A Compact Single-Beam Optically Pumped Magnetometer Based on Absorption Detection

Abstract

We demonstrate a compact single-beam optically pumped magnetometer (OPM) employing a pure 87Rb microfabricated vapor cell with 500 Torr buffer gas. The residual magnetic field is actively minimized to below 400 pT through a combination of mu-metal magnetic shielding and internal compensation coils. We systematically characterize the OPM response as a function of laser detuning and optical intensity, and derive the magnetic-field sensitivity from the signal slope and noise amplitude spectral density. A best sensitivity of 11 fT/Hz^1/2 is achieved near the resonance transition at an optimal optical intensity, using a small cell volume of only 0.027 cm^3. Furthermore, a miniaturized OPM prototype was developed using a folded flexible printed circuit board (FPCB) to integrate the vapor cell, a compact heater, and magnetic-field coils into a cubic sensing head. Two coil configurations patterned directly on the FPCB were investigated. Under optimized operating conditions, the OPM prototype achieved a sensitivity of 66 fT/Hz^1/2. These results demonstrate that high-buffer-pressure single-beam OPMs can achieve excellent sensitivity, establishing a pathway toward compact and scalable arrays.

Related

  1. Optically Active Single Hole Spin in ZnSe
    Amirehsan Alizadehherfati, Yuxi Jiang, Kelsey J. Mirrielees +7
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  2. Absorption and Phase-Contrast Microtomography Using Direct X-Ray Detection With Commercial Off-The-Shelf CMOS Sensors
    Damian L. Corzi, Jose Lipovetzky, Fabricio Alcalde Bessia +5
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  3. Compact Single-Axis Optical Gyroscope Transceiver Based On Photonic Wire Bonding Technique
    tongtong yang, Xuejie Gao, Jie Chai +3
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Direct generation of a watt-level single-frequency vortex laser beam via annular pumping in a compact standing-wave cavity
    Zixuan Zhao, Minghao Guo, Xin Yan +5
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  5. Specific absorption rate of uniaxial single-domain nanomagnets: stochastic spin dynamics versus linear response theory
    H. Kachkachi
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
BibTeX
@misc{liou2026compact,
  title = {{A Compact Single-Beam Optically Pumped Magnetometer Based on Absorption Detection}},
  author = {Jia-You Liou and Yi-Hsuan Chen and Hsiang-An Chuang and Chih-Hsuan Huang and Zong-Hsin Liu and I-Chiao Tsai and Kai-Hsin Peng and Yi-Hsin Chen},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.32795},
  eprint = {2610.32795},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.32795},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - A Compact Single-Beam Optically Pumped Magnetometer Based on Absorption Detection
AU  - Jia-You Liou
AU  - Yi-Hsuan Chen
AU  - Hsiang-An Chuang
AU  - Chih-Hsuan Huang
AU  - Zong-Hsin Liu
AU  - I-Chiao Tsai
AU  - Kai-Hsin Peng
AU  - Yi-Hsin Chen
PY  - 2026
DA  - 2026/10/23
PB  - arXiv
DO  - 10.48550/arxiv.2610.32795
UR  - https://arxiv.org/abs/2610.32795
AB  - We demonstrate a compact single-beam optically pumped magnetometer (OPM) employing a pure 87Rb microfabricated vapor cell with 500 Torr buffer gas. The residual magnetic field is actively minimized to below 400 pT through a combination of mu-metal magnetic shielding and internal compensation coils. We systematically characterize the OPM response as a function of laser detuning and optical intensity, and derive the magnetic-field sensitivity from the signal slope and noise amplitude spectral density. A best sensitivity of 11 fT/Hz^1/2 is achieved near the resonance transition at an optimal optical intensity, using a small cell volume of only 0.027 cm^3. Furthermore, a miniaturized OPM prototype was developed using a folded flexible printed circuit board (FPCB) to integrate the vapor cell, a compact heater, and magnetic-field coils into a cubic sensing head. Two coil configurations patterned directly on the FPCB were investigated. Under optimized operating conditions, the OPM prototype achieved a sensitivity of 66 fT/Hz^1/2. These results demonstrate that high-buffer-pressure single-beam OPMs can achieve excellent sensitivity, establishing a pathway toward compact and scalable arrays.
ER  -