Voltammetric determination of hydroxylamine using zinc ferrite nanoparticles/Mn(III) salen-doped carbon paste electrode
4 affiliations
- 1Chemistry Department, College of Science, Mustansiriyah University, Baghdad, Iraq
- 2Polymer Research Unit, College of Science, Mustansiriyah University, Baghdad, Iraq
- 3College of Engineering, Al-Iraqia University, Baghdad, Iraq
- 4Scientific Research Commission, Baghdad, Iraq
Abstract
Modification of carbon paste electrode (CPE) with ZnFe2O4 nanoparticles and Mn(III) salen (ZFO/salen/CPE) and its application in the measurement of hydroxylamine (HX) are the topics of this work. Differential pulse voltammetry, chronoamperometry and cyclic voltammetry (CV) were used in the investigations of the ZFO/salen/CPE for the electrochemical analysis of hydroxylamine. Because of the synergistic effect of the Mn(III) salen and ZnFe2O4 nanoparticles, the CV analyses showed improved catalytic behaviour of ZFO/salen/CPE toward the electrochemical reaction of HX. The linear range and HX detection limit were found to be 50 nM to 0.30 mM and 20 nM, respectively, using SWV. Long-term stability and reproducibility were demonstrated by this sensor. To confirm the sensor's appropriateness for use, HX measurement in water samples was carried out.
Related
- GO/Cysteamine-Modified Screen-Printed Carbon Electrode for Square-Wave Anodic Stripping Voltammetric Determination of Cadmium in Fortified Mango and Avocado Digestates.
- Modification of screen-printed carbon electrode with 2D MoS2 nanosheets/1D Bi2S3 nanorods heterostructures as voltammetric sensing platform for 2,4-dichlorophenol analysis in water samples
- Comparative Magnetic Heating of Surface-Modified Ferrite Nanoparticles in Water and Agar Phantoms
- Optimising the magnetic performance of Co ferrite nanoparticles via organic ligand capping
- Chemical engineering of cationic distribution in spinel ferrite nanoparticles: the effect on the magnetic properties
BibTeX
@article{dadoosh2026voltammetric,
title = {{Voltammetric determination of hydroxylamine using zinc ferrite nanoparticles/Mn(III) salen-doped carbon paste electrode}},
author = {Rasha M. Dadoosh and Athraa H. Oraibi and Noor Faraj Kadhem and Sabaa Abd Jaber and Muntaha Harjan Elewi},
journal = {Journal of Electrochemical Science and Engineering},
year = {2026},
month = nov,
doi = {10.5599/jese.3648},
url = {https://doi.org/10.5599/jese.3648},
note = {CC BY},
}
RIS
TY - JOUR
TI - Voltammetric determination of hydroxylamine using zinc ferrite nanoparticles/Mn(III) salen-doped carbon paste electrode
AU - Rasha M. Dadoosh
AU - Athraa H. Oraibi
AU - Noor Faraj Kadhem
AU - Sabaa Abd Jaber
AU - Muntaha Harjan Elewi
PY - 2026
DA - 2026/11/01
JO - Journal of Electrochemical Science and Engineering
DO - 10.5599/jese.3648
UR - https://doi.org/10.5599/jese.3648
AB - Modification of carbon paste electrode (CPE) with ZnFe2O4 nanoparticles and Mn(III) salen (ZFO/salen/CPE) and its application in the measurement of hydroxylamine (HX) are the topics of this work. Differential pulse voltammetry, chronoamperometry and cyclic voltammetry (CV) were used in the investigations of the ZFO/salen/CPE for the electrochemical analysis of hydroxylamine. Because of the synergistic effect of the Mn(III) salen and ZnFe2O4 nanoparticles, the CV analyses showed improved catalytic behaviour of ZFO/salen/CPE toward the electrochemical reaction of HX. The linear range and HX detection limit were found to be 50 nM to 0.30 mM and 20 nM, respectively, using SWV. Long-term stability and reproducibility were demonstrated by this sensor. To confirm the sensor's appropriateness for use, HX measurement in water samples was carried out.
SN - 1847-9286
ER -