Experimental evaluation of supplemental friction dampers for torsional control of step-terrace mountain isolated structures

4 affiliations
  1. 11School of Intelligent Construction and Civil Engineering, Luoyang Institute of Science and Technology, Luoyang 471023, China
  2. 22School of Architecture Engineering, Kunming University of Science and Technology, Kunming 650500, China3Mechanics Postdoctoral Research Station, Kunming University of Science and Technology, Kunming 650500, China
  3. 34College of Architecture and Civil Engineering, Kunming University, Kunming 650214, China
  4. 45Kunming Dongchuan District Construction Project Quality and Safety Supervision and Management Station, Kunming 654100, China

Abstract

Step-terrace mountain (STM) isolated structures are susceptible to torsional response when eccentricity exists in the isolation layers, owing to dropped stories, multi-level foundations, and discontinuous stiffness distribution. This study experimentally investigates the use of supplemental friction dampers for torsional mitigation in eccentric STM isolated structures. Shaking-table tests were conducted using a 1:10-scale reinforced concrete STM isolated structural model. Comparative tests were performed for isolated and isolation–damping configurations under different isolation-layer eccentricity cases and seismic intensity levels. Torsional rotation, torsional displacement ratio, and relative torsional effect were adopted to evaluate the control performance of the proposed system. The results show that the supplemental friction dampers reduced the torsional response of the STM isolated structure under all investigated eccentricity configurations. Across all three tested eccentricity configurations, the supplemental friction dampers consistently reduced torsional response, with the most pronounced mitigation observed in case 2. Under increasing seismic intensity, the isolation–damping structure consistently exhibited lower torsional response than the corresponding isolated structure, while the fundamental frequency remained nearly unchanged. The supplemental dampers therefore improved torsional control without noticeably altering the global dynamic characteristics of the isolation system. The tested damper configuration corresponded to a total friction capacity of ∼13% of the total isolation-system yield force, while its equivalent secant stiffness contribution was only about 3% of the total horizontal stiffness of the isolation system. These findings provide experimental evidence for the application of supplemental friction dampers in torsional control of eccentric STM isolated structures.

Related

  1. Herschel-Quincke filter-inspired periodic structures for suppression of dilation and torsional waves in elastic rods and shafts
    Stepan Avetisov, Sergey Sorokin, Adrien Pelat +1
    Journal of Sound and VibrationPeer-reviewedCC BYGeneral physicsHAL
  2. Identification of Local Elasto-Plastic Properties in Multi-Material Thin Aluminum Welded Structures through Experimental Methods, Modeling, and AI
    Arthur Thibault, Théo Dobrossy, Jean-François Witz +4
    Procedia Structural IntegrityPeer-reviewedCC BY-NC-NDGeneral physicsHAL
  3. Experimental evaluation of Kolmogorov's first similarity hypothesis for shear-dependent viscosity fluids
    Luciano Hergenreder, Serge Simoëns, Wernher Brevis
    arXivPreprintarXiv licenceFull textCondensed matterFluid dynamicsarXiv
  4. Experimental Evaluation of Passive Polarization Compensation Techniques for Fiber-Distributed Polarization-Entangled Photons
    Gayatri Thik, Amit Loyal, Srinivasan K +1
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  5. Self-adaptive transcranial ultrasound imaging using an effective skull model: experimental evaluation on a human skull at 3.15 MHz
    Damien Kuntz, Anthony Novell, Quentin Grimal +2
    Acta AcusticaPeer-reviewedCC BY 4.0Full textBiological & medical physicsHAL
BibTeX
@article{wu2026experimental,
  title = {{Experimental evaluation of supplemental friction dampers for torsional control of step-terrace mountain isolated structures}},
  author = {Zhanjing Wu and Zhong Tao and Longfei Zhang and Zhengjia Wu and Qiang Huang and Haisu Sun},
  journal = {AIP Advances},
  year = {2026},
  month = oct,
  doi = {10.1063/5.0353420},
  url = {https://doi.org/10.1063/5.0353420},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Experimental evaluation of supplemental friction dampers for torsional control of step-terrace mountain isolated structures
AU  - Zhanjing Wu
AU  - Zhong Tao
AU  - Longfei Zhang
AU  - Zhengjia Wu
AU  - Qiang Huang
AU  - Haisu Sun
PY  - 2026
DA  - 2026/10/23
JO  - AIP Advances
DO  - 10.1063/5.0353420
UR  - https://doi.org/10.1063/5.0353420
AB  - Step-terrace mountain (STM) isolated structures are susceptible to torsional response when eccentricity exists in the isolation layers, owing to dropped stories, multi-level foundations, and discontinuous stiffness distribution. This study experimentally investigates the use of supplemental friction dampers for torsional mitigation in eccentric STM isolated structures. Shaking-table tests were conducted using a 1:10-scale reinforced concrete STM isolated structural model. Comparative tests were performed for isolated and isolation–damping configurations under different isolation-layer eccentricity cases and seismic intensity levels. Torsional rotation, torsional displacement ratio, and relative torsional effect were adopted to evaluate the control performance of the proposed system. The results show that the supplemental friction dampers reduced the torsional response of the STM isolated structure under all investigated eccentricity configurations. Across all three tested eccentricity configurations, the supplemental friction dampers consistently reduced torsional response, with the most pronounced mitigation observed in case 2. Under increasing seismic intensity, the isolation–damping structure consistently exhibited lower torsional response than the corresponding isolated structure, while the fundamental frequency remained nearly unchanged. The supplemental dampers therefore improved torsional control without noticeably altering the global dynamic characteristics of the isolation system. The tested damper configuration corresponded to a total friction capacity of ∼13% of the total isolation-system yield force, while its equivalent secant stiffness contribution was only about 3% of the total horizontal stiffness of the isolation system. These findings provide experimental evidence for the application of supplemental friction dampers in torsional control of eccentric STM isolated structures.