Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 56 min ago
Peer-reviewedCC BY 4.0Journal of Clinical Medicine

Correlates of Fetal Aortic Isthmus Diameter in Fetuses Considered Structurally Normal on Second-Trimester Assessment

  1. 1Division of Perinatology, Department of Obstetrics and Gynecology, Faculty of Medicine, Selçuk University—Alaeddin Keykubat Campus, 42130 Konya, Türkiye
  2. 2Department of Obstetrics and Gynecology, Faculty of Medicine, Selçuk University—Alaeddin Keykubat Campus, 42130 Konya, Türkiye

Abstract

Background/Objectives: Fetal aortic isthmus reference data have characterized its size as a function of gestational age; whether aortic and pulmonary valve diameters are associated with isthmic caliber in addition to gestational age has not been systematically examined. We examined the correlates of aortic isthmus diameter in fetuses considered structurally normal on second-trimester assessment. Methods: This retrospective single-center cohort study included 472 fetuses considered structurally normal on second-trimester assessment at 19 + 0–24 + 6 weeks. Aortic isthmus (AoI), aortic valve (AV), pulmonary valve (PV) and thymic transverse diameters were measured by a single operator. Three-step hierarchical linear regression modeled the AoI diameter (Model 1, gestational age; Model 2, +AV and PV; Model 3, +thymus), with variance inflation factors, regression diagnostics and internal validation conducted via repeated five-fold cross-validation (100 repeats). For sensitivity analyses, the gestational-age equivalents recorded in the clinical reports for femur length, biparietal diameter and head circumference were converted into total days and analyzed as continuous variables in place of the clinical gestational age. Results: AoI diameter was correlated with gestational age (r = 0.512), AV (r = 0.507), PV (r = 0.516) and thymic diameter (r = 0.397) (all p < 0.001). Gestational age alone accounted for 26.2% of the variance (R2 = 0.262). Adding AV and PV increased the explained variance (ΔR2 = 0.060; total R2 = 0.322; p < 0.001); both AV (β = 0.186; p = 0.005) and PV (β = 0.187; p = 0.006) were independently associated with isthmic caliber, and the highest VIF in Model 2 was 3.22. Adding thymic diameter produced no meaningful increment (ΔR2 = 0.0003; p = 0.636). Across the four size-index specifications, the valve-term increment ranged from 0.037 to 0.060. Internal validation via repeated five-fold cross-validation gave a mean cross-validated R2 of 0.299 (SD of repeat-specific means, 0.011). Conclusions: In fetuses considered structurally normal on second-trimester assessment, aortic isthmus diameter was associated with gestational age, and, in addition, with aortic and pulmonary valve diameters, which accounted for a modest further share of the variance. No independent association with thymic diameter was demonstrated.

