Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 44 min ago
PreprintarXiv licencearXiv

A Cryogenic Geophone with stable response from Room Temperature to millikelvin

Abstract

With the development of pulse-tube cryocoolers, the availability and use of low-temperature environments have increased exponentially in recent years. However, replacing liquid helium with a mechanical cooling device has, since its introduction, highlighted the need to attenuate the mechanical vibrations generated by the cryocooler itself. In the case of dilution refrigerators, which are capable of reaching temperatures on the order of few mK, the issue of mechanical vibrations reaching the experimental setup is, in many situations, extremely critical. This has led to the development of several customized experimental approaches aimed at attenuating vibrations. However, the inertial measurement of vibrations at cryogenic and, in particular, ultracryogenic temperatures has relied on customized sensors, since no commercially available, calibrated instruments exist for measurements at these temperatures. Nevertheless, many research groups employ commercial geophones that are recalibrated at low temperatures. This approach, however, is not free from systematic errors and presents significant challenges in quantitatively assessing the absolute response. In this work, we describe the development of cryogenic geophones exhibiting an almost temperature-independent response, from room temperature down to approximately 10 mK.

Related

  1. Optimising Cryogenic Wiring for Microwave-frequency Millikelvin Quantum Processors
    Adrien Di Lonardo, Giorge Gemisis, Juan Pablo Dehollain +1
    arXivPreprintCC BY-SA 4.0Full textQuantum physics & quantum informationarXiv
  2. Multi-Branch Transport in a Back-gated WS2 Transistor at Deep-Cryogenic Temperature
    Megan Powell, Vilas Patil, Hazel Neill +5
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationCondensed matterarXiv
  3. Demonstration of a cryogenic, switchable electron source for low-temperature detector calibration
    D. A. Bennett, M. Borghesi, P. Campana +17
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  4. Comparative Optical Spectroscopy of Er3+, Tm3+, and Eu3+ Molecular Complexes at Cryogenic Temperature
    Farhad Rasekh, Sahil, Arsalan Mansourzadeh +4
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  5. An Open Access Database of Power Diode Characteristics at Cryogenic Temperature
    Yasmine Baazizi, Ana Luiza Haas Bezerra, Alma Lemansour +4
    IET Electric Power ApplicationsPeer-reviewedCC BYCondensed matterHAL
BibTeX
@misc{pirro2026cryogenic,
  title = {{A Cryogenic Geophone with stable response from Room Temperature to millikelvin}},
  author = {Stefano Pirro and Marco Ricci and Simone Cioccolini},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.05101},
  eprint = {2610.05101},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.05101},
}
RIS
TY  - UNPB
TI  - A Cryogenic Geophone with stable response from Room Temperature to millikelvin
AU  - Stefano Pirro
AU  - Marco Ricci
AU  - Simone Cioccolini
PY  - 2026
DA  - 2026/10/04
PB  - arXiv
DO  - 10.48550/arxiv.2610.05101
UR  - https://arxiv.org/abs/2610.05101
AB  - With the development of pulse-tube cryocoolers, the availability and use of low-temperature environments have increased exponentially in recent years. However, replacing liquid helium with a mechanical cooling device has, since its introduction, highlighted the need to attenuate the mechanical vibrations generated by the cryocooler itself. In the case of dilution refrigerators, which are capable of reaching temperatures on the order of few mK, the issue of mechanical vibrations reaching the experimental setup is, in many situations, extremely critical. This has led to the development of several customized experimental approaches aimed at attenuating vibrations. However, the inertial measurement of vibrations at cryogenic and, in particular, ultracryogenic temperatures has relied on customized sensors, since no commercially available, calibrated instruments exist for measurements at these temperatures. Nevertheless, many research groups employ commercial geophones that are recalibrated at low temperatures. This approach, however, is not free from systematic errors and presents significant challenges in quantitatively assessing the absolute response. In this work, we describe the development of cryogenic geophones exhibiting an almost temperature-independent response, from room temperature down to approximately 10 mK.
ER  -