Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 44 min ago
Peer-reviewedCC BY-NC-ND 4.0BMC Ophthalmology

Comparative visual outcomes of extended depth-of-focus intraocular lenses after cataract surgery: a Bayesian network meta-analysis

5 affiliations
  1. 1Department of Ophthalmology, Tri-Service General Hospital, Taipei, Taiwan
  2. 2Department of Ophthalmology, College of Medicine, National Defense Medical University, No. 325, Sec. 2, Chenggong Rd., Neihu Dist., Taipei City 114, Taiwan
  3. 3Department of Ophthalmology, Show Chwan Memorial Hospital, Changhua, Taiwan
  4. 4Department of Medical Education, National Taiwan University Hospital, Taipei, Taiwan
  5. 5Department of Psychiatry, Beitou Branch, Tri-Service General Hospital, National Defense Medical University, No. 60, Xinmin Road, Beitou District, Taipei City 112, Taiwan

Abstract

Background: Extended depth-of-focus (EDOF) intraocular lenses (IOLs) are designed to enhance functional vision across distances while reducing dysphotopsia after cataract surgery. However, direct comparative evidence among different EDOF optical designs remains limited.

Methods: A systematic review and Bayesian network meta-analysis of randomized controlled trials was conducted. Embase, Ovid-Medline, and the Cochrane Central Register of Controlled Trials were searched from inception to February 24, 2024. Risk of bias was assessed using the Cochrane Risk of Bias 2.0 tool. Mean differences (MDs) with 95% credible intervals (CrIs) were estimated using a Bayesian random-effects model. Outcomes included visual acuity and patient-reported visual disturbances.

Results: Five randomized controlled trials involving 524 participants (1048 eyes) were included. For uncorrected distance visual acuity, IC-8 showed numerically more favorable estimates than LARA (MD = − 0.06 logMAR; 95% CrI − 0.21 to 0.08), SYMFONY (MD = − 0.06; 95% CrI − 0.18 to 0.06), and VIVITY (MD = − 0.07; 95% CrI − 0.20 to 0.06). For intermediate and near visual acuity, LARA showed numerically more favorable estimates among the lenses included in these analyses. However, most credible intervals crossed the null value, indicating substantial statistical uncertainty. Visual disturbance outcomes were summarized descriptively because of heterogeneous questionnaires and reporting formats.

Conclusions: This exploratory Bayesian network meta-analysis identified numerical trends among currently studied EDOF IOLs, but the available evidence does not establish the comparative superiority of any lens. The findings may inform cautious, individualized patient discussions and future research, while IOL selection should remain guided by patient-specific visual needs, ocular condition, tolerance of visual disturbances, and local accessibility.

Related

  1. Long-term visual outcomes and rotational stability of two diffractive toric intraocular lenses with different design combinations in cataract patients with long axial length
    Shuang Ni, Yongwei Zhou, Zhen Zhang +3
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Comparison of Visual and Ocular Hemodynamic Outcomes Following Trifocal vs Bifocal Intraocular Lens Implantation in Patients With Cataract and Myopia.
    Man Xu, Yan Shao, Xing Gao +1
    Medical science monitor : international medical journal of experimental and clinical researchPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Comparative Two-Year Outcomes of Three Different Three-Piece Intraocular Lenses in Flanged Intrascleral Fixation
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Comparison of clinical outcomes of trifocal versus extended depth of focus intraocular lenses: meta-analysis of randomized controlled trials
    Ji-guo Yu, Ting Ye, Yi Xiang
    BMC OphthalmologyPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  5. Multicenter evaluation of AI-based intraocular lens formulas and interpretable machine learning for cataract refractive prediction
    Ning Yang, Jiancheng Mu, Yi Liu +6
    Scientific ReportsPeer-reviewedCC BY 4.0Full textGeneral medicineCrossref
BibTeX
@article{yao2026comparative,
  title = {{Comparative visual outcomes of extended depth-of-focus intraocular lenses after cataract surgery: a Bayesian network meta-analysis}},
  author = {Ya-Hsin Yao and Shih-Heng Hung and Chiao-Hsin Lan and Da-Wen Lu and Ke-Hung Chien and Shu-I Pao and Chih-Sung Liang and Wei-Ting Yen},
  journal = {BMC Ophthalmology},
  year = {2026},
  month = aug,
  doi = {10.1186/s12886-026-05229-2},
  url = {https://doi.org/10.1186/s12886-026-05229-2},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Comparative visual outcomes of extended depth-of-focus intraocular lenses after cataract surgery: a Bayesian network meta-analysis
AU  - Ya-Hsin Yao
AU  - Shih-Heng Hung
AU  - Chiao-Hsin Lan
AU  - Da-Wen Lu
AU  - Ke-Hung Chien
AU  - Shu-I Pao
AU  - Chih-Sung Liang
AU  - Wei-Ting Yen
PY  - 2026
DA  - 2026/08/19
JO  - BMC Ophthalmology
DO  - 10.1186/s12886-026-05229-2
UR  - https://doi.org/10.1186/s12886-026-05229-2
AB  - Background: Extended depth-of-focus (EDOF) intraocular lenses (IOLs) are designed to enhance functional vision across distances while reducing dysphotopsia after cataract surgery. However, direct comparative evidence among different EDOF optical designs remains limited.  Methods: A systematic review and Bayesian network meta-analysis of randomized controlled trials was conducted. Embase, Ovid-Medline, and the Cochrane Central Register of Controlled Trials were searched from inception to February 24, 2024. Risk of bias was assessed using the Cochrane Risk of Bias 2.0 tool. Mean differences (MDs) with 95% credible intervals (CrIs) were estimated using a Bayesian random-effects model. Outcomes included visual acuity and patient-reported visual disturbances.  Results: Five randomized controlled trials involving 524 participants (1048 eyes) were included. For uncorrected distance visual acuity, IC-8 showed numerically more favorable estimates than LARA (MD = − 0.06 logMAR; 95% CrI − 0.21 to 0.08), SYMFONY (MD = − 0.06; 95% CrI − 0.18 to 0.06), and VIVITY (MD = − 0.07; 95% CrI − 0.20 to 0.06). For intermediate and near visual acuity, LARA showed numerically more favorable estimates among the lenses included in these analyses. However, most credible intervals crossed the null value, indicating substantial statistical uncertainty. Visual disturbance outcomes were summarized descriptively because of heterogeneous questionnaires and reporting formats.  Conclusions: This exploratory Bayesian network meta-analysis identified numerical trends among currently studied EDOF IOLs, but the available evidence does not establish the comparative superiority of any lens. The findings may inform cautious, individualized patient discussions and future research, while IOL selection should remain guided by patient-specific visual needs, ocular condition, tolerance of visual disturbances, and local accessibility.
SN  - 1471-2415
ER  -