Related

  1. Real-time three-dimensional echocardiographic assessment of the association between aortic diameter and left ventricular mechanical dyssynchrony in patients with bicuspid aortic valve
    Huan Liu, Xueting Guo, Kunxuan Liu +7
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  2. Prevalence and Clinical Correlates of Coronary Perivascular Inflammation in an Asymptomatic Adult Primary Prevention Population: An Assessment of the CT-Derived Fat Attenuation Index Score (FAI-Score)
    D. Stan, J. Fu, M. Ngov +1
    medRxivPreprintAll rights reservedFull textCardiovascular medicinemedRxiv
  3. Cognitive Control Neural Correlates of Negative Affective in Psychosis Spectrum Disorders: A Laboratory and Ecological Momentary Assessment Study
    Takakuni Suzuki, Margo W. Menkes, Maureen Walton +5
    PsyArXivPreprintCC BY 4.0Full textNeurosciencePsychiatry & mental healthOSF
  4. Should obesity be considered a contraindication to mini-invasive pancreaticoduodenectomy?
    Antonio Iannelli, Sébastien Frey, Tarek Debs +1
    Seminars in Laparoscopic SurgeryPeer-reviewedCC BY-NC-NDFull textGeneral biologySurgery & anaesthesiaHAL
  5. Should the carbon footprint of imaging be considered to ensure an effective, sustainable supplementary breast screening strategy for women with dense breasts?
    Jennifer Isautier, Nehmat Houssami, Alexandra Barratt +3
    Public Health Research & PracticePeer-reviewedCC BY-NCFull textMedical imaging & radiologyDOAJ
BibTeX
@article{beyhekim2026correlates,
  title = {{Correlates of Fetal Aortic Isthmus Diameter in Fetuses Considered Structurally Normal on Second-Trimester Assessment}},
  author = {Hasan Beyhekim and Fatma Beyhekim and Zekiye Soykan Sert and Elif Betül Esmer and Mete Bertizlioğlu and Görkem Aktaş and Gökçen Örgül and Aybike Tazegül Pekin},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  month = oct,
  doi = {10.3390/jcm15207798},
  url = {https://www.mdpi.com/2077-0383/15/20/7798},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Correlates of Fetal Aortic Isthmus Diameter in Fetuses Considered Structurally Normal on Second-Trimester Assessment
AU  - Hasan Beyhekim
AU  - Fatma Beyhekim
AU  - Zekiye Soykan Sert
AU  - Elif Betül Esmer
AU  - Mete Bertizlioğlu
AU  - Görkem Aktaş
AU  - Gökçen Örgül
AU  - Aybike Tazegül Pekin
PY  - 2026
DA  - 2026/10/09
JO  - Journal of Clinical Medicine
DO  - 10.3390/jcm15207798
UR  - https://www.mdpi.com/2077-0383/15/20/7798
AB  - Background/Objectives: Fetal aortic isthmus reference data have characterized its size as a function of gestational age; whether aortic and pulmonary valve diameters are associated with isthmic caliber in addition to gestational age has not been systematically examined. We examined the correlates of aortic isthmus diameter in fetuses considered structurally normal on second-trimester assessment. Methods: This retrospective single-center cohort study included 472 fetuses considered structurally normal on second-trimester assessment at 19 + 0–24 + 6 weeks. Aortic isthmus (AoI), aortic valve (AV), pulmonary valve (PV) and thymic transverse diameters were measured by a single operator. Three-step hierarchical linear regression modeled the AoI diameter (Model 1, gestational age; Model 2, +AV and PV; Model 3, +thymus), with variance inflation factors, regression diagnostics and internal validation conducted via repeated five-fold cross-validation (100 repeats). For sensitivity analyses, the gestational-age equivalents recorded in the clinical reports for femur length, biparietal diameter and head circumference were converted into total days and analyzed as continuous variables in place of the clinical gestational age. Results: AoI diameter was correlated with gestational age (r = 0.512), AV (r = 0.507), PV (r = 0.516) and thymic diameter (r = 0.397) (all p < 0.001). Gestational age alone accounted for 26.2% of the variance (R2 = 0.262). Adding AV and PV increased the explained variance (ΔR2 = 0.060; total R2 = 0.322; p < 0.001); both AV (β = 0.186; p = 0.005) and PV (β = 0.187; p = 0.006) were independently associated with isthmic caliber, and the highest VIF in Model 2 was 3.22. Adding thymic diameter produced no meaningful increment (ΔR2 = 0.0003; p = 0.636). Across the four size-index specifications, the valve-term increment ranged from 0.037 to 0.060. Internal validation via repeated five-fold cross-validation gave a mean cross-validated R2 of 0.299 (SD of repeat-specific means, 0.011). Conclusions: In fetuses considered structurally normal on second-trimester assessment, aortic isthmus diameter was associated with gestational age, and, in addition, with aortic and pulmonary valve diameters, which accounted for a modest further share of the variance. No independent association with thymic diameter was demonstrated.
SN  - 2077-0383
ER  -