Peer-reviewedCC BY-NC-SAJournal of Medical Physics

Dosimetric Comparison of Functional Radiosurgery Treatments for Trigeminal Neuralgia, Essential Tremor, and Obsessive-compulsive Disorder Using Gamma Knife, CyberKnife, and Linear Accelerators

Abstract

Purpose: This study aims to evaluate and compare dose distribution for a trigeminal neuralgia (TN), essential tremor (ET), and obsessive-compulsive disorder (OCD) plan, using Gamma Knife (GK) Perfexion, CyberKnife (CK), and linear accelerators (linac) for a single treatment case. Materials and Methods: For all treatment platforms, plans utilized the same isocenter position and anatomical structures, with GK Perfexion plans as the reference. The prescribed doses were established at 90 Gy for TN, 140 Gy for ET, and 120 Gy for OCD. The irradiation geometry for each platform was defined to optimize the dose gradient vector in all directions. Dose distributions were evaluated both qualitatively and quantitatively. Dose profiles were extracted from axial and coronal plans to assess and compare the full width at half maximum (FWHM) and the penumbra size. Doses to normal tissue were compared, and the gradient index (GI) was used to evaluate the dose fall-off. Results: Dose distribution from CK and linac closely imitated GK Perfexion. The maximum difference for FWHM and penumbra was 2.1 mm and 1.3 mm, respectively, for the TN plans, with linac producing steeper dose gradients than GK Perfexion. The GI, in turn, was significantly different for the CK ET plan, with a value of 5.4 compared to 3.8 for GK Perfexion and linac. This difference did not have a clinical impact, as the dose to normal tissue was within tolerance. Conclusions: All platforms provided appropriate dose distribution and dose constraints.

Related

  1. Geometric and dosimetric effects of an automated clustering and plan optimization pipeline for multiple brain metastasis radiosurgery.
    Adam D Yock, Guozhen Luo, Sean All +2
    Journal of applied clinical medical physicsPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
  2. Dosimetric and Treatment Delivery Efficiency Comparison of Two Ring-gantry Linear Accelerator Platforms for Liver Stereotactic Body Radiotherapy
    Srikanth Guduru, Rohith Singareddy, N. V. N. Madhusudhana Sresty +2
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
  3. Dosimetric Comparison of Intensity-Modulated Radiotherapy and Four-Field Three-Dimensional Conformal Radiotherapy in the Management of Prostate Cancer: A Retrospective Dual-Centre Analysis
    Alaa AbdAllah, wafaa mohamed, Amani Saber +1
    Minia Journal of Medical ResearchPeer-reviewedCC BYFull textApplied physics & instrumentationDOAJ
  4. Dosimetric feasibility of lattice radiotherapy for bulky tumors: a paired VMAT vs. helical tomotherapy comparison - the STRYKE trial
    Mottareale R, Serra M, Pezzulla D +18
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossref
  5. In Silico Dosimetric Comparison of Intensity-Modulated Photon Versus Proton Therapy for Pelvic and Para-Aortic Nodal Recurrence of Prostate Cancer Following Prior Irradiation
    James A. Knight, Hao Chen, Anh Tran +9
    CancersPeer-reviewedCC BY 4.0Applied physics & instrumentationCrossref
BibTeX
@article{venencia2026dosimetric,
  title = {{Dosimetric Comparison of Functional Radiosurgery Treatments for Trigeminal Neuralgia, Essential Tremor, and Obsessive-compulsive Disorder Using Gamma Knife, CyberKnife, and Linear Accelerators}},
  author = {Carlos Daniel Venencia and Crystian Wilian Chagas Saraiva and Gabriela Reis dos Santos de Jesus},
  journal = {Journal of Medical Physics},
  year = {2026},
  month = jul,
  doi = {10.4103/jmp.jmp_17_26},
  url = {https://doi.org/10.4103/jmp.jmp_17_26},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - Dosimetric Comparison of Functional Radiosurgery Treatments for Trigeminal Neuralgia, Essential Tremor, and Obsessive-compulsive Disorder Using Gamma Knife, CyberKnife, and Linear Accelerators
AU  - Carlos Daniel Venencia
AU  - Crystian Wilian Chagas Saraiva
AU  - Gabriela Reis dos Santos de Jesus
PY  - 2026
DA  - 2026/07/01
JO  - Journal of Medical Physics
DO  - 10.4103/jmp.jmp_17_26
UR  - https://doi.org/10.4103/jmp.jmp_17_26
AB  - Purpose: This study aims to evaluate and compare dose distribution for a trigeminal neuralgia (TN), essential tremor (ET), and obsessive-compulsive disorder (OCD) plan, using Gamma Knife (GK) Perfexion, CyberKnife (CK), and linear accelerators (linac) for a single treatment case. Materials and Methods: For all treatment platforms, plans utilized the same isocenter position and anatomical structures, with GK Perfexion plans as the reference. The prescribed doses were established at 90 Gy for TN, 140 Gy for ET, and 120 Gy for OCD. The irradiation geometry for each platform was defined to optimize the dose gradient vector in all directions. Dose distributions were evaluated both qualitatively and quantitatively. Dose profiles were extracted from axial and coronal plans to assess and compare the full width at half maximum (FWHM) and the penumbra size. Doses to normal tissue were compared, and the gradient index (GI) was used to evaluate the dose fall-off. Results: Dose distribution from CK and linac closely imitated GK Perfexion. The maximum difference for FWHM and penumbra was 2.1 mm and 1.3 mm, respectively, for the TN plans, with linac producing steeper dose gradients than GK Perfexion. The GI, in turn, was significantly different for the CK ET plan, with a value of 5.4 compared to 3.8 for GK Perfexion and linac. This difference did not have a clinical impact, as the dose to normal tissue was within tolerance. Conclusions: All platforms provided appropriate dose distribution and dose constraints.
SN  - 0971-6203
SN  - 1998-3913
ER  -