Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 44 min ago
Peer-reviewedCC BY 4.0Andrology

Comparative Outcomes of Early versus Delayed Penile Prosthesis Insertion in Patients With Ischaemic Priapism—Long‐Term Outcome Experience From a Single High‐volume Centre

6 affiliations
  1. 1The University of Hong Kong Hong Kong China
  2. 2King's College London London UK
  3. 3Department of Urology Chelsea and Westminster Hospital NHS Trust London UK
  4. 4Division of Surgery and Interventional Science University College London London UK
  5. 5The Institute of Andrology Department of Urology University College London Hospitals NHS Foundation Trust London UK
  6. 6National Institute for Health and Research University College London Hospitals, Biomedical Research Centre London UK

Abstract

Background and Objectives: Ischaemic priapism (IP) is a urological emergency that can lead to erectile dysfunction (ED) if not treated promptly. This study aims to evaluate and compare clinical outcomes between early and delayed penile prosthesis insertion in patients with IP.

Methods: This is a single centre retrospective observational study, which included 166 patients who underwent penile prosthesis surgery for refractory IP from 2006 to 2025. Data were collected through institutional databases.

Key Findings and Limitations: Early prosthesis insertion was performed in 112 patients, with a median time (IQR) to implantation of 10 (6–15) days. 54 patients underwent delayed insertion, with a median time of 270 (120–1460) days. In unadjusted analysis, patient satisfaction was higher in the early group (OR 2.93; 95% CI: 1.21–7.18); however, this became a non‐significant trend after multivariable adjustment for prosthesis type. Delayed implantation remained independently associated with higher odds of revision surgery after adjustment for prosthesis type (OR 3.74; 95% CI: 1.22–11.44) There were no statistically significant differences between reported penile shortening and post‐operative infection. Key limitations include the study's retrospective single‐centre design, differential follow‐up duration and the lack of a standardized questionnaire to assess patient satisfaction.

Interventions: Patients in both early and delayed group underwent penile prosthesis implantation, either a malleable or inflatable prosthesis was used.

Conclusions and Clinical Implications: The findings from this study highlight the importance of timely management of IP in clinical settings. Early penile prosthesis insertion is associated with lower revision risk and demonstrates a trend toward improved satisfaction. The findings support a proactive surgical approach towards patients with refractory IP, underscoring the importance of prompt management when conservative treatment fails.

Related

  1. Pharmacological thromboprophylaxis following ventriculoperitoneal shunt insertion: a single-centre experience of thromboembolic and bleeding outcomes
    Adnan R. Alnaser, Furkan Zurel, Abed Alnsour +5
    Acta NeurochirurgicaPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  2. Anterior Lumbar Interbody Fusion Versus Total Disc Replacement with a Viscoelastic Prosthesis for Single-Level Lumbar Degenerative Disc Disease in Young Adults: A Comparative Retrospective Cohort Study
    Clément Jacquemin, Matthieu Campana, Jean-Etienne Castelain +3
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Thrombophilic Variants and Clinical Outcomes in Young Ischaemic Stroke Patients Undergoing Mechanical Thrombectomy: A Retrospective Cohort Study
    Ebru Marzioglu Ozdemir, Gokhan Ozdemir
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. ITACARE-P cardiorehab registry: real-world data on quality and outcomes in heart failure and ischaemic heart disease - a prospective observational study protocol of the Italian early post-acute cardiac rehabilitation network.
    Fabiana I Gambarin, Gaia Coni, Raffaele Griffo +15
    BMJ openPeer-reviewedCC BY-NCFull textCardiovascular medicineEurope PMCCrossref
  5. Comparative host–graft biomechanics of osteoarticular allografts and allograft–prosthesis composites after distal femoral tumor resection
    Vasileios Apostolopoulos, Petr Boháč, Michal Mahdal +3
    Journal of Orthopaedic Surgery and ResearchPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaDOAJPMC
BibTeX
@article{tong2026comparative,
  title = {{Comparative Outcomes of Early versus Delayed Penile Prosthesis Insertion in Patients With Ischaemic Priapism—Long‐Term Outcome Experience From a Single High‐volume Centre}},
  author = {King Sum Tong and Karl H. Pang and Jerry T. Y. Lau and David J. Ralph and Asif Muneer and Hussain M. Alnajjar},
  journal = {Andrology},
  year = {2026},
  month = jul,
  doi = {10.1111/andr.70309},
  url = {https://doi.org/10.1111/andr.70309},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Comparative Outcomes of Early versus Delayed Penile Prosthesis Insertion in Patients With Ischaemic Priapism—Long‐Term Outcome Experience From a Single High‐volume Centre
AU  - King Sum Tong
AU  - Karl H. Pang
AU  - Jerry T. Y. Lau
AU  - David J. Ralph
AU  - Asif Muneer
AU  - Hussain M. Alnajjar
PY  - 2026
DA  - 2026/07/08
JO  - Andrology
DO  - 10.1111/andr.70309
UR  - https://doi.org/10.1111/andr.70309
AB  - Background and Objectives: Ischaemic priapism (IP) is a urological emergency that can lead to erectile dysfunction (ED) if not treated promptly. This study aims to evaluate and compare clinical outcomes between early and delayed penile prosthesis insertion in patients with IP.  Methods: This is a single centre retrospective observational study, which included 166 patients who underwent penile prosthesis surgery for refractory IP from 2006 to 2025. Data were collected through institutional databases.  Key Findings and Limitations: Early prosthesis insertion was performed in 112 patients, with a median time (IQR) to implantation of 10 (6–15) days. 54 patients underwent delayed insertion, with a median time of 270 (120–1460) days. In unadjusted analysis, patient satisfaction was higher in the early group (OR 2.93; 95% CI: 1.21–7.18); however, this became a non‐significant trend after multivariable adjustment for prosthesis type. Delayed implantation remained independently associated with higher odds of revision surgery after adjustment for prosthesis type (OR 3.74; 95% CI: 1.22–11.44) There were no statistically significant differences between reported penile shortening and post‐operative infection. Key limitations include the study's retrospective single‐centre design, differential follow‐up duration and the lack of a standardized questionnaire to assess patient satisfaction.  Interventions: Patients in both early and delayed group underwent penile prosthesis implantation, either a malleable or inflatable prosthesis was used.  Conclusions and Clinical Implications: The findings from this study highlight the importance of timely management of IP in clinical settings. Early penile prosthesis insertion is associated with lower revision risk and demonstrates a trend toward improved satisfaction. The findings support a proactive surgical approach towards patients with refractory IP, underscoring the importance of prompt management when conservative treatment fails.
SN  - 2047-2919
SN  - 2047-2927
ER  -