Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 56 min ago
Peer-reviewedCC BY-NC-SAJournal of Medical Physics

Automated Radiotherapy Planning for Head-and-neck Cancer: Multi-institutional Development, Validation, and Clinical Implementation of Monaco Scripting

Abstract

Purpose: The purpose of this study was to develop, validate, and clinically implement a standardized automated treatment planning framework using Monaco scripting and to evaluate its dosimetric performance, consistency, and organ-at-risk (OAR) sparing compared with conventional manual planning for head-and-neck cancer (HNC) across a multi-institutional network. Materials and Methods: A Pareto-based multi-criteria optimization template was iteratively developed, validated on >300 retrospective cases, and implemented across 14 centers. Forty-seven HNC patients were replanned using clinically approved plan (CA), AutoPlan (AP), and AutoPlan iteration (API) approaches and categorized into single-target (n = 11), two-target (n = 35), and three-target (n = 1) cohorts. Plan quality was analyzed in ProKnow using scorecard evaluation, boxplots, histograms, and scatter-plot correlations focusing on target coverage and doses to critical organs including brainstem, spinal cord, and bilateral parotids. Results: Automated workflows demonstrated superior consistency and OAR sparing compared with CA plans. AP achieved the highest overall scorecard performance, while API consistently produced the most stable dose distributions with lower variability and weaker correlations between PTV_High coverage and OAR doses. CA plans exhibited the widest dose variability and stronger OAR dose dependence. Clinically, the automated scripts achieved >70% automation and have been used in over 850 patients with minimal manual intervention. Conclusion: Automated Monaco scripting significantly improves plan quality, consistency, and OAR sparing in HNC radiotherapy, supporting routine clinical adoption – particularly of iterative API workflows – for standardized multi-center practice.

Related

  1. CBCT-based adaptive radiotherapy and automated radiotherapy decision-making systems: development and current status
    Shang Wang, Xin Wang
    Frontiers in oncologyPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMCCrossref
  2. Using artificial intelligence for clinical trial quality assurance in a multi-institutional neurovascular-sparing prostate radiotherapy trial
    Matthew Doucette, Ying Zhang, Chien-Yi Liao +10
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Applied physics & instrumentationCrossref
  3. Fully automated diaphragm segmentation on routine 2D-cine and 3D thoracic MRI: multireader validation
    Samia Boussouar, Alexiane Pasquier, Damien Vaurs +16
    European radiology experimentalPeer-reviewedCC BYFull textSystems & synthetic biologyMedical imaging & radiologyEurope PMCHAL
  4. Anthropomorphic phantom dosimetry and validation of 150–200 MeV very high-energy electron radiotherapy at CERN
    Fabio S. D’Andrea, Adam H. Aitkenhead, Robert Chuter +5
    Communications PhysicsPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossref
  5. Characterization and Validation of MicroDiamond Detectors in Patient-specific Quality Assurance of Magnetic Resonance-guided Stereotactic Radiotherapy
    Sanjana Choudhary, Chithra Krishnamoorthy, Radhakrishnan B. Nair +2
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
BibTeX
@article{anchineyan2026automated,
  title = {{Automated Radiotherapy Planning for Head-and-neck Cancer: Multi-institutional Development, Validation, and Clinical Implementation of Monaco Scripting}},
  author = {Pichandi Anchineyan and Yuvarajan Sankaran and H. Mahedran and Sam Skennet Das},
  journal = {Journal of Medical Physics},
  year = {2026},
  month = jul,
  doi = {10.4103/jmp.jmp_47_26},
  url = {https://doi.org/10.4103/jmp.jmp_47_26},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - Automated Radiotherapy Planning for Head-and-neck Cancer: Multi-institutional Development, Validation, and Clinical Implementation of Monaco Scripting
AU  - Pichandi Anchineyan
AU  - Yuvarajan Sankaran
AU  - H. Mahedran
AU  - Sam Skennet Das
PY  - 2026
DA  - 2026/07/01
JO  - Journal of Medical Physics
DO  - 10.4103/jmp.jmp_47_26
UR  - https://doi.org/10.4103/jmp.jmp_47_26
AB  - Purpose: The purpose of this study was to develop, validate, and clinically implement a standardized automated treatment planning framework using Monaco scripting and to evaluate its dosimetric performance, consistency, and organ-at-risk (OAR) sparing compared with conventional manual planning for head-and-neck cancer (HNC) across a multi-institutional network. Materials and Methods: A Pareto-based multi-criteria optimization template was iteratively developed, validated on >300 retrospective cases, and implemented across 14 centers. Forty-seven HNC patients were replanned using clinically approved plan (CA), AutoPlan (AP), and AutoPlan iteration (API) approaches and categorized into single-target (n = 11), two-target (n = 35), and three-target (n = 1) cohorts. Plan quality was analyzed in ProKnow using scorecard evaluation, boxplots, histograms, and scatter-plot correlations focusing on target coverage and doses to critical organs including brainstem, spinal cord, and bilateral parotids. Results: Automated workflows demonstrated superior consistency and OAR sparing compared with CA plans. AP achieved the highest overall scorecard performance, while API consistently produced the most stable dose distributions with lower variability and weaker correlations between PTV_High coverage and OAR doses. CA plans exhibited the widest dose variability and stronger OAR dose dependence. Clinically, the automated scripts achieved >70% automation and have been used in over 850 patients with minimal manual intervention. Conclusion: Automated Monaco scripting significantly improves plan quality, consistency, and OAR sparing in HNC radiotherapy, supporting routine clinical adoption – particularly of iterative API workflows – for standardized multi-center practice.
SN  - 0971-6203
SN  - 1998-3913
ER  -