A Dietary Feature-Integrated Non-Invasive Corneal Autofluorescence System for Systemic AGE Assessment.
5 affiliations
- 1School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China.
- 2Guangxi Academy of Artificial Intelligence, Nanning 530000, China.
- 3Nanning Guidian Electronic Technology Research Institute Co., Ltd., Nanning 530000, China.
- 4Infection Management Department, The First Affiliated Hospital of Guangdong Pharmaceutical University, Guangzhou 510080, China.
- 5Department of Urology, The First Affiliated Hospital of Jinan University, Guangzhou 510630, China.
Abstract
Current clinical indicators for diabetes management are limited by the invasiveness of conventional measurements and their inability to capture metabolic memory, highlighting the need for reliable biomarkers for long-term metabolic status assessment. Advanced glycation end products (AGEs) accumulate progressively in corneal tissues. In this study, a portable AGE detection system based on corneal autofluorescence was developed. To enhance the acquisition capability of weak fluorescence signals, the system integrated a silicon photomultiplier (SiPM) with a dual-phase lock-in amplification technique. Multiple regression models were established using clinical data from 300 participants, with dietary factors incorporated as additional input features. Among them, serum AGE measurements from 104 participants were used as reference values. The Random Forest Regression model exhibited the best predictive performance, with approximately 85% of samples showing absolute relative prediction errors below 5%, a mean absolute percentage error of 3.8%, and a maximum relative error of 12.01%. Longitudinal monitoring further demonstrated that prediction errors were below 7% at three of the four time points, while the error at Day 0 was 10.77%. These findings suggest that the proposed system can provide relatively accurate and stable estimates of serum AGE concentrations and may have potential for supporting for long-term diabetes monitoring and early screening.
Related
- Non-invasive assessment of estimated glomerular filtration rate using lens autofluorescence in a population without chronic kidney disease
- Integrated imaging, body composition, and systemic immune-inflammatory profiling for non-invasive prediction of HER2 status in endometrial cancer
- Endoscopic NIRAF-LSCI multimodal system with pseudo-color visualization for parathyroid autofluorescence localization and tissue perfusion assessment: preclinical validation
- 124 Integrated single-cell transcriptomic profiling of urine-derived cells as a strategy for non-invasive therapeutic monitoring in bladder cancer
- EP05.19 Integrated analysis of systemic inflammatory indices and post-treatment radiomics in glioblastoma: a multidimensional paradigm for prognostic stratification
BibTeX
@article{zhu2026dietary,
title = {{A Dietary Feature-Integrated Non-Invasive Corneal Autofluorescence System for Systemic AGE Assessment.}},
author = {Jianming Zhu and Qirui Yang and Huadang Meng and Jinghui Lu and Hong Ling and Zhencheng Chen and Baoli Heng},
journal = {Biosensors},
year = {2026},
month = oct,
doi = {10.3390/bios16110598},
url = {https://europepmc.org/article/MED/43082493},
note = {CC BY},
}
RIS
TY - JOUR
TI - A Dietary Feature-Integrated Non-Invasive Corneal Autofluorescence System for Systemic AGE Assessment.
AU - Jianming Zhu
AU - Qirui Yang
AU - Huadang Meng
AU - Jinghui Lu
AU - Hong Ling
AU - Zhencheng Chen
AU - Baoli Heng
PY - 2026
DA - 2026/10/23
JO - Biosensors
DO - 10.3390/bios16110598
UR - https://europepmc.org/article/MED/43082493
AB - Current clinical indicators for diabetes management are limited by the invasiveness of conventional measurements and their inability to capture metabolic memory, highlighting the need for reliable biomarkers for long-term metabolic status assessment. Advanced glycation end products (AGEs) accumulate progressively in corneal tissues. In this study, a portable AGE detection system based on corneal autofluorescence was developed. To enhance the acquisition capability of weak fluorescence signals, the system integrated a silicon photomultiplier (SiPM) with a dual-phase lock-in amplification technique. Multiple regression models were established using clinical data from 300 participants, with dietary factors incorporated as additional input features. Among them, serum AGE measurements from 104 participants were used as reference values. The Random Forest Regression model exhibited the best predictive performance, with approximately 85% of samples showing absolute relative prediction errors below 5%, a mean absolute percentage error of 3.8%, and a maximum relative error of 12.01%. Longitudinal monitoring further demonstrated that prediction errors were below 7% at three of the four time points, while the error at Day 0 was 10.77%. These findings suggest that the proposed system can provide relatively accurate and stable estimates of serum AGE concentrations and may have potential for supporting for long-term diabetes monitoring and early screening.
SN - 2079-6374
ER -