Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 16 min ago
PreprintCC BYmedRxiv

Foundation Model Artificial Intelligence for Electrocardiogram Detection of Rheumatic Mitral Stenosis

  1. 1University of Michigan

Abstract

BackgroundRheumatic mitral stenosis (RMS) disproportionately affects low-resource settings where echocardiography is limited. We evaluated foundation model (FM) feasibility for RMS detection using limited, indirectly labeled ECGs.

MethodsAn ECG-FM was fine-tuned using 804 RMS-positive ECGs per fold and externally validated across clinical and wearable lead configurations.

ResultsInternal AUROCs were 0.89, 0.87, and 0.87, for 12-Lead, 6-Lead, and 1-Lead respectively. External AUROCs were 0.82, 0.80, and 0.77. Performance remained comparable across demographic subgroups.

ConclusionsFM fine-tuning enables RMS detection using limited ICD-derived labels, supporting further evaluation of reduced-lead ECG screening and echocardiography triage in resource-constrained settings.

Related

  1. Artificial Intelligence-Enabled Electrocardiogram Screening for Detection of Low Ejection Fraction in Routine Care: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.
    Ali Abdelhaleem Omar Ahmed, Omer Abdalhaleem Omer Ahmed, Rana Abdelhaleem Omar Ahmed +6
    Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, IncPeer-reviewedCC BYFull textCardiovascular medicineEurope PMCPMC
  2. External validation of artificial intelligence-guided electrocardiogram (AI-ECG) in detecting asymptomatic left ventricular dysfunction: A systematic review and meta-analysis
    Jacky Chen, Thomas H Marwick, Cheng Hwee Soh
    American journal of preventive cardiologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Hypertrophic cardiomyopathy phenotype is associated with postmyectomy change in diastolic function measured by artificial intelligence-enabled electrocardiogram.
    Julia G Debertin, Hartzell V Schaff, Masoomeh Aslahishahri +9
    JTCVS openPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMCPMC
  4. Artificial Intelligence-Driven Nanobody Engineering for Pathogen Recognition: From Functional Epitope Prioritization to Multimodal Foundation Models
    Rui-Si Hu, Muhammad Ehsan, Wei Luo +5
    BiomoleculesPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyCrossrefEurope PMC
  5. Advances in Multimodal Artificial Intelligence in Radiology: Data Integration, Foundation Models, and Clinical Applications-A Narrative Review.
    Ghada Alfattni
    Healthcare (Basel, Switzerland)Peer-reviewedCC BYFull textEpidemiology & public healthEurope PMC
BibTeX
@misc{sriram2026foundation,
  title = {{Foundation Model Artificial Intelligence for Electrocardiogram Detection of Rheumatic Mitral Stenosis}},
  author = {R. Sriram and I. Nenadic and Z. Loring and M. Fudim and A. Mazella and A. K. Gehi and V. L. Murthy},
  howpublished = {medRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.12.26365300},
  url = {https://www.medrxiv.org/content/10.64898/2026.10.12.26365300v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Foundation Model Artificial Intelligence for Electrocardiogram Detection of Rheumatic Mitral Stenosis
AU  - R. Sriram
AU  - I. Nenadic
AU  - Z. Loring
AU  - M. Fudim
AU  - A. Mazella
AU  - A. K. Gehi
AU  - V. L. Murthy
PY  - 2026
DA  - 2026/10/12
PB  - medRxiv
DO  - 10.64898/2026.10.12.26365300
UR  - https://www.medrxiv.org/content/10.64898/2026.10.12.26365300v1
AB  - BackgroundRheumatic mitral stenosis (RMS) disproportionately affects low-resource settings where echocardiography is limited. We evaluated foundation model (FM) feasibility for RMS detection using limited, indirectly labeled ECGs.  MethodsAn ECG-FM was fine-tuned using 804 RMS-positive ECGs per fold and externally validated across clinical and wearable lead configurations.  ResultsInternal AUROCs were 0.89, 0.87, and 0.87, for 12-Lead, 6-Lead, and 1-Lead respectively. External AUROCs were 0.82, 0.80, and 0.77. Performance remained comparable across demographic subgroups.  ConclusionsFM fine-tuning enables RMS detection using limited ICD-derived labels, supporting further evaluation of reduced-lead ECG screening and echocardiography triage in resource-constrained settings.
ER  -