation of a novel flexible, lightweight blanket-like torso coil in pediatric MRI at 1.5-T – initial experience
    Jonathan R. Dillman, Jean A. Tkach, R. Paul Guillerman +8
    Pediatric RadiologyPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyPMC
  2. Lightweight multi-task network for synchronous fatigue detection and ankle instability gait analysis in football training with edge deployment
    Zou Maoning
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  3. Lightweight convolutional neural networks for detecting middle cerebral artery stenosis on TCD spectral images: discriminative performance, probability calibration and deployment value
    Qian Zhao, Li Sun, Nannan Li +1
    Frontiers in NeurologyPeer-reviewedCC BY 4.0NeurologyCrossref
  4. Cattle posture recognition in complex farm environments with real-time edge deployment
    Shangyang Ju, Haohui Peng, Zhongbin Yan +3
    PLOS OnePeer-reviewedCC BYFull textZoology & animal behaviourStatisticsPLOSEurope PMCPMC
  5. CNN-based dual-morphology mosquito recognition and mobile deployment
    Lei Zhu, Jiahao Duan, Jing Wang +4
    PLOS OnePeer-reviewedCC BY 4.0Full textZoology & animal behaviourPhysiologyPLOS
BibTeX
@article{delacruzvdv2026lightweight,
  title = {{Lightweight MFCC-SVM recognition of wheeze events in pediatric respiratory sounds: inter-patient evaluation on SPRSound and a software deployment proof-of-concept.}},
  author = {Percy De-la-Cruz-VdV and Luis Guadalupe-Chacaltana and Hugo Vega-Huerta and Javier Elmer Cabrera-Diaz and Adegundo Camara-Figueroa and Antonio Mambret Luna-Figueroa and Maria Laura Barrera Cajachagua and Mario Chauca and Juan Carlos Lázaro-Guillermo and Jessy Vargas-Flores and Katherin Vanessa Rodriguez-Zevallos and Moisés Niño-Cueva},
  journal = {Frontiers in digital health},
  year = {2026},
  month = nov,
  doi = {10.3389/fdgth.2026.1963067},
  url = {https://europepmc.org/article/MED/43080345},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Lightweight MFCC-SVM recognition of wheeze events in pediatric respiratory sounds: inter-patient evaluation on SPRSound and a software deployment proof-of-concept.
AU  - Percy De-la-Cruz-VdV
AU  - Luis Guadalupe-Chacaltana
AU  - Hugo Vega-Huerta
AU  - Javier Elmer Cabrera-Diaz
AU  - Adegundo Camara-Figueroa
AU  - Antonio Mambret Luna-Figueroa
AU  - Maria Laura Barrera Cajachagua
AU  - Mario Chauca
AU  - Juan Carlos Lázaro-Guillermo
AU  - Jessy Vargas-Flores
AU  - Katherin Vanessa Rodriguez-Zevallos
AU  - Moisés Niño-Cueva
PY  - 2026
DA  - 2026/11/10
JO  - Frontiers in digital health
DO  - 10.3389/fdgth.2026.1963067
UR  - https://europepmc.org/article/MED/43080345
AB  - Pediatric wheeze recognition can support the automated analysis of respiratory sounds and reduce dependence on subjective auscultation. This study develops and evaluates a lightweight machine-learning approach for event-level wheeze/no-wheeze recognition using the publicly available SPRSound pediatric respiratory sound database. Respiratory events were extracted exclusively from the expert-annotated temporal boundaries provided with the dataset, without automatic event segmentation. A total of 9,089 annotated respiratory events were represented using Mel-frequency cepstral coefficients (MFCCs), delta, and delta-delta features summarized into a fixed 120-dimensional vector. Logistic Regression, Linear Support Vector Machine, Random Forest, and Support Vector Machine with a radial basis function kernel (SVM-RBF) were evaluated under the same acoustic-feature pipeline. The operating threshold of the SVM-RBF classifier was optimized using the INTRA-2022 partition and subsequently applied to the inter-patient INTER-2022 partition. At this operating point, the model achieved a sensitivity of 0.935 (95% CI 0.901-0.957), specificity of 0.777 (95% CI 0.752-0.801), ROC-AUC of 0.930, PR-AUC of 0.772, and F1-score of 0.679; the positive predictive value was 0.534, reflecting a substantial false-positive burden. As a secondary software-level contribution, the trained preprocessing and classification components were integrated into an Android-Flask client-server workflow for audio submission, server-side feature extraction, inference, and result visualization. The software workflow was functionally implemented but was not quantitatively validated using respiratory recordings acquired through a smartphone microphone. Accordingly, the reported performance characterizes event-level classification under SPRSound conditions and should not be interpreted as mobile-acquisition, diagnostic, or clinical validation.
SN  - 2673-253X
ER  